Standard Operating Procedure for Intraosseous Injection Batch Manufacturing


Department Sterile Injectable Manufacturing
SOP No. SOP/SIM/024/2025
Supersedes SOP/SIM/024/2022
Page No. Page 1 of 14
Issue Date 18/06/2025
Effective Date 20/06/2025
Review Date 18/06/2026

1. Purpose

This SOP describes the step-by-step process for the batch manufacturing of intraosseous (IO) injection products under sterile conditions to ensure compliance with GMP, quality consistency, and regulatory expectations.

2. Scope

This SOP applies to all operations carried out for

intraosseous injection manufacturing at the sterile injectable manufacturing unit, including formulation, filtration, aseptic filling, in-process checks, and documentation.

3. Responsibilities

  • Manufacturing Executive: Responsible for executing manufacturing operations as per BMR.
  • Quality Assurance Executive: Ensures compliance and batch record verification.
  • Engineering Team: Responsible for equipment calibration and maintenance.
  • Microbiology: Monitors environmental parameters and sterility controls.

4. Accountability

The Head of Manufacturing is accountable for overall compliance, documentation, and review of manufacturing operations related to intraosseous injection batches.

5. Procedure

5.1 Pre-Manufacturing Preparation

  1. Ensure the designated cleanroom is cleaned, disinfected, and documented.
  2. Verify availability of raw materials, packaging materials, and utilities.
  3. Confirm equipment calibration and cleaning logs are complete and within validity.

5.2 Solution Preparation

  1. Transfer raw materials to manufacturing through dynamic pass box.
  2. Dissolve API and excipients in WFI inside a jacketed SS316L vessel equipped with stirrer.
  3. Maintain defined temperature and stirring rate to ensure homogenous mixture.
  4. Adjust pH if required and filter the solution through pre-filter (5 µm).

5.3 Sterile Filtration

  1. Filter the solution using sterile 0.22 µm membrane filter into a sterile filling vessel.
  2. Perform integrity testing (Bubble Point Test) pre and post filtration. Record in Annexure-2.
  3. Use sterile, single-use tubing systems or autoclaved connections to maintain sterility.

5.4 Aseptic Filling and Sealing

  1. Transfer sterile solution to aseptic filling area under Grade A conditions in LAF.
  2. Fill the IO solution into sterile containers/vials as per validated filling volume.
  3. Seal the vials with pre-sterilized rubber stoppers and aluminum seals.
  4. Visually inspect filled units for integrity, clarity, and absence of particulate matter (Annexure-3).

5.5 In-Process Quality Control

  1. Monitor and record temperature, differential pressure, and relative humidity.
  2. Perform in-process checks every 30 minutes for fill volume, clarity, sealing, and particulate matter.
  3. Document observations in Annexure-4: In-Process Quality Log.

5.6 Post-Manufacturing Activities

  1. Transfer vials to designated quarantine area with proper labeling.
  2. Clean all equipment as per SOP and record in equipment cleaning log.
  3. Submit BMR to QA for review and batch disposition.

6. Abbreviations

  • IO: Intraosseous
  • WFI: Water for Injection
  • BMR: Batch Manufacturing Record
  • QA: Quality Assurance
  • LAF: Laminar Air Flow

7. Documents

  1. Formulation Log – Annexure-1
  2. Filter Integrity Test Report – Annexure-2
  3. Visual Inspection Report – Annexure-3
  4. In-Process Quality Control Log – Annexure-4

8. References

  • ICH Q8: Pharmaceutical Development
  • WHO TRS No. 961: Annex 6
  • Schedule M (India): Good Manufacturing Practices

9. SOP Version

Version: 2.0

10. Approval Section

Prepared By Checked By Approved By
Signature
Date
Name Priya Natarajan Rakesh Jadhav Dr. Neha Menon
Designation Production Executive QA Executive Head QA
Department Manufacturing Quality Assurance Quality Assurance

11. Annexures

Annexure-1: Formulation Log

Date Batch No. Temp (°C) pH Operator
17/06/2025 IO/0625/01 22 6.5 Rajesh Kumar

Annexure-2: Filter Integrity Test Report

Filter ID Type Pre-Test Post-Test Status
FT-005 0.22 µm Pass Pass Accepted

Annexure-3: Visual Inspection Report

Unit No. Clarity Particles Seal Integrity Status
IO-0543 Clear Absent Intact Pass

Annexure-4: In-Process Quality Control Log

Time Volume (mL) Clarity Remarks Checked By
11:00 AM 2.0 Clear Compliant Sunita Reddy

Revision History

Revision Date Revision No. Details Reason Approved By
05/01/2022 1.0 Initial Issue New SOP QA Head
18/06/2025 2.0 Procedure and annexures updated Periodic Review QA Head