Standard Operating Procedure for Weighing of Raw Materials Under LAF in API Manufacturing

Department API Manufacturing
SOP No. SOP/API/015/2025
Supersedes SOP/API/015/2022
Page No. Page 1 of 10
Issue Date 13/04/2025
Effective Date 15/04/2025
Review Date 13/04/2026

1. Purpose

To define the procedure for weighing raw materials under Laminar Air Flow (LAF) to maintain accuracy, prevent cross-contamination, and ensure environmental control in accordance with GMP principles.

2. Scope

This SOP applies to the weighing of all raw materials used in API manufacturing that require controlled environmental conditions to ensure product quality and operator safety.

3. Responsibilities

4. Accountability

The Warehouse Manager is accountable for ensuring that weighing operations under LAF are performed correctly, recorded, and that equipment is validated and maintained.

5. Procedure

5.1 Pre-Weighing Checks

  1. Ensure the LAF unit is operational and cleaned as per its respective SOP.
  2. Switch ON the LAF and allow for a minimum of 15 minutes of air flow before initiating weighing.
  3. Verify that the area is clean and that cleaning status label is in place.
  4. Check the calibration status of the balance — calibration date must be current.
  5. Check raw material label for:
    • Name
    • Batch No.
    • Status (Approved)
    • Expiry Date

5.2 Weighing Procedure

  1. Wear appropriate PPE including gloves, mask, and clean room gown.
  2. Place a clean, pre-labeled container or liner on the balance.
  3. Tare the balance to zero.
  4. Using a clean scoop, slowly transfer the required quantity of material to the container.
  5. Ensure minimal dusting and avoid spilling by transferring at low height.
  6. Record the net weight and verify it against the material requisition.
  7. Once complete, close the container securely and affix “WEIGHED” label with:
    • Material Name
    • Batch No.
    • Weighed Quantity
    • Weighed By
    • Date & Time

5.3 Post-Weighing Activities

  1. Clean the balance and working surface with 70% IPA.
  2. Switch OFF the LAF after allowing for a 10-minute post-operation air flush.
  3. Return the excess material (if applicable) back to the original container and label as “PARTIAL.”
  4. Log the weighed material in the “Weighing Logbook” (Annexure-1).
  5. QA to cross-check the label and quantity before transferring material to the production staging area.

6. Abbreviations

7. Documents

  1. Weighing Logbook (Annexure-1)
  2. Balance Calibration Record (Annexure-2)
  3. LAF Cleaning Record (Annexure-3)

8. References

9. SOP Version

Version: 2.0

10. Approval Section

Prepared By Checked By Approved By
Signature
Date
Name
Designation
Department

11. Annexures

Annexure-1: Weighing Logbook

Date Material Batch No. Weighed Qty Weighed By Verified By
13/04/2025 API-123 AP202504 15 kg

Annexure-2: Balance Calibration Record

Date Balance ID Calibrated By Next Due Status
01/04/2025 BL-101 01/10/2025 Calibrated

Annexure-3: LAF Cleaning Record

Date LAF ID Cleaned By Verified By Remarks
12/04/2025 LAF-02 Cleaned & operational

Revision History:

Revision Date Revision No. Revision Details Reason for Revision Approved By
01/01/2022 1.0 Initial Issue GMP Compliance QA Head
13/04/2025 2.0 Added Post-Weighing Disinfection Step Audit Finding QA Head