Skip to content
  • Clinical Studies
  • Schedule M
  • Stability Studies
  • Pharma GMP
  • Pharma Tips
  • Pharma Books
  • Pharma Validation
  • Pharma Regulatory

SOP Guide for Pharma

The Ultimate Resource for Pharmaceutical SOPs and Best Practices

  • Home
  • SOP Guidelines
    • SOP Development
    • SOP Training
    • SOP Compliance Monitoring
    • SOP Revision Processes
    • Pharmaceutical SOP templates
    • GMP documentation SOP
    • Data integrity SOP pharma
    • Manufacturing SOP pharmaceutical
    • FDA SOP guidance
    • eQMS SOP workflows
  • Job Safety Analysis (JSA)
    • Oral Dosage Forms (Tablets & Capsules)
    • Oral Liquid Dosage Forms (Syrups, Elixirs, Suspensions, Emulsions)
    • Powder and Granule Dosage Forms
    • Topical Dosage Forms (Creams, Ointments, Gels, Lotions, Pastes)
    • Transdermal Dosage Forms (Patches)
  • Standard Test Procedures (STP)
  • GMP Audit Findings
    • Non-Compliance
      • SOP Absence
      • Revision Control
      • Non-Adherence
      • Poor Writing
      • Training Failure
      • Data Integrity Gaps
      • Mismatch Between SOPs and Practice
      • Critical Operations
      • Regulatory Change
      • Emergency Changes
      • Third-Party SOPs
      • Inspection Readiness
      • Deviation Handling
      • CAPA Integration
      • Validation Alignment
      • System Integration
      • Uncontrolled Distribution
      • SOP Implementation Gaps
      • SOP Alignment with Validation
      • Change Control Linkage
  • Toggle search form

API Manufacturing: SOP for Maintenance of Reagent Labeling and Logs – V 2.0

Posted on By

API Manufacturing: SOP for Maintenance of Reagent Labeling and Logs – V 2.0

Standard Operating Procedure for Maintenance of Reagent Labeling and Logs in API Manufacturing

Department API Manufacturing
SOP No. SOP/API/157/2025
Supersedes SOP/API/157/2022
Page No. Page 1 of 11
Issue Date 14/04/2025
Effective Date 16/04/2025
Review Date 14/04/2026

1. Purpose

To establish a standardized system for labeling and maintaining logs of reagents used in Quality Control (QC) laboratories involved in API manufacturing. The purpose is to ensure proper identification, traceability, usage tracking, and disposal of all reagents used in analytical testing.

2. Scope

This SOP applies to all chemical reagents, analytical grade solvents, acids,

bases, indicators, and special-purpose chemicals stored and used within the QC lab for routine testing and validation purposes.

3. Responsibilities

  • QC Analyst: Ensure proper labeling of reagents and make appropriate entries in reagent logs during receipt, preparation, and usage.
  • QC Store Assistant: Verify labels, manage storage, monitor expiry dates, and alert analysts for near-expiry reagents.
  • QC Supervisor: Review reagent logbooks and verify compliance with SOP requirements.

4. Accountability

The QC Head is accountable for maintaining reagent labeling, storage conditions, traceability, and ensuring that expired reagents are promptly removed from use.

See also  API Manufacturing: SOP for Audit Trail Review for GMP Systems - V 2.0

5. Procedure

5.1 Reagent Receipt and Labeling

  1. Upon receiving chemical reagents, inspect containers for:
    • Intact seal and packaging
    • Batch number and Certificate of Analysis (CoA)
    • Expiry date and storage condition
  2. Affix the internal QC label (Annexure-1) on the received reagent bottle, containing:
    • Name of reagent
    • Date of receipt and opening
    • Reagent ID number
    • Expiry date
    • Storage condition
    • Initials of person labeling
  3. Enter receipt details in the Reagent Master Register (Annexure-2).

5.2 Reagent Storage

  1. Store reagents based on the label’s recommended condition:
    • Ambient temperature
    • Refrigerated (2–8°C)
    • Light-sensitive (amber bottles)
  2. Maintain separation for:
    • Acids and bases
    • Oxidizers and reducing agents
    • Volatile solvents
  3. Clearly label and segregate expired reagents for disposal.

5.3 Reagent Preparation and Labeling

  1. Use only approved reagents listed in the Reagent Master Register for reagent preparation.
  2. During preparation, affix a freshly prepared reagent label (Annexure-3) with:
    • Prepared by (initials)
    • Preparation date and time
    • Concentration
    • Solvent used
    • Storage condition
    • Assigned reagent ID
    • Use before date
  3. Make entries in the Reagent Preparation Log (Annexure-4).

5.4 Usage and Expiry Tracking

  1. Each use of a reagent must be recorded in the Reagent Usage Log (Annexure-5) with:
    • Date
    • Reagent ID
    • Purpose of use
    • Initials
  2. QC Store Assistant must perform a monthly review of all reagents approaching expiry within 30 days.
  3. Expired reagents must be removed, marked “EXPIRED”, and transferred to the chemical disposal area.
See also  API Manufacturing: SOP for Tray Loading for Drying - V 2.0

5.5 Labeling Requirements

  1. Labels must be:
    • Legible and permanently affixed
    • Water and solvent resistant
    • Not handwritten unless for immediate use preparations
  2. Do not reuse containers or labels. Use fresh containers and labels for each new reagent preparation.

5.6 Disposal of Expired Reagents

  1. Fill the Expired Reagent Disposal Form (Annexure-6) and submit to QA.
  2. Disposal must be carried out in accordance with the chemical waste disposal SOP and local environmental laws.
  3. Maintain records of disposal for at least 5 years.

5.7 Audit and Review

  1. QA will perform quarterly audits of reagent logs, storage conditions, and labeling compliance.
  2. Any non-compliance will result in CAPA and training for relevant staff.

6. Abbreviations

  • QC: Quality Control
  • QA: Quality Assurance
  • CoA: Certificate of Analysis
  • CAPA: Corrective and Preventive Action

7. Documents

  1. Internal Reagent Label (Annexure-1)
  2. Reagent Master Register (Annexure-2)
  3. Prepared Reagent Label (Annexure-3)
  4. Reagent Preparation Log (Annexure-4)
  5. Reagent Usage Log (Annexure-5)
  6. Expired Reagent Disposal Form (Annexure-6)

8. References

  • ICH Q10 – Pharmaceutical Quality System
  • 21 CFR Part 211 – Subpart I: Laboratory Controls
  • WHO TRS No. 1019 – Annex 4: Good Practices for Quality Control Labs
See also  API Manufacturing: SOP for Documentation of In-Process Control Results - V 2.0

9. SOP Version

Version: 2.0

10. Approval Section

Prepared By Checked By Approved By
Signature
Date
Name
Designation
Department

11. Annexures

Annexure-1: Internal Reagent Label Format

Reagent Name Reagent ID Date of Receipt Expiry Storage Condition
Sulfuric Acid RG-2025-001 10/04/2025 10/04/2027 Ambient

Annexure-2: Reagent Master Register

Date Reagent Name Batch No. CoA Available Expiry Initials
10/04/2025 Sodium Hydroxide NAH25B03 Yes 10/04/2027 RK

Annexure-3: Prepared Reagent Label

Reagent Name Concentration Prepared On Use Before Prepared By
0.1N HCl 0.1N 12/04/2025 19/04/2025 SN

Annexure-4: Reagent Preparation Log

Date Reagent Name ID Concentration Prepared By Checked By
12/04/2025 0.1N NaOH RG-2025-008 0.1N SK PR

Annexure-5: Reagent Usage Log

Date Reagent ID Used For Initials
13/04/2025 RG-2025-008 LOD testing SR

Annexure-6: Expired Reagent Disposal Form

Reagent Name ID Expiry Date Disposed On Disposed By
Phenolphthalein RG-2023-115 01/04/2025 10/04/2025 QA

Revision History:

Revision Date Revision No. Details Reason Approved By
01/01/2022 1.0 Initial version System Implementation QA Head
14/04/2025 2.0 Integrated logs and disposal form Regulatory alignment QA Head
API Manufacturing V 2.0 Tags:API batch record, API BMR, API calibration, API centrifuge, API cleaning, API crystallization, API deviation, API documentation, API drying, API equipment cleaning, API filtration, API GMP compliance, API granulation, API hold time, API impurities, API line clearance, API manufacturing, API process, API quality control, API reactor, API sampling, API solvent handling, API validation, API waste disposal, API yield

Post navigation

Previous Post: Biosimilars: SOP for Tangential Flow Filtration (TFF) in Bioreactor Operations – V 2.0
Next Post: BA-BE Studies: SOP for Bioanalytical Sample Batch Preparation – V 2.0

Standard Operating Procedures V 1.0

  • Aerosols
  • Analytical Method Development
  • Bioequivalence Bioavailability Study
  • Capsule Formulation
  • Clinical Studies
  • Creams
  • Data Integrity
  • Dental Dosage Forms
  • Drug Discovery
  • Environment, Health and Safety
  • Formulation Development
  • Gels
  • Good Distribution Practice
  • Good Warehousing Practices
  • In-Process Control
  • Injectables
  • Liquid Orals
  • Liposome and Emulsion Formulations
  • Lotions
  • Lyophilized Products
  • Maintenance Dept.
  • Medical Devices
  • Metered-Dose Inhaler
  • Microbiology Testing
  • Nanoparticle Formulation
  • Nasal Spray Formulations
  • Nebulizers
  • Ocular (Eye) Dosage Forms
  • Ointments
  • Otic (Ear) Dosage Forms
  • Pharmacovigilance
  • Powder & Granules
  • Purchase Departments
  • Quality Assurance
  • Quality Control
  • Raw Material Stores
  • Regulatory Affairs
  • Tablet Manufacturing
  • Rectal Dosage Forms
  • Transdermal Patches
  • Vaginal Dosage Forms
  • Validations and Qualifications

Read SOPs in your Language:

 - 
Bengali
 - 
bn
English
 - 
en
Gujarati
 - 
gu
Hindi
 - 
hi
Malayalam
 - 
ml
Marathi
 - 
mr
Punjabi
 - 
pa
Tamil
 - 
ta
Telugu
 - 
te

NEW! Revised SOPs – V 2.0

  • Aerosols V 2.0
  • Analytical Method Development V 2.0
  • API Manufacturing V 2.0
  • BA-BE Studies V 2.0
  • Biosimilars V 2.0
  • Capsules V 2.0
  • Creams V 2.0
  • Elixers V 2.0
  • Gels V 2.0
  • Injectables V 2.0
  • Ointments V 2.0
  • Raw Material Warehouse V 2.0
  • Tablet Manufacturing V2.0

New Publication: A must for All.

Copyright © 2025 SOP Guide for Pharma.

Powered by PressBook WordPress theme

Go to mobile version