SOP Guide for Pharma

API Manufacturing: SOP for Isolation by Filtration – V 2.0

API Manufacturing: SOP for Isolation by Filtration – V 2.0

Standard Operating Procedure for Isolation by Filtration in API Manufacturing

Department API Manufacturing
SOP No. SOP/API/026/2025
Supersedes SOP/API/026/2022
Page No. Page 1 of 10
Issue Date 13/04/2025
Effective Date 15/04/2025
Review Date 13/04/2026

1. Purpose

To establish a standard procedure for the isolation of solid active pharmaceutical ingredients (APIs) or intermediates from liquid mixtures using filtration techniques, ensuring maximum yield, safety, and compliance with GMP.

2. Scope

This SOP applies to all batch processes requiring solid-liquid separation via filtration in the API manufacturing facility, including use of Nutsche filter, vacuum filter, or sparkler filter units.

3. Responsibilities

4. Accountability

The Production Manager and QA Manager are accountable for proper execution and compliance with filtration protocols.

5. Procedure

5.1 Equipment and Pre-Check

  1. Identify type of filtration equipment to be used (Nutsche, vacuum, sparkler).
  2. Ensure:
    • Cleanliness of filter vessel and internals
    • Filter cloth or paper is intact and properly installed
    • Gaskets and seals are leak-proof
    • Valves and pressure gauges are calibrated
  3. Record pre-operation checklist in “Filtration Equipment Inspection Log” (Annexure-1).

5.2 Filtration Process

  1. Transfer slurry or reaction mass to filtration vessel under gravity or pump transfer.
  2. Initiate filtration by:
    • Applying vacuum (for vacuum filter)
    • Using nitrogen blanketing or positive pressure (for Nutsche)
  3. Observe filtrate clarity at intervals. Continue until liquid passes clear.
  4. Record filtration start/end time and filter bed thickness.

5.3 Washing of Cake

  1. As per BMR, wash the solid mass with specified solvent.
  2. Add solvent to the vessel, agitate if required, and filter again.
  3. Repeat washing as per specified number of cycles or until filtrate meets quality parameters.

5.4 Discharge of Wet Cake

  1. Once filtration is complete, depressurize system (if pressurized).
  2. Open discharge valve and collect wet cake in labeled container or tray.
  3. Ensure complete transfer and minimal hold-up inside the vessel.
  4. Record quantity and send for drying or further processing.

5.5 Cleaning Post Operation

  1. Flush equipment with water or suitable solvent.
  2. Remove filter cloth for cleaning or replacement.
  3. Record cleaning status in “Equipment Cleaning Log.”

6. Abbreviations

7. Documents

  1. Filtration Equipment Inspection Log (Annexure-1)
  2. Filtration Process Logbook (Annexure-2)
  3. Wet Cake Collection Record (Annexure-3)

8. References

9. SOP Version

Version: 2.0

10. Approval Section

Prepared By Checked By Approved By
Signature
Date
Name
Designation
Department

11. Annexures

Annexure-1: Filtration Equipment Inspection Log

Date Equipment ID Filter Type Checked By Status Remarks
13/04/2025 NF-01 Nutsche Clean Ready for Use

Annexure-2: Filtration Process Logbook

Batch No. Start Time End Time Filtrate Clarity Washed? Operator
API-202504 10:00 12:15 Clear Yes (2x IPA)

Annexure-3: Wet Cake Collection Record

Date Batch No. Container ID Weight (kg) Transferred To Checked By
13/04/2025 API-202504 CT-22 18.5 Dryer-01

Revision History:

Revision Date Revision No. Revision Details Reason for Revision Approved By
01/01/2022 1.0 Initial Release New SOP QA Head
13/04/2025 2.0 Added Wet Cake Handling and Sparkler Usage Process Enhancement QA Head