Skip to content
  • Clinical Studies
  • Schedule M
  • Stability Studies
  • Pharma GMP
  • Pharma Tips
  • Pharma Books
  • Pharma Validation
  • Pharma Regulatory

SOP Guide for Pharma

The Ultimate Resource for Pharmaceutical SOPs and Best Practices

  • Home
  • SOP Guidelines
    • SOP Development
    • SOP Training
    • SOP Compliance Monitoring
    • SOP Revision Processes
    • Pharmaceutical SOP templates
    • GMP documentation SOP
    • Data integrity SOP pharma
    • Manufacturing SOP pharmaceutical
    • FDA SOP guidance
    • eQMS SOP workflows
  • Job Safety Analysis (JSA)
    • Oral Dosage Forms (Tablets & Capsules)
    • Oral Liquid Dosage Forms (Syrups, Elixirs, Suspensions, Emulsions)
    • Powder and Granule Dosage Forms
    • Topical Dosage Forms (Creams, Ointments, Gels, Lotions, Pastes)
    • Transdermal Dosage Forms (Patches)
  • Standard Test Procedures (STP)
  • GMP Audit Findings
    • Non-Compliance
      • SOP Absence
      • Revision Control
      • Non-Adherence
      • Poor Writing
      • Training Failure
      • Data Integrity Gaps
      • Mismatch Between SOPs and Practice
      • Critical Operations
      • Regulatory Change
      • Emergency Changes
      • Third-Party SOPs
      • Inspection Readiness
      • Deviation Handling
      • CAPA Integration
      • Validation Alignment
      • System Integration
      • Uncontrolled Distribution
      • SOP Implementation Gaps
      • SOP Alignment with Validation
      • Change Control Linkage
  • Toggle search form

API Manufacturing: SOP for Fire Extinguisher Inspection and Maintenance – V 2.0

Posted on By

API Manufacturing: SOP for Fire Extinguisher Inspection and Maintenance – V 2.0

Standard Operating Procedure for Fire Extinguisher Inspection and Maintenance in API Manufacturing

Department API Manufacturing
SOP No. SOP/API/204/2025
Supersedes SOP/API/204/2022
Page No. Page 1 of 13
Issue Date 14/04/2025
Effective Date 16/04/2025
Review Date 14/04/2026

1. Purpose

To establish a standardized procedure for monthly inspection, annual maintenance, refilling, tagging, and record-keeping of fire extinguishers installed in the API manufacturing facility. This ensures all firefighting equipment is in working condition and accessible during emergencies.

2. Scope

This SOP applies to all types of fire extinguishers located in the production, warehouse, utility areas, laboratories, corridors, and administrative

sections of the API manufacturing site. It includes CO₂, ABC, DCP, Foam, and Water-type extinguishers.

3. Responsibilities

  • Engineering/Maintenance Team: Conduct monthly inspections and ensure refilling and pressure checks are completed.
  • EHS Officer: Maintain fire extinguisher inventory and coordinate third-party annual maintenance.
  • QA Team: Audit compliance with fire safety SOPs and review inspection records.

4. Accountability

The Head of Engineering and Head of EHS are jointly accountable for ensuring that fire extinguishers are always maintained in a functional state and in compliance with fire safety regulations and internal policies.

See also  API Manufacturing: SOP for Mock Recall Procedure and Execution - V 2.0

5. Procedure

5.1 Fire Extinguisher Identification and Placement

  1. Each fire extinguisher shall be assigned a unique identification number (e.g., FE-API-001).
  2. Ensure extinguishers are:
    • Mounted at an accessible height (not exceeding 1.5 meters)
    • Free from obstructions
    • Located near potential fire hazards (machinery, solvent areas)
  3. Update the Fire Extinguisher Location Map (Annexure-1) after any relocation.

5.2 Monthly Visual Inspection

  1. Conducted by the Maintenance or EHS team using the Monthly Inspection Checklist (Annexure-2).
  2. Check the following parameters:
    • Pressure gauge (in green zone)
    • Nozzle and safety pin intact
    • External body free from corrosion or damage
    • Clear label and operating instructions
    • Inspection tag present and signed
  3. Tag the extinguisher after inspection with the month/year and inspector’s initials.

5.3 Annual Maintenance and Servicing

  1. Engage an authorized fire safety vendor to:
    • Open, refill, or recharge extinguishers as applicable
    • Replace faulty valves, pipes, and O-rings
    • Check weight of CO₂ extinguishers
  2. Vendor must provide a Fire Extinguisher Servicing Report (Annexure-3).

5.4 Recharging and Replacement Criteria

  1. Extinguishers must be recharged or replaced if:
    • Pressure is below recommended level
    • Seal or pin is broken
    • Used even partially during an incident
    • Expired per manufacturer’s instructions
  2. Dispose of expired or damaged extinguishers via authorized scrap vendor as per SOP/API/203/2025.
See also  API Manufacturing: SOP for Cleaning and Shutdown of QC Equipment - V 2.0

5.5 Record Keeping

  1. Maintain the Fire Extinguisher Master Register (Annexure-4) with the following:
    • Extinguisher ID
    • Type and capacity
    • Location
    • Inspection and servicing history
  2. Inspection reports must be signed and archived for a minimum of 5 years.

5.6 Mock Drill Coordination

  1. QA and EHS must ensure use of one extinguisher during quarterly mock fire drills for training purposes.
  2. Replace the used unit immediately and update the logbook accordingly.

5.7 Tagging Protocol

  1. Use color-coded inspection tags (green, yellow, red) to indicate:
    • Green – Recently inspected and in good condition
    • Yellow – Due for refilling
    • Red – Out of order
  2. Tag details must match the Fire Extinguisher Tag Format (Annexure-5).

6. Abbreviations

  • EHS: Environment, Health & Safety
  • CO₂: Carbon Dioxide
  • ABC: Multipurpose Dry Chemical
  • DCP: Dry Chemical Powder
  • SOP: Standard Operating Procedure

7. Documents

  1. Fire Extinguisher Location Map – Annexure-1
  2. Monthly Inspection Checklist – Annexure-2
  3. Fire Extinguisher Servicing Report – Annexure-3
  4. Fire Extinguisher Master Register – Annexure-4
  5. Fire Extinguisher Tag Format – Annexure-5
See also  API Manufacturing: SOP for Phase Separation Techniques - V 2.0

8. References

  • National Building Code of India – Part 4 (Fire and Life Safety)
  • NFPA 10 – Standard for Portable Fire Extinguishers
  • Factory Act, 1948 – Safety Provisions
  • Fire Services Department Guidelines (State-specific)

9. SOP Version

Version: 2.0

10. Approval Section

Prepared By Checked By Approved By
Signature
Date
Name
Designation
Department

11. Annexures

Annexure-1: Fire Extinguisher Location Map

A floor-wise site map indicating each fire extinguisher ID and type with assembly point markings.

Annexure-2: Monthly Inspection Checklist

Extinguisher ID Type Pressure Seal Intact Tag Updated Remarks
FE-API-001 CO₂ OK Yes Apr-25 —

Annexure-3: Fire Extinguisher Servicing Report

ID Type Service Date Vendor Next Due
FE-API-003 ABC 10/04/2025 FireSecure Ltd. 10/04/2026

Annexure-4: Fire Extinguisher Master Register

ID Location Type Capacity Install Date Last Inspection
FE-API-005 Warehouse Entry Foam 9 L 01/06/2023 01/04/2025

Annexure-5: Fire Extinguisher Tag Format

Month Year Inspected By Remarks
April 2025 Rajesh Kumar OK

Revision History:

Revision Date Revision No. Details Reason Approved By
01/01/2022 1.0 Initial Issue New SOP QA Head
14/04/2025 2.0 Annexure additions and tagging protocol Compliance Enhancement QA Head
API Manufacturing V 2.0 Tags:API batch record, API BMR, API calibration, API centrifuge, API cleaning, API crystallization, API deviation, API documentation, API drying, API equipment cleaning, API filtration, API GMP compliance, API granulation, API hold time, API impurities, API line clearance, API manufacturing, API process, API quality control, API reactor, API sampling, API solvent handling, API validation, API waste disposal, API yield

Post navigation

Previous Post: Analytical Method Development: SOP for In-Vitro Release Testing for Topical Products – V 2.0
Next Post: Creams: SOP for Product Recall Procedures for Creams – V 2.0

Standard Operating Procedures V 1.0

  • Aerosols
  • Analytical Method Development
  • Bioequivalence Bioavailability Study
  • Capsule Formulation
  • Clinical Studies
  • Creams
  • Data Integrity
  • Dental Dosage Forms
  • Drug Discovery
  • Environment, Health and Safety
  • Formulation Development
  • Gels
  • Good Distribution Practice
  • Good Warehousing Practices
  • In-Process Control
  • Injectables
  • Liquid Orals
  • Liposome and Emulsion Formulations
  • Lotions
  • Lyophilized Products
  • Maintenance Dept.
  • Medical Devices
  • Metered-Dose Inhaler
  • Microbiology Testing
  • Nanoparticle Formulation
  • Nasal Spray Formulations
  • Nebulizers
  • Ocular (Eye) Dosage Forms
  • Ointments
  • Otic (Ear) Dosage Forms
  • Pharmacovigilance
  • Powder & Granules
  • Purchase Departments
  • Quality Assurance
  • Quality Control
  • Raw Material Stores
  • Regulatory Affairs
  • Tablet Manufacturing
  • Rectal Dosage Forms
  • Transdermal Patches
  • Vaginal Dosage Forms
  • Validations and Qualifications

Read SOPs in your Language:

 - 
Bengali
 - 
bn
English
 - 
en
Gujarati
 - 
gu
Hindi
 - 
hi
Malayalam
 - 
ml
Marathi
 - 
mr
Punjabi
 - 
pa
Tamil
 - 
ta
Telugu
 - 
te

NEW! Revised SOPs – V 2.0

  • Aerosols V 2.0
  • Analytical Method Development V 2.0
  • API Manufacturing V 2.0
  • BA-BE Studies V 2.0
  • Biosimilars V 2.0
  • Capsules V 2.0
  • Creams V 2.0
  • Elixers V 2.0
  • Gels V 2.0
  • Injectables V 2.0
  • Ointments V 2.0
  • Raw Material Warehouse V 2.0
  • Tablet Manufacturing V2.0

New Publication: A must for All.

Copyright © 2025 SOP Guide for Pharma.

Powered by PressBook WordPress theme

Go to mobile version