Standard Operating Procedure for Lyophilization Process in Injectable Manufacturing


Department Sterile Injectable Manufacturing
SOP No. SOP/SIM/028/2025
Supersedes SOP/SIM/028/2022
Page No. Page 1 of 16
Issue Date 18/06/2025
Effective Date 20/06/2025
Review Date 18/06/2026

1. Purpose

To define the procedure for lyophilization (freeze-drying) of sterile injectable formulations to ensure product stability, integrity, and compliance with cGMP requirements during aseptic processing.

2. Scope

This SOP applies to all lyophilized sterile products manufactured in the Sterile Injectable

Manufacturing facility using validated lyophilizers.

3. Responsibilities

  • Production Operator: Loads/unloads vials, monitors process, records data in BMR.
  • Production Supervisor: Verifies parameters, ensures process compliance, signs BMR.
  • QA Officer: Provides line clearance, verifies process steps and documentation.
  • Engineering: Performs maintenance, calibration, and troubleshooting of lyophilizer.

4. Accountability

The Head – Production and Head – Quality Assurance are jointly accountable for adherence to the lyophilization process and compliance to regulatory standards.

5. Procedure

5.1 Preparation

  1. Ensure lyophilizer is cleaned and sterilized as per validated procedure.
  2. Verify the availability of the approved batch manufacturing record (BMR) and the product-specific lyophilization cycle parameters.
  3. Check and confirm the completion of vial filling and partial stoppering.

5.2 Loading the Vials

  1. Transfer partially stoppered vials from aseptic filling line to lyophilizer under LAF with QA clearance.
  2. Arrange vials on trays in a uniform manner, avoiding contact with chamber walls.
  3. Ensure the chamber door is sealed after loading and record loading details in Annexure-1.

5.3 Execution of Lyophilization Cycle

  1. Select the validated program on the lyophilizer HMI (Human-Machine Interface).
  2. Cycle stages typically include:
    • Freezing (-40°C to -50°C)
    • Primary Drying (sublimation under vacuum)
    • Secondary Drying (desorption at elevated temperature)
  3. Monitor chamber temperature, shelf temperature, condenser temperature, and vacuum levels throughout the cycle.
  4. Record all critical process parameters at defined intervals in Annexure-2.

5.4 Unloading and Final Stoppering

  1. Upon completion of the cycle, initiate the stoppering mechanism within the lyophilizer chamber.
  2. Break vacuum using sterile nitrogen or clean dry air as per product requirement.
  3. Unload the fully stoppered lyophilized vials using aseptic precautions and transfer to sealing area.
  4. Document unloading time, conditions, and operator name in Annexure-3.

5.5 Post-Run Cleaning and Maintenance

  1. Clean the lyophilizer chamber, trays, and associated components with validated cleaning agents.
  2. Dry all surfaces using sterile wipes and record cleaning details in Annexure-4.
  3. Ensure logbooks are updated and system is ready for the next batch.

6. Abbreviations

  • SOP: Standard Operating Procedure
  • BMR: Batch Manufacturing Record
  • LAF: Laminar Air Flow
  • QA: Quality Assurance
  • HMI: Human Machine Interface

7. Documents

  1. Lyophilizer Loading Record – Annexure-1
  2. Cycle Monitoring Log – Annexure-2
  3. Unloading Record – Annexure-3
  4. Lyophilizer Cleaning Log – Annexure-4

8. References

  • WHO GMP Guidelines for Sterile Products
  • ICH Q8 – Pharmaceutical Development
  • 21 CFR Part 211 – Current Good Manufacturing Practice

9. SOP Version

Version: 2.0

10. Approval Section

Prepared By Checked By Approved By
Signature
Date
Name
Designation Manufacturing Executive QA Executive Head QA
Department Production Quality Assurance Quality Assurance

11. Annexures

Annexure-1: Lyophilizer Loading Record

Date Batch No. No. of Vials Operator QA Checked By
18/06/2025 LYO-IV/025 20,000 Ajay Sharma Sunita Reddy

Annexure-2: Cycle Monitoring Log

Time Chamber Temp (°C) Shelf Temp (°C) Vacuum (mTorr) Operator Initial
10:00 -42 -40 180 AS
12:00 -20 -18 90 AS

Annexure-3: Unloading Record

Date Time Operator QA Verified By Remarks
19/06/2025 09:30 Vikas Nair Priya Joshi All vials intact

Annexure-4: Lyophilizer Cleaning Log

Date Cleaning Agent Cleaned By Verified By Remarks
19/06/2025 IPA 70% Rohit Desai QA Officer Clean and dry

Revision History

Revision Date Revision No. Details Reason Approved By
15/03/2022 1.0 Initial Release New SOP QA Head
18/06/2025 2.0 Updated procedure, annexures added Annual Review QA Head