Empty capsule shells – SOP Guide for Pharma https://www.pharmasop.in The Ultimate Resource for Pharmaceutical SOPs and Best Practices Tue, 01 Apr 2025 14:16:00 +0000 en-US hourly 1 https://wordpress.org/?v=6.7.2 Capsule: SOP for Addressing Equipment Malfunctions During Encapsulation – V 2.0 https://www.pharmasop.in/capsule-sop-for-addressing-equipment-malfunctions-during-encapsulation-v-2-0/ Tue, 01 Apr 2025 14:16:00 +0000 https://www.pharmasop.in/?p=9482 Read More “Capsule: SOP for Addressing Equipment Malfunctions During Encapsulation – V 2.0” »

]]>
Capsule: SOP for Addressing Equipment Malfunctions During Encapsulation – V 2.0

Standard Operating Procedure for Addressing Equipment Malfunctions During Encapsulation

Department Capsule Manufacturing
SOP No. SOP/CM/108/2025
Supersedes SOP/CM/108/2022
Page No. Page 1 of 6
Issue Date 01/02/2025
Effective Date 05/02/2025
Review Date 01/02/2026

1. Purpose

The purpose of this SOP is to establish the procedure for addressing equipment malfunctions during the encapsulation process. Identifying and rectifying malfunctions promptly is essential to maintaining production efficiency, product quality, and compliance with Good Manufacturing Practices (GMP).

2. Scope

This SOP applies to all capsule manufacturing equipment, including capsule filling machines, encapsulation systems, and related equipment. It covers the procedures for identifying, troubleshooting, and rectifying malfunctions during the encapsulation process.

3. Responsibilities

  • Production Operators: Responsible for identifying malfunctions during encapsulation, reporting issues promptly, and following the corrective actions outlined in this SOP.
  • Maintenance Team: Responsible for performing repairs or adjustments to malfunctioning equipment and ensuring that it meets operational specifications before resuming production.
  • Quality Control (QC) Team: Responsible for verifying that the encapsulation process resumes after repairs and meets product quality specifications.
  • Production Supervisor: Responsible for overseeing the equipment troubleshooting and repair process, ensuring that all procedures are followed, and coordinating between production, maintenance, and QC teams.

4. Accountability

The Capsule Manufacturing Supervisor is accountable for ensuring that all equipment malfunctions are addressed promptly, and production is not delayed. The Maintenance Manager is accountable for ensuring that equipment repairs are performed effectively, while the QA Manager is responsible for ensuring that product quality standards are met post-repair.

5. Procedure

5.1 Identifying Equipment Malfunctions

The first step in addressing equipment malfunctions is to identify issues as early as possible:

  1. Monitor Equipment Performance

    1. Regularly monitor the performance of capsule filling machines and other related equipment during production. Check for abnormalities such as irregular fill volumes, capsule leakage, or incomplete sealing.
    2. Ensure that operators are trained to recognize equipment malfunctions, such as strange noises, abnormal vibration, or error messages on the control panels.
  2. Report Malfunctions

    1. If an issue is detected, the production operator should immediately report the malfunction to the Production Supervisor and the Maintenance Team.
    2. Record the issue in the Equipment Malfunction Log (Annexure-1) with details of the malfunction, time of occurrence, and any relevant observations.

5.2 Troubleshooting Equipment Issues

Once a malfunction is reported, follow the troubleshooting process to identify the root cause:

  1. Consult Equipment Manuals

    1. Refer to the equipment manuals and troubleshooting guides for specific machines involved in the malfunction. Follow the manufacturer’s recommendations for addressing the issue.
  2. Perform Diagnostics

    1. The Maintenance Team should run diagnostic tests, if available, to detect any electrical or mechanical issues with the equipment.
    2. If the malfunction involves a mechanical failure, check for issues such as blockages, wear and tear, or component misalignment.
  3. Identify and Correct the Problem

    1. After diagnosing the malfunction, perform the necessary repairs or adjustments. Common fixes may involve recalibration, replacing faulty components, or cleaning the equipment to remove blockages.
    2. Ensure that any damaged components are replaced with certified spare parts to maintain equipment performance and ensure GMP compliance.

5.3 Testing and Verifying Equipment after Repairs

Once repairs are made, conduct tests to ensure that the equipment is functioning properly:

  1. Test the Equipment

    1. After making repairs, conduct a series of tests to verify that the machine is operating correctly. This may involve running a few test batches to check capsule fill volumes, sealing, and weight consistency.
    2. Ensure that all functions of the equipment are restored to their original specifications, such as filling speed, capsule alignment, and sealing integrity.
  2. Document Test Results

    1. Record the test results in the Equipment Verification Log (Annexure-2) to confirm that the equipment has passed all tests and is ready to resume production.
    2. Ensure that the test results are reviewed and approved by the Production Supervisor and the QA team.

5.4 Resuming Production

Once the malfunction is resolved and the equipment is verified to be functioning properly, proceed with resuming production:

  1. Resume Production

    1. Once the equipment passes all tests, production can resume. Ensure that production operators are informed that the issue has been resolved and that they are ready to continue the process.
  2. Monitor the Equipment

    1. Monitor the equipment closely during the initial production runs after the malfunction is addressed. Pay attention to any signs that the problem might recur.

5.5 Documentation and Reporting

Proper documentation of the malfunction, corrective actions, and testing is essential for traceability and regulatory compliance:

  1. Document the Malfunction

    1. Complete the Equipment Malfunction Log (Annexure-1) with all relevant details about the malfunction, the root cause, and the actions taken to correct the issue.
  2. Complete the Equipment Verification Log

    1. After completing the repairs and tests, ensure that the Equipment Verification Log (Annexure-2) is updated to reflect that the equipment is back to its operational state.

6. Abbreviations

  • SOP: Standard Operating Procedure
  • GMP: Good Manufacturing Practice
  • QC: Quality Control
  • QA: Quality Assurance
  • PM: Preventive Maintenance
  • RM: Raw Material

7. Documents

  1. Equipment Malfunction Log (Annexure-1)
  2. Equipment Verification Log (Annexure-2)
  3. Deviation Log (Annexure-3)
  4. Maintenance Log (Annexure-4)

8. References

  • USP <1163> – Pharmaceutical Dosage Forms: Capsules
  • FDA Guidelines for Capsule Manufacturing
  • Good Manufacturing Practice (GMP) Guidelines

9. SOP Version

Version: 2
You said:
​continue
ChatGPT said:
Certainly! Continuing from SOP 108: SOP for Addressing Equipment Malfunctions During Encapsulation, here is the remainder:

html
Copy

9. SOP Version

Version: 2.0

10. Approval Section

Prepared By Checked By Approved By
Signature
Date
Name
Designation
Department

11. Annexures

Annexure-1: Equipment Malfunction Log

Malfunction ID Batch ID Description Root Cause Corrective Action Operator Approval Status
MF-001 Batch 001 Capsule filling machine stopped unexpectedly Electrical short-circuit in motor Replaced motor and reset machine settings John Doe Approved

Annexure-2: Equipment Verification Log

Test ID Test Description Test Result Operator Verification Date
TEST-001 Filling accuracy test Pass Jane Smith 02/02/2025

Annexure-3: Deviation Log

Deviation ID Batch ID Description Corrective Action Operator Approval Status
DEV-001 Batch 001 Irregular capsule weight Recalibrated the capsule filling machine John Doe Approved

Annexure-4: Maintenance Log

Equipment ID Maintenance Date Maintenance Activity Performed By Next Maintenance Due
Filling Machine 001 02/02/2025 Replaced motor and calibrated sensors Jane Smith 02/02/2026

Revision History:

Revision Date Revision No. Revision Details Reason for Revision Approved By
01/01/2024 1.0 Initial Version New SOP Creation QA Head
01/02/2025 2.0 Updated troubleshooting and corrective action procedures Clarified equipment malfunction handling QA Head
]]>
Capsule: SOP for Monitoring Capsule-Fill Density in Production – V 2.0 https://www.pharmasop.in/capsule-sop-for-monitoring-capsule-fill-density-in-production-v-2-0/ Tue, 01 Apr 2025 07:26:00 +0000 https://www.pharmasop.in/?p=9481 Read More “Capsule: SOP for Monitoring Capsule-Fill Density in Production – V 2.0” »

]]>
Capsule: SOP for Monitoring Capsule-Fill Density in Production – V 2.0

Standard Operating Procedure for Monitoring Capsule-Fill Density in Production

Department Capsule Manufacturing
SOP No. SOP/CM/107/2025
Supersedes SOP/CM/107/2022
Page No. Page 1 of 6
Issue Date 01/02/2025
Effective Date 05/02/2025
Review Date 01/02/2026

1. Purpose

The purpose of this SOP is to establish the procedure for monitoring the fill density of capsules during the manufacturing process. Ensuring proper fill density is critical for maintaining product consistency, ensuring accurate dosing, and meeting regulatory standards.

2. Scope

This SOP applies to all processes involved in capsule filling, including the preparation of the fill material, monitoring during encapsulation, and verification of fill density for both hard gelatin and soft gelatin capsules.

3. Responsibilities

  • Production Operators: Responsible for performing the fill density checks as outlined in this SOP and ensuring the correct fill density is maintained during capsule production.
  • Quality Control (QC) Team: Responsible for conducting routine checks of capsule fill density, recording data, and performing corrective actions in case of deviations.
  • Quality Assurance (QA) Team: Ensures compliance with the SOP and regulatory requirements. Reviews documentation and test results to verify fill density compliance.
  • Production Supervisor: Oversees the capsule filling process, ensures that operators follow the SOP, and ensures that any issues are addressed promptly.

4. Accountability

The Capsule Manufacturing Supervisor is accountable for ensuring that fill density is monitored as per the SOP, and corrective actions are taken if necessary. The QA Manager is responsible for overseeing the overall compliance and ensuring the final product meets the required specifications.

5. Procedure

5.1 Monitoring Capsule-Fill Density

Monitor the fill density during capsule production to ensure that each capsule meets the specified requirements for content uniformity:

  1. Prepare for Density Monitoring

    1. Ensure that the capsule filling machine is calibrated and functioning properly before starting production.
    2. Verify that the fill material is adequately mixed and that the granules or powder are uniform in size and consistency.
  2. Select Sampling Method

    1. Randomly select a set number of capsules at different stages of the production run (e.g., every 30 minutes or after every 500 capsules). The selected samples should be representative of the entire batch.
    2. Document the time of sampling and batch number in the Sampling Log (Annexure-1).
  3. Measure Capsule-Fill Density

    1. Weigh each capsule individually and record the data. Ensure the use of an analytical balance calibrated according to the prescribed standards.
    2. Calculate the fill density by dividing the weight of the capsule by the known volume of the capsule shell. Compare the result to the specification limits for the fill density.
    3. If using liquid-filled capsules, ensure that the liquid is evenly distributed and that there are no air bubbles present in the capsule before weighing.
  4. Document Results

    1. Record the fill density for each capsule sampled, including the time, weight, and calculated density, in the Fill Density Log (Annexure-2).
    2. Ensure that all data entries are signed off by the responsible operator and reviewed by QC personnel.

5.2 Handling Deviations

If the capsule fill density does not meet the specified range, take the following corrective actions:

  1. Investigate the Cause of Deviation

    1. Identify any factors that could have contributed to the deviation, such as equipment malfunction, variation in raw materials, or incorrect fill material preparation.
    2. Check the capsule filling machine for proper calibration, and ensure that there is no material build-up in the feeding system.
  2. Correct the Process

    1. Adjust the machine settings, refill material preparation, or capsule handling as needed to correct the fill density deviation.
    2. If the issue cannot be resolved immediately, halt the production process and investigate further.
  3. Re-sample and Re-test

    1. After adjustments are made, conduct a new set of random tests to ensure that the fill density is back within acceptable limits.
    2. Document all findings, including the cause of deviation and the actions taken, in the Deviation Log (Annexure-3).

5.3 Frequency of Monitoring

The frequency of monitoring depends on the production volume and batch size. It is recommended to monitor fill density at regular intervals:

  1. For small batches, conduct fill density monitoring at least once every 100 capsules.
  2. For large batches, conduct monitoring at least once every 500 capsules or every 30 minutes of production.
  3. Increase the frequency of checks if any inconsistencies are detected or if adjustments are made to the filling process.

5.4 Final Approval and Release

Once the monitoring process is completed and the fill density is verified to meet specifications, proceed with the following steps:

  1. QA Review

    1. The QA team reviews all fill density records, including any deviations and corrective actions taken.
    2. Ensure that all data is complete and accurate, and that the batch complies with the fill density specifications.
  2. Approval for Release

    1. If the capsule fill density is within the required range, approve the batch for continued production or packaging.

6. Abbreviations

  • SOP: Standard Operating Procedure
  • GMP: Good Manufacturing Practice
  • QC: Quality Control
  • QA: Quality Assurance

7. Documents

  1. Fill Density Log (Annexure-2)
  2. Sampling Log (Annexure-1)
  3. Deviation Log (Annexure-3)
  4. Batch Records (Annexure-4)

8. References

  • USP <1163> – Pharmaceutical Dosage Forms: Capsules
  • FDA Guidelines for Capsule Manufacturing
  • Good Manufacturing Practice (GMP) Guidelines

9. SOP Version

Version: 2.0

10. Approval Section

Prepared By Checked By Approved By
Signature
Date
Name
Designation
Department

11. Annexures

Annexure-1: Sampling Log

Sample ID Sampling Time Operator Batch ID
Sample 001 10:00 AM John Doe Batch 001

Annexure-2: Fill Density Log

Sample ID Weight (mg) Fill Density (g/cm³) Pass/Fail Operator
Sample 001 500 0.75 Pass Jane Smith

Annexure-3: Deviation Log

Deviation ID Batch ID Description Corrective Action
You said:
​continue
ChatGPT said:
Certainly! Continuing from Annexure-3: Deviation Log:

html
Copy

Corrective Action Operator Approval Status
DEV-001 Batch 001 Fill density outside acceptable range Re-calibrated machine and adjusted material flow John Doe Approved

Annexure-4: Batch Records

Batch ID Gelatin Composition Fill Material Operator Adjustments Made Approval Status
Batch 001 Standard Powdered Fill Jane Smith Adjusted for temperature variation in production environment Approved

Revision History:

Revision Date Revision No. Revision Details Reason for Revision Approved By
01/01/2024 1.0 Initial version New SOP Creation QA Head
01/02/2025 2.0 Updated monitoring frequency and adjustments Improved accuracy and compliance QA Head
]]>
Capsule: SOP for Adjusting Gelatin Composition for Seasonal Variations – V 2.0 https://www.pharmasop.in/capsule-sop-for-adjusting-gelatin-composition-for-seasonal-variations-v-2-0-2/ Tue, 01 Apr 2025 00:36:00 +0000 https://www.pharmasop.in/?p=9480 Read More “Capsule: SOP for Adjusting Gelatin Composition for Seasonal Variations – V 2.0” »

]]>
Capsule: SOP for Adjusting Gelatin Composition for Seasonal Variations – V 2.0

Standard Operating Procedure for Adjusting Gelatin Composition for Seasonal Variations

Department Capsule Manufacturing
SOP No. SOP/CM/106/2025
Supersedes SOP/CM/106/2022
Page No. Page 1 of 6
Issue Date 01/02/2025
Effective Date 05/02/2025
Review Date 01/02/2026

1. Purpose

The purpose of this SOP is to outline the procedure for adjusting gelatin composition in capsule manufacturing to account for seasonal variations in environmental conditions. Changes in temperature, humidity, and other factors during different seasons can affect the properties of gelatin, necessitating adjustments to maintain product quality.

2. Scope

This SOP applies to all gelatin-based capsule manufacturing processes where the composition may need to be adjusted based on seasonal variations. It includes adjustments to gelatin concentration, additives, and processing conditions.

3. Responsibilities

  • Production Operators: Responsible for implementing the adjustments to the gelatin composition according to the SOP and ensuring consistent quality during production.
  • Quality Control (QC) Team: Responsible for monitoring the properties of the gelatin and conducting tests to verify the suitability of the adjusted composition.
  • Quality Assurance (QA) Team: Ensures that all adjustments are documented and that the production process complies with regulatory standards. Reviews and approves the adjusted gelatin composition.
  • Production Supervisor: Oversees the entire process, ensures that adjustments are made correctly, and coordinates between production, QC, and QA teams.

4. Accountability

The Capsule Manufacturing Supervisor is accountable for ensuring that adjustments to the gelatin composition are made in compliance with this SOP. The QA Manager is responsible for verifying the adjustments and reviewing the final product for compliance with quality standards.

5. Procedure

5.1 Identifying Seasonal Variations

To determine the need for adjusting gelatin composition, monitor the environmental conditions and identify any seasonal variations that may affect the manufacturing process:

  1. Monitor Temperature and Humidity

    1. Track temperature and humidity levels in the production area to identify seasonal fluctuations. Ensure that the production environment is within the ideal range for gelatin processing.
    2. Document these environmental conditions regularly in the Environmental Monitoring Log (Annexure-1).
  2. Evaluate Gelatin Properties

    1. Regularly assess the properties of the gelatin, including its viscosity, moisture content, and solubility, to determine if seasonal variations are affecting the material.
    2. Record observations in the Gelatin Properties Log (Annexure-2) to track trends over time.

5.2 Adjusting Gelatin Composition

Once seasonal variations have been identified, adjust the gelatin composition accordingly to maintain product quality:

  1. Adjust Gelatin Concentration

    1. Increase or decrease the gelatin concentration as needed based on temperature and humidity. Higher humidity may require reducing the gelatin concentration to maintain consistency, while lower humidity may require an increase.
    2. Consult with the R&D or formulation team to determine the ideal concentration for the current environmental conditions.
  2. Modify Additives

    1. Adjust the quantity of plasticizers, stabilizers, or other additives to compensate for changes in gelatin properties caused by seasonal changes.
    2. Ensure that the adjusted additives do not affect the final capsule’s quality or stability.
  3. Monitor Gelatin Melting Point

    1. Check the melting point of the gelatin regularly during seasonal transitions, as changes in temperature may affect the gelatin’s behavior during encapsulation.
    2. Adjust the encapsulation temperature if necessary to ensure proper sealing of the capsules.

5.3 Conducting Quality Control Tests

After adjusting the gelatin composition, conduct the necessary quality control tests to verify that the adjustments have not negatively impacted the quality of the capsules:

  1. Gelatin Testing

    1. Perform tests on the gelatin to ensure that it meets the required viscosity, solubility, and gel strength. This ensures that the gelatin will perform properly during capsule filling and sealing.
    2. Document test results in the Gelatin Quality Control Log (Annexure-3).
  2. Capsule Testing

    1. Conduct tests on filled capsules to ensure that they meet the necessary specifications for weight, size, fill volume, and sealing integrity.
    2. If the capsules do not meet specifications, revisit the adjustments to the gelatin composition and make further refinements.

5.4 Monitoring Production

Monitor the production process to ensure that the adjusted gelatin composition is functioning as intended:

  1. Observe Gelatin Flow

    1. Monitor the flow of the gelatin during capsule filling to ensure smooth processing without clogging or irregular filling.
    2. Document any irregularities in the Gelatin Flow Log (Annexure-4) and adjust the composition as needed to maintain optimal flow.
  2. Monitor Capsule Sealing

    1. Check the capsule sealing process to ensure that the adjusted gelatin composition provides a strong and consistent seal. This is especially important during colder weather when gelatin may become more brittle.

5.5 Final Approval and Release

Once the gelatin composition adjustments have been made and the production process is running smoothly, proceed with the following steps:

  1. QA Review

    1. The QA team should review all records, including quality control tests, batch records, and adjustments made to the gelatin composition, to ensure compliance with the required standards.
  2. Approval for Production

    1. If the adjusted gelatin composition is verified to meet the required specifications, approve the batch for continued production and packaging.

6. Abbreviations

  • SOP: Standard Operating Procedure
  • GMP: Good Manufacturing Practice
  • QC: Quality Control
  • QA: Quality Assurance

7. Documents

  1. Gelatin Properties Log (Annexure-2)
  2. Gelatin Quality Control Log (Annexure-3)
  3. Gelatin Flow Log (Annexure-4)
  4. Batch Records (Annexure-5)

8. References

  • USP <1163> – Pharmaceutical Dosage Forms: Capsules
  • FDA Guidelines for Capsule Manufacturing
  • Good Manufacturing Practice (GMP) Guidelines

9. SOP Version

Version: 2.0

10. Approval Section

Prepared By Checked By Approved By
Signature
Date
Name
Designation
Department

11. Annexures

Annexure-1: Environmental Monitoring Log

Date Temperature (°C) Humidity (%) Operator
01/02/2025 22°C 55% John Doe

Annexure-2: Gelatin Properties Log

Date Viscosity (cP) Moisture Content (%) Solubility (%) Operator
01/02/2025 300 13% 98% Jane Smith

Revision History:

Revision Date Revision No. Revision Details Reason for Revision Approved By
01/01/2024 1.0 Initial Version New SOP Creation QA Head
01/02/2025 2.0 Updated gelatin adjustment procedures Seasonal Variation Adaptation QA Head
]]>
Capsule: SOP for Adjusting Gelatin Composition for Seasonal Variations – V 2.0 https://www.pharmasop.in/capsule-sop-for-adjusting-gelatin-composition-for-seasonal-variations-v-2-0/ Mon, 31 Mar 2025 17:46:00 +0000 https://www.pharmasop.in/?p=9479 Read More “Capsule: SOP for Adjusting Gelatin Composition for Seasonal Variations – V 2.0” »

]]>
Capsule: SOP for Adjusting Gelatin Composition for Seasonal Variations – V 2.0

Standard Operating Procedure for Adjusting Gelatin Composition for Seasonal Variations

Department Capsule Manufacturing
SOP No. SOP/CM/106/2025
Supersedes SOP/CM/106/2022
Page No. Page 1 of 6
Issue Date 01/02/2025
Effective Date 05/02/2025
Review Date 01/02/2026

1. Purpose

The purpose of this SOP is to outline the procedure for adjusting gelatin composition in capsule manufacturing to account for seasonal variations in environmental conditions. Changes in temperature, humidity, and other factors during different seasons can affect the properties of gelatin, necessitating adjustments to maintain product quality.

2. Scope

This SOP applies to all gelatin-based capsule manufacturing processes where the composition may need to be adjusted based on seasonal variations. It includes adjustments to gelatin concentration, additives, and processing conditions.

3. Responsibilities

  • Production Operators: Responsible for implementing the adjustments to the gelatin composition according to the SOP and ensuring consistent quality during production.
  • Quality Control (QC) Team: Responsible for monitoring the properties of the gelatin and conducting tests to verify the suitability of the adjusted composition.
  • Quality Assurance (QA) Team: Ensures that all adjustments are documented and that the production process complies with regulatory standards. Reviews and approves the adjusted gelatin composition.
  • Production Supervisor: Oversees the entire process, ensures that adjustments are made correctly, and coordinates between production, QC, and QA teams.

4. Accountability

The Capsule Manufacturing Supervisor is accountable for ensuring that adjustments to the gelatin composition are made in compliance with this SOP. The QA Manager is responsible for verifying the adjustments and reviewing the final product for compliance with quality standards.

5. Procedure

5.1 Identifying Seasonal Variations

To determine the need for adjusting gelatin composition, monitor the environmental conditions and identify any seasonal variations that may affect the manufacturing process:

  1. Monitor Temperature and Humidity

    1. Track temperature and humidity levels in the production area to identify seasonal fluctuations. Ensure that the production environment is within the ideal range for gelatin processing.
    2. Document these environmental conditions regularly in the Environmental Monitoring Log (Annexure-1).
  2. Evaluate Gelatin Properties

    1. Regularly assess the properties of the gelatin, including its viscosity, moisture content, and solubility, to determine if seasonal variations are affecting the material.
    2. Record observations in the Gelatin Properties Log (Annexure-2) to track trends over time.

5.2 Adjusting Gelatin Composition

Once seasonal variations have been identified, adjust the gelatin composition accordingly to maintain product quality:

  1. Adjust Gelatin Concentration

    1. Increase or decrease the gelatin concentration as needed based on temperature and humidity. Higher humidity may require reducing the gelatin concentration to maintain consistency, while lower humidity may require an increase.
    2. Consult with the R&D or formulation team to determine the ideal concentration for the current environmental conditions.
  2. Modify Additives

    1. Adjust the quantity of plasticizers, stabilizers, or other additives to compensate for changes in gelatin properties caused by seasonal changes.
    2. Ensure that the adjusted additives do not affect the final capsule’s quality or stability.
  3. Monitor Gelatin Melting Point

    1. Check the melting point of the gelatin regularly during seasonal transitions, as changes in temperature may affect the gelatin’s behavior during encapsulation.
    2. Adjust the encapsulation temperature if necessary to ensure proper sealing of the capsules.

5.3 Conducting Quality Control Tests

After adjusting the gelatin composition, conduct the necessary quality control tests to verify that the adjustments have not negatively impacted the quality of the capsules:

  1. Gelatin Testing

    1. Perform tests on the gelatin to ensure that it meets the required viscosity, solubility, and gel strength. This ensures that the gelatin will perform properly during capsule filling and sealing.
    2. Document test results in the Gelatin Quality Control Log (Annexure-3).
  2. Capsule Testing

    1. Conduct tests on filled capsules to ensure that they meet the necessary specifications for weight, size, fill volume, and sealing integrity.
    2. If the capsules do not meet specifications, revisit the adjustments to the gelatin composition and make further refinements.

5.4 Monitoring Production

Monitor the production process to ensure that the adjusted gelatin composition is functioning as intended:

  1. Observe Gelatin Flow

    1. Monitor the flow of the gelatin during capsule filling to ensure smooth processing without clogging or irregular filling.
    2. Document any irregularities in the Gelatin Flow Log (Annexure-4) and adjust the composition as needed to maintain optimal flow.
  2. Monitor Capsule Sealing

    1. Check the capsule sealing process to ensure that the adjusted gelatin composition provides a strong and consistent seal. This is especially important during colder weather when gelatin may become more brittle.

5.5 Final Approval and Release

Once the gelatin composition adjustments have been made and the production process is running smoothly, proceed with the following steps:

  1. QA Review

    1. The QA team should review all records, including quality control tests, batch records, and adjustments made to the gelatin composition, to ensure compliance with the required standards.
  2. Approval for Production

    1. If the adjusted gelatin composition is verified to meet the required specifications, approve the batch for continued production and packaging.

6. Abbreviations

  • SOP: Standard Operating Procedure
  • GMP: Good Manufacturing Practice
  • QC: Quality Control
  • QA: Quality Assurance

7. Documents

  1. Gelatin Properties Log (Annexure-2)
  2. Gelatin Quality Control Log (Annexure-3)
  3. Gelatin Flow Log (Annexure-4)
  4. Batch Records (Annexure-5)

8. References

  • USP <1163> – Pharmaceutical Dosage Forms: Capsules
  • FDA Guidelines for Capsule Manufacturing
  • Good Manufacturing Practice (GMP) Guidelines

9. SOP Version

Version: 2.0

10. Approval Section

Prepared By Checked By Approved By
Signature
Date
Name
Designation
Department

11. Annexures

Annexure-1: Environmental Monitoring Log

Date Temperature (°C) Humidity (%) Operator
01/02/2025 22°C 55% John Doe

Annexure-2: Gelatin Properties Log

Date Viscosity (cP) Moisture Content (%) Solubility (%) Operator
01/02/2025 300 13% 98% Jane Smith

Revision History:

Revision Date Revision No. Revision Details Reason for Revision Approved By
01/01/2024 1.0 Initial Version New SOP Creation QA Head
01/02/2025 2.0 Updated gelatin adjustment procedures Seasonal Variation Adaptation QA Head
]]>
Capsule: SOP for Ensuring Compliance with GMP in Capsule Production – V 2.0 https://www.pharmasop.in/capsule-sop-for-ensuring-compliance-with-gmp-in-capsule-production-v-2-0/ Mon, 31 Mar 2025 10:56:00 +0000 https://www.pharmasop.in/?p=9478 Read More “Capsule: SOP for Ensuring Compliance with GMP in Capsule Production – V 2.0” »

]]>
Capsule: SOP for Ensuring Compliance with GMP in Capsule Production – V 2.0

Standard Operating Procedure for Ensuring Compliance with GMP in Capsule Production

Department Capsule Manufacturing
SOP No. SOP/CM/105/2025
Supersedes SOP/CM/105/2022
Page No. Page 1 of 6
Issue Date 01/02/2025
Effective Date 05/02/2025
Review Date 01/02/2026

1. Purpose

The purpose of this SOP is to establish the procedure for ensuring compliance with Good Manufacturing Practices (GMP) during capsule production. This procedure is designed to maintain the highest quality standards and ensure that all aspects of capsule manufacturing meet regulatory requirements.

2. Scope

This SOP applies to all aspects of capsule production, including raw material handling, formulation, encapsulation, drying, quality control testing, and packaging. It outlines the responsibilities and procedures to ensure that capsule production processes comply with GMP guidelines at all stages.

3. Responsibilities

  • Production Operators: Responsible for following the procedures outlined in this SOP, ensuring that capsule production processes are in compliance with GMP standards.
  • Quality Control (QC) Team: Responsible for overseeing the testing and monitoring of production processes to ensure compliance with GMP. QC will also document and report any deviations from GMP.
  • Quality Assurance (QA) Team: Ensures that the entire production process adheres to GMP standards and reviews all documentation to confirm compliance with regulatory requirements.
  • Production Supervisor: Responsible for supervising the production process and ensuring that all operators follow GMP guidelines. The supervisor must also manage corrective actions in case of deviations from GMP.

4. Accountability

The Capsule Manufacturing Supervisor is accountable for ensuring compliance with GMP during the production process. The QA Manager is responsible for reviewing and approving all GMP compliance-related documentation and actions.

5. Procedure

5.1 GMP Training and Education

Ensure that all personnel involved in capsule production are properly trained and educated on GMP guidelines:

  1. Provide Initial GMP Training

    1. All new employees involved in capsule production must undergo an initial GMP training session before beginning work.
    2. The training should cover GMP regulations, quality control procedures, and the importance of maintaining compliance in capsule production.
  2. Conduct Regular Refresher Training

    1. Conduct periodic refresher training for all production staff to ensure that they stay updated with any changes in GMP regulations or internal processes.
    2. Keep records of all training sessions, including the names of attendees, training dates, and topics covered, in the Training Log (Annexure-1).

5.2 Document Control and Record Keeping

Ensure that all manufacturing records are accurate, complete, and maintained according to GMP guidelines:

  1. Maintain Accurate Batch Records

    1. Ensure that all batch records are completed accurately, including the recording of raw material batches, production processes, equipment used, and test results.
    2. Batch records should be signed off by authorized personnel and reviewed by QA for completeness and accuracy.
  2. Document Handling

    1. Ensure that all GMP-related documents (e.g., batch records, SOPs, test results) are properly stored and controlled to prevent unauthorized access or changes.
    2. Use a document control system to track the revision history and approval of all GMP-related documents.

5.3 Equipment Calibration and Maintenance

Ensure that all equipment used in capsule production is properly calibrated, maintained, and functioning:

  1. Regular Calibration of Equipment

    1. All equipment used in capsule manufacturing, such as filling machines, drying ovens, and QC testing equipment, must be calibrated according to the manufacturer’s specifications.
    2. Calibration records should be maintained in the Equipment Calibration Log (Annexure-2), including calibration dates, results, and any corrective actions taken.
  2. Preventive Maintenance

    1. Establish a preventive maintenance schedule for all equipment used in capsule production. This schedule should include routine inspections, cleaning, and part replacements to ensure optimal performance.
    2. Record all maintenance activities in the Maintenance Log (Annexure-3) to ensure traceability and compliance with GMP guidelines.

5.4 Production and Process Controls

Ensure that all production processes are controlled and monitored to maintain compliance with GMP:

  1. Monitor Critical Process Parameters

    1. Monitor critical parameters during capsule manufacturing, such as temperature, humidity, capsule weight, and fill volume, to ensure that they remain within acceptable limits.
    2. Use automated systems to continuously monitor these parameters, and record the data in the Production Monitoring Log (Annexure-4).
  2. Investigate Deviations

    1. If any process deviation is detected, immediately investigate the cause of the deviation, and implement corrective actions to return the process to compliance.
    2. Document all deviations and corrective actions in the Deviation Log (Annexure-5), and review them to prevent recurrence.

5.5 Compliance Audits and Inspections

Regularly conduct audits and inspections to verify compliance with GMP and regulatory requirements:

  1. Conduct Internal Audits

    1. Conduct regular internal GMP audits to assess compliance with SOPs, equipment calibration, documentation, and overall manufacturing processes.
    2. Audit findings should be documented, and corrective actions should be implemented as necessary.
  2. Prepare for External Audits

    1. Prepare for external GMP inspections by regulatory bodies (e.g., FDA, EMA) by ensuring that all documents, records, and procedures are up-to-date and in compliance with regulatory requirements.
    2. Address any observations made during external audits and implement corrective actions to maintain compliance.

5.6 Final Approval and Release

Once all GMP procedures have been followed and documented, the following steps should be taken:

  1. QA Review

    1. The QA team reviews all GMP-related records, including batch records, equipment maintenance logs, and deviation reports, to ensure that the production process complies with GMP standards.
  2. Approval for Release

    1. If the batch complies with GMP and all documentation is complete, the batch is approved for release and packaging.

6. Abbreviations

  • SOP: Standard Operating Procedure
  • GMP: Good Manufacturing Practice
  • QC: Quality Control
  • QA: Quality Assurance
  • BPR: Batch Production Record

7. Documents

  1. Training Log (Annexure-1)
  2. Equipment Calibration Log (Annexure-2)
  3. Maintenance Log (Annexure-3)
  4. Production Monitoring Log (Annexure-4)
  5. Deviation Log (Annexure-5)

8. References

  • USP <1163> – Pharmaceutical Dosage Forms: Capsules
  • FDA Guidelines for Capsule Manufacturing
  • Good Manufacturing Practice (GMP) Guidelines

9. SOP Version

Version: 2.0

10. Approval Section

Prepared By Checked By Approved By
Signature
Date
Name
Designation
Department

11. Annexures

Annexure-1: Training Log

Employee Name Training Date Training Topic Trainer Sign-off
John Doe 02/01/2025 GMP Training Jane Smith ✔

Annexure-2: Equipment Calibration Log

Equipment ID Calibration Date Calibration Result Next Calibration Date Operator
Filling Machine 001 01/02/2025 Pass 01/02/2026 John Doe

Annexure-3: Maintenance Log

Equipment ID Maintenance Date Maintenance Activity Performed By Next Maintenance Due
Sealing Machine 001 02/02/2025 Replaced sealing part Jane Smith 02/02/2026

Annexure-4: Production Monitoring Log

Batch ID Monitoring Date Parameter Monitored Result Action Taken
Batch 001 01/02/2025 Capsule Weight 500 mg None

Annexure-5: Deviation Log

Deviation ID Batch ID Deviation Description Corrective Action Taken Operator Approval Status
DEV-001 Batch 001 Capsule weight outside acceptable range Recalibrated machine John Doe Approved

Revision History:

Revision Date Revision No. Revision Details Reason for Revision Approved By
01/01/2024 1.0 Initial Version New SOP Creation QA Head
01/02/2025 2.0 Updated compliance monitoring procedures Standardization QA Head
]]>
Capsule: SOP for Conducting Randomized Sampling of Capsules – V 2.0 https://www.pharmasop.in/capsule-sop-for-conducting-randomized-sampling-of-capsules-v-2-0/ Mon, 31 Mar 2025 04:06:00 +0000 https://www.pharmasop.in/?p=9477 Read More “Capsule: SOP for Conducting Randomized Sampling of Capsules – V 2.0” »

]]>
Capsule: SOP for Conducting Randomized Sampling of Capsules – V 2.0

Standard Operating Procedure for Conducting Randomized Sampling of Capsules

Department Capsule Manufacturing
SOP No. SOP/CM/104/2025
Supersedes SOP/CM/104/2022
Page No. Page 1 of 6
Issue Date 01/02/2025
Effective Date 05/02/2025
Review Date 01/02/2026

1. Purpose

The purpose of this SOP is to establish a standardized procedure for conducting randomized sampling of capsules. Randomized sampling ensures that the samples collected are representative of the entire batch, allowing for accurate quality control testing and ensuring the final product meets all quality specifications.

2. Scope

This SOP applies to the process of random sampling during the capsule manufacturing process. It covers the selection, collection, and handling of samples from the production batch for quality control testing.

3. Responsibilities

  • Production Operators: Responsible for following the sampling procedure to collect samples from the production batch and ensuring proper labeling.
  • Quality Control (QC) Team: Responsible for overseeing the randomized sampling process, ensuring the proper collection of samples, and conducting the necessary tests on the samples.
  • Quality Assurance (QA) Team: Ensures that the sampling process is conducted according to the SOP and reviews the testing results to ensure that the batch meets quality specifications.
  • Production Supervisor: Oversees the entire sampling process, ensures that proper sampling procedures are followed, and resolves any issues that arise during the sampling process.

4. Accountability

The Capsule Manufacturing Supervisor is accountable for ensuring that the randomized sampling is conducted according to this SOP. The QA Manager is responsible for reviewing and approving the sampling process and ensuring that the results are in compliance with quality standards.

5. Procedure

5.1 Sample Size Determination

Before collecting samples, determine the sample size based on the following:

  1. Determine Sample Size

    1. Calculate the appropriate sample size based on batch size, the expected variability of the product, and the level of confidence required for the testing.
    2. Consult standard sampling tables or quality control guidelines to determine the minimum number of samples required for the batch size.
  2. Confirm Sampling Requirements

    1. Ensure that the sample size is representative of the entire batch and that all critical quality attributes (e.g., size, weight, fill volume, appearance) will be covered in the sampling process.
    2. Ensure that the sampling plan adheres to industry standards or regulatory requirements for randomized sampling.

5.2 Randomized Sampling Process

Follow these steps to ensure that sampling is conducted randomly and represents the entire production batch:

  1. Ensure Random Selection

    1. Choose capsules randomly from different stages of the manufacturing process, ensuring that the selected capsules are representative of the entire batch.
    2. Do not select samples based on visual appearance to avoid selection bias.
  2. Collect the Samples

    1. Use clean and properly labeled sampling containers to collect the samples. Ensure that the capsules are not contaminated during the sampling process.
    2. Collect the samples from different locations in the batch, ensuring that they represent the entire manufacturing run.
  3. Record Sample Information

    1. Label each sample with the batch number, sampling time, and location. Ensure that the samples are stored in a clean, secure area until testing.
    2. Document all relevant details in the Sample Collection Log (Annexure-1), including the operator’s name, the time of sampling, and any other relevant observations.

5.3 Quality Control Testing

Once the samples have been collected, the following steps must be followed to test the capsules for compliance:

  1. Test the Samples

    1. QC will perform the necessary tests on the samples to evaluate the critical quality attributes, such as size, weight, fill volume, and appearance.
    2. Tests should be performed according to the predefined specifications for the capsules, ensuring that they meet the required standards.
  2. Analyze Test Results

    1. Analyze the test results to determine whether the capsules meet the established quality standards.
    2. If the results are within acceptable limits, the batch is deemed to pass the randomized sampling test and can proceed to the next stage of production.
    3. If the results are outside the acceptable limits, identify the cause of the deviation and take corrective actions.
  3. Document the Results

    1. Document all test results, including any deviations found, in the Sampling and Testing Report (Annexure-2).
    2. Ensure that all documentation is reviewed and signed by the responsible QC team member.

5.4 Handling Deviations and Corrective Actions

If the sampled capsules do not meet the quality specifications, follow these steps:

  1. Identify the Cause of Deviation

    1. Investigate the root cause of the deviation by reviewing the manufacturing process, materials, and equipment used during production.
    2. Consult with the production team to determine if any environmental factors, machine settings, or raw material issues contributed to the deviation.
  2. Implement Corrective Actions

    1. Take corrective actions, such as adjusting equipment settings, modifying the process, or addressing raw material issues, to prevent recurrence of the deviation.
    2. Retest the batch or affected samples after corrective actions are implemented to confirm that the issue has been resolved.
  3. Document the Deviation and Corrective Actions

    1. Record all deviations and corrective actions in the Deviation Log (Annexure-3) for future reference and regulatory compliance.

5.5 Final Approval and Release

Once the randomized sampling has been completed and any necessary corrective actions have been taken, the following steps must be taken:

  1. QA Review

    1. The QA team reviews the sampling results and corrective actions taken, ensuring that the batch meets the required quality specifications.
  2. Approval for Next Stage

    1. If the batch passes the randomized sampling and testing, the batch is approved for the next stage of production or packaging.

6. Abbreviations

  • SOP: Standard Operating Procedure
  • GMP: Good Manufacturing Practice
  • QC: Quality Control
  • QA: Quality Assurance
  • BPR: Batch Production Record

7. Documents

  1. Sample Collection Log (Annexure-1)
  2. Sampling and Testing Report (Annexure-2)
  3. Deviation Log (Annexure-3)

8. References

  • USP <1163> – Pharmaceutical Dosage Forms: Capsules
  • FDA Guidelines for Capsule Manufacturing
  • Good Manufacturing Practice (GMP) Guidelines

9. SOP Version

Version: 2.0

10. Approval Section

Prepared By Checked By Approved By
Signature
Date
Name
Designation
Department

11. Annexures

Annexure-1: Sample Collection Log

Sample ID Sample Location Sample Time Collected By Batch ID
Sample 001 Line 1 10:00 AM John Doe Batch 001
Sample 002 Line 2 10:15 AM Jane Smith Batch 001

Annexure-2: Sampling and Testing Report

Sample ID Test Parameter Test Result Deviations Corrective Action
Sample 001 Capsule Weight 500 mg No None
Sample 002 Fill Volume Standard No None

Annexure-3: Deviation Log

Deviation ID Batch ID Description Corrective Action Operator Approval Status
DEV-001 Batch 001 Capsule weight outside acceptable range Recalibrated machine John Doe Approved

Revision History:

Revision Date Revision No. Revision Details Reason for Revision Approved By
01/01/2024 1.0 Initial Version New SOP Creation QA Head
01/02/2025 2.0 Updated sampling procedures and documentation Standardization QA Head
]]>
Capsule: SOP for Visual Inspection of Capsule Sealing – V 2.0 https://www.pharmasop.in/capsule-sop-for-visual-inspection-of-capsule-sealing-v-2-0/ Sun, 30 Mar 2025 21:16:00 +0000 https://www.pharmasop.in/?p=9476 Read More “Capsule: SOP for Visual Inspection of Capsule Sealing – V 2.0” »

]]>
Capsule: SOP for Visual Inspection of Capsule Sealing – V 2.0

Standard Operating Procedure for Visual Inspection of Capsule Sealing

Department Capsule Manufacturing
SOP No. SOP/CM/103/2025
Supersedes SOP/CM/103/2022
Page No. Page 1 of 6
Issue Date 01/02/2025
Effective Date 05/02/2025
Review Date 01/02/2026

1. Purpose

The purpose of this SOP is to establish the procedure for the visual inspection of capsule sealing to ensure that capsules are sealed correctly, without leaks or defects. Proper capsule sealing is essential for maintaining the quality, stability, and safety of the product.

2. Scope

This SOP applies to the visual inspection of capsules during the sealing process. It includes the inspection of capsules for sealing integrity, ensuring that no leaks or improper seals are present before further processing or packaging.

3. Responsibilities

  • Production Operators: Responsible for visually inspecting capsules for sealing integrity during and after the sealing process. Operators must identify defects such as incomplete seals, cracks, or leaks.
  • Quality Control (QC) Team: Responsible for overseeing the inspection process, performing random spot checks, and verifying that the capsules meet quality standards for sealing.
  • Quality Assurance (QA) Team: Ensures the SOP is followed, reviews inspection records, and approves batches that meet sealing specifications for release.
  • Production Supervisor: Oversees the visual inspection process, ensures operators are trained in identifying seal defects, and resolves issues that arise during inspections.

4. Accountability

The Capsule Manufacturing Supervisor is accountable for ensuring that visual inspections of capsules are conducted correctly. The QA Manager is responsible for reviewing the inspection results and ensuring that the batch meets the required sealing specifications before release.

5. Procedure

5.1 Visual Inspection Setup

Before performing the visual inspection, ensure the following steps are completed:

  1. Prepare Inspection Area

    1. Ensure the inspection area is well-lit and clean. Proper lighting is essential for detecting seal defects, including incomplete or damaged seals.
    2. Set up the inspection station with clean tools and ensure that inspectors have access to necessary documentation (e.g., batch production record, inspection checklist).
  2. Verify Equipment Functionality

    1. Ensure that the sealing machine is properly calibrated and functioning according to the manufacturer’s specifications. This includes checking temperature settings, pressure, and sealing time.
    2. Verify that the capsule inspection equipment is in good working order, particularly if automated visual inspection systems are used.

5.2 Conducting the Visual Inspection

Follow these steps for visual inspection of capsule sealing:

  1. Inspect Seals for Completeness

    1. Check that each capsule has a complete and intact seal with no gaps, cracks, or visible openings.
    2. Inspect capsules for any incomplete seals that may cause leakage, contamination, or product loss during packaging.
  2. Check for Leaks

    1. Check the capsules for leaks by applying pressure or using appropriate equipment (e.g., vacuum or pressure test equipment) to identify compromised seals.
    2. Use visual inspection for leaks by looking for any product leakage from the capsule after it has been sealed.
  3. Inspect for Cracks or Damage

    1. Look for any cracks, chips, or deformation of the capsule shell that could impact product quality or lead to contamination during storage or transport.
    2. Inspect both the body and cap of the capsule to ensure that they are intact and there is no damage that could affect their functionality.
  4. Check for Proper Alignment

    1. Ensure that the capsule body and cap are aligned correctly, with no offset or misalignment that could result in an incomplete or defective seal.

5.3 Documentation of Inspection Results

Record the results of the visual inspection as follows:

  1. Record Inspection Findings

    1. Document the number of capsules inspected, the number of defective capsules, and the type of defect found (e.g., incomplete seals, cracks, leaks) in the Capsule Sealing Inspection Log (Annexure-1).
    2. For automated inspection systems, ensure that the inspection data is logged and stored for review.
  2. Retest Defective Capsules

    1. If defects are found, re-inspect the defective capsules manually or by using other inspection equipment to verify the severity of the issue.
    2. Document any corrective actions taken to resolve the issues, such as recalibrating equipment or adjusting sealing parameters.

5.4 Handling Defective Capsules

If defective capsules are identified, handle them as follows:

  1. Segregate Defective Capsules

    1. Immediately separate defective capsules from the acceptable batch to prevent contamination during packaging.
    2. Label the containers with the rejected capsules clearly, indicating the reason for rejection (e.g., incomplete seal, cracked shell, leakage).
  2. Reject and Document

    1. Reject the defective capsules based on the severity of the defect, and document the rejection in the Reject Log (Annexure-2).
    2. Investigate the cause of the defect and take corrective actions to prevent recurrence, such as adjusting machine settings or changing raw materials.

5.5 Final Approval for Packaging

Once the visual inspection is complete and all defective capsules have been addressed, proceed as follows:

  1. QA Review

    1. The QA team should review the inspection results, including any corrective actions taken, to ensure that the sealing process meets quality standards.
  2. Approval for Packaging

    1. If the capsules meet the required sealing specifications, the batch is approved for packaging and labeling.

6. Abbreviations

  • SOP: Standard Operating Procedure
  • GMP: Good Manufacturing Practice
  • QC: Quality Control
  • QA: Quality Assurance
  • BPR: Batch Production Record

7. Documents

  1. Capsule Sealing Inspection Log (Annexure-1)
  2. Reject Log (Annexure-2)

8. References

  • USP <1163> – Pharmaceutical Dosage Forms: Capsules
  • FDA Guidelines for Capsule Manufacturing
  • Good Manufacturing Practice (GMP) Guidelines

9. SOP Version

Version: 2.0

10. Approval Section

Prepared By Checked By Approved By
Signature
Date
Name
Designation
Department

11. Annexures

Annexure-1: Capsule Sealing Inspection Log

Sample ID Capsule Seal Integrity Defects Found Operator
Sample 001 Pass None John Doe
Sample 002 You said:
Continue
ChatGPT said:
html
Copy

Fail Cracked capsule Jane Smith

Annexure-2: Reject Log

Batch ID Reason for Rejection Number of Rejected Capsules Corrective Action
Batch 001 Incomplete seal 20 Recalibrated sealing machine

Revision History:

Revision Date Revision No. Revision Details Reason for Revision Approved By
01/01/2024 1.0 Initial Version New SOP Creation QA Head
01/02/2025 2.0 Updated inspection criteria and corrective actions Standardization QA Head
]]>
Capsule: SOP for Inline QC Testing During Capsule Manufacturing – V 2.0 https://www.pharmasop.in/capsule-sop-for-inline-qc-testing-during-capsule-manufacturing-v-2-0/ Sun, 30 Mar 2025 14:26:00 +0000 https://www.pharmasop.in/?p=9475 Read More “Capsule: SOP for Inline QC Testing During Capsule Manufacturing – V 2.0” »

]]>
Capsule: SOP for Inline QC Testing During Capsule Manufacturing – V 2.0

Standard Operating Procedure for Inline QC Testing During Capsule Manufacturing

Department Capsule Manufacturing
SOP No. SOP/CM/102/2025
Supersedes SOP/CM/102/2022
Page No. Page 1 of 6
Issue Date 01/02/2025
Effective Date 05/02/2025
Review Date 01/02/2026

1. Purpose

The purpose of this SOP is to define the procedure for conducting inline quality control (QC) testing during the capsule manufacturing process. Inline QC testing ensures that capsule manufacturing processes are continuously monitored for product quality, compliance with specifications, and adherence to Good Manufacturing Practices (GMP).

2. Scope

This SOP applies to the capsule manufacturing process where inline QC testing is implemented. It includes the monitoring of critical quality attributes, including size, weight, fill volume, and appearance, as well as the detection of deviations from quality standards.

3. Responsibilities

  • Production Operators: Responsible for conducting inline QC tests during the manufacturing process and ensuring that test results meet the required specifications.
  • Quality Control (QC) Team: Responsible for reviewing inline test results, verifying compliance, and taking appropriate actions for deviations detected during manufacturing.
  • Quality Assurance (QA) Team: Ensures that the inline QC testing procedures are followed in compliance with GMP and regulatory requirements.
  • Production Supervisor: Responsible for overseeing the inline QC testing process, ensuring that the tests are conducted properly, and troubleshooting any issues that arise during testing.

4. Accountability

The Capsule Manufacturing Supervisor is accountable for ensuring that inline QC tests are conducted as per the SOP. The QA Manager is responsible for reviewing the inline testing results and ensuring compliance with GMP and regulatory requirements.

5. Procedure

5.1 Inline QC Testing Parameters

Before initiating inline QC testing, the following parameters should be defined:

  1. Determine Quality Attributes

    1. Identify critical quality attributes for capsule production, including size, weight, fill volume, appearance, and integrity.
    2. Establish acceptable limits for each attribute based on product specifications and regulatory requirements.
  2. Set Test Frequency

    1. Determine the frequency of inline QC testing based on batch size, production speed, and criticality of the quality attributes being monitored.
    2. Set testing intervals to ensure adequate sampling and monitoring throughout the production run.

5.2 Setting Up Inline QC Testing Equipment

To ensure accurate inline testing, ensure that the necessary equipment is properly set up:

  1. Verify Calibration of Equipment

    1. Before testing, ensure that the inline QC testing equipment is properly calibrated to measure parameters such as capsule weight, size, and fill volume.
    2. Use calibrated test instruments and verify the calibration regularly to maintain testing accuracy.
  2. Check Equipment Condition

    1. Ensure that all equipment used for inline testing is clean, properly maintained, and functioning as intended.
    2. Inspect sensors, cameras, or other monitoring devices used in inline QC to ensure they are working properly without obstructions.

5.3 Performing Inline QC Testing During Capsule Manufacturing

Once the equipment is set up, proceed with the inline QC testing process:

  1. Monitor Capsule Attributes

    1. Monitor critical capsule attributes such as size, weight, fill volume, and appearance at regular intervals during the manufacturing process.
    2. Use inline measurement systems or automated machines to capture data on capsule attributes.
  2. Document Test Results

    1. Record the results of each inline QC test in the Inline QC Testing Log (Annexure-1), including test parameters, date, time, and any deviations from the specified limits.
    2. Ensure that all data is signed, dated, and reviewed by a responsible person to maintain traceability and accountability.
  3. Analyze Test Data

    1. Analyze the collected data to determine if the capsules meet the required quality standards.
    2. Track trends over time to identify any patterns that could indicate deviations or issues with the manufacturing process.

5.4 Handling Deviations in Inline QC Testing

If any deviations or out-of-spec results are detected during inline QC testing, follow these steps:

  1. Identify the Cause of Deviation

    1. Investigate the cause of the deviation by reviewing the process, materials, equipment, and environmental conditions.
    2. Consult with the production team to determine if the deviation is related to equipment malfunction, process variation, or raw material issues.
  2. Implement Corrective Actions

    1. Take corrective actions based on the identified cause, such as adjusting equipment settings, changing materials, or modifying the manufacturing process.
    2. Re-test the affected capsules to ensure that the corrective actions have successfully resolved the deviation.
  3. Record Deviation and Corrective Actions

    1. Document all deviations, corrective actions, and retesting results in the Deviation Log (Annexure-2) to maintain a record for future audits or inspections.

5.5 Quality Control Review and Final Approval

Once the inline QC testing is complete, follow these steps:

  1. QA Review of Test Results

    1. The QA team should review the results of the inline QC testing, ensuring that all capsules meet the required quality standards.
    2. Ensure that any deviations were properly addressed and documented.
  2. Approval for Next Production Step

    1. If the inline QC testing results are satisfactory, approve the batch to proceed to the next manufacturing step or packaging.

6. Abbreviations

  • SOP: Standard Operating Procedure
  • GMP: Good Manufacturing Practice
  • QC: Quality Control
  • QA: Quality Assurance
  • BPR: Batch Production Record

7. Documents

  1. Inline QC Testing Log (Annexure-1)
  2. Deviation Log (Annexure-2)
  3. Batch Production Record (BPR) (Annexure-3)

8. References

  • USP <1163> – Pharmaceutical Dosage Forms: Capsules
  • FDA Guidelines for Capsule Manufacturing
  • Good Manufacturing Practice (GMP) Guidelines

9. SOP Version

Version: 2.0

10. Approval Section

Prepared By Checked By Approved By
Signature
Date
Name
Designation
Department

11. Annexures

Annexure-1: Inline QC Testing Log

Sample ID Test Parameter Test Result Deviation Corrective Action Taken Operator
Sample 001 Capsule Weight 500 mg No None John Doe
Sample 002 Fill Volume Standard No None Jane Smith

Annexure-2: Deviation Log

Deviation ID Batch ID Description Corrective Action Operator Approval Status
DEV-001 Batch 001 Capsule weight outside acceptable range Recalibrated filling machine and adjusted speed John Doe Approved

Annexure-3: Batch Production Record (BPR)

Batch ID Capsule Weight Fill Volume Inspection Results Corrective Actions
Batch 001 500 mg Standard Pass None

Revision History:

Revision Date Revision No. Revision Details Reason for Revision Approved By
01/01/2024 1.0 Initial Version New SOP Creation QA Head
01/02/2025 2.0 Updated inline QC testing procedures Standardization QA Head
]]>
Capsule: SOP for Moisture Content Testing of Capsules During Manufacturing – V 2.0 https://www.pharmasop.in/capsule-sop-for-moisture-content-testing-of-capsules-during-manufacturing-v-2-0/ Sun, 30 Mar 2025 07:36:00 +0000 https://www.pharmasop.in/?p=9474 Read More “Capsule: SOP for Moisture Content Testing of Capsules During Manufacturing – V 2.0” »

]]>
Capsule: SOP for Moisture Content Testing of Capsules During Manufacturing – V 2.0

Standard Operating Procedure for Moisture Content Testing of Capsules During Manufacturing

Department Capsule Manufacturing
SOP No. SOP/CM/101/2025
Supersedes SOP/CM/101/2022
Page No. Page 1 of 6
Issue Date 01/02/2025
Effective Date 05/02/2025
Review Date 01/02/2026

1. Purpose

The purpose of this SOP is to define the procedure for testing the moisture content of capsules during the manufacturing process. Accurate moisture content is essential for ensuring the stability, integrity, and quality of the capsules.

2. Scope

This SOP applies to the process of testing moisture content in capsules during manufacturing. It covers the steps for sampling, testing, and evaluating the moisture content to ensure that it meets the established specifications.

3. Responsibilities

  • Production Operators: Responsible for collecting capsule samples and conducting initial moisture content testing during production runs.
  • Quality Control (QC) Team: Responsible for overseeing the moisture content testing process, ensuring that tests are performed according to the SOP, and reviewing test results.
  • Quality Assurance (QA) Team: Ensures the SOP is followed and approves the final test results and batch release based on moisture content specifications.
  • Production Supervisor: Oversees the moisture content testing procedure, ensures all equipment is calibrated and functioning, and ensures compliance with SOP.

4. Accountability

The Capsule Manufacturing Supervisor is accountable for ensuring that moisture content testing is performed correctly and that capsules meet the required specifications. The QA Manager is responsible for reviewing and approving the results of moisture content testing.

5. Procedure

5.1 Sample Collection for Moisture Content Testing

Before conducting the moisture content test, ensure the following steps are followed:

  1. Determine Sample Size

    1. Determine the number of capsules to be sampled for testing, ensuring that the sample size is statistically representative of the entire batch.
    2. Ensure that the sample size is adequate to obtain reliable moisture content results, typically 10-20 capsules depending on batch size.
  2. Random Sampling

    1. Randomly select the sample capsules from different parts of the batch to ensure an accurate representation of the entire production run.
    2. Label the capsules clearly to avoid mix-ups and maintain traceability.

5.2 Moisture Content Testing Procedure

Once the sample has been collected, follow these steps to test the moisture content of the capsules:

  1. Prepare the Moisture Content Testing Equipment

    1. Ensure the moisture analyzer is calibrated according to the manufacturer’s instructions. Verify the equipment’s accuracy using a standard moisture content reference sample.
    2. Clean the moisture analyzer and ensure it is free from contaminants that may affect the test results.
  2. Test the Capsules

    1. Place the selected capsules on the moisture analyzer. If the capsules are filled with an active ingredient, ensure that the fill material does not interfere with the testing process.
    2. Activate the moisture analyzer and begin the test, ensuring that the correct testing parameters are set based on the capsule material (e.g., gelatin, HPMC) and formulation.
  3. Record the Results

    1. Record the moisture content percentage for each capsule sample tested. Ensure that the results are noted in the Moisture Content Test Log (Annexure-1).
    2. Compare the test results with the established moisture content specifications to determine if they fall within the acceptable range.

5.3 Handling Deviations

If the moisture content is outside the acceptable range, follow these steps:

  1. Identify the Cause

    1. Investigate the root cause of the deviation. Possible causes may include improper drying, excessive humidity during manufacturing, or formulation inconsistencies.
    2. Evaluate whether the deviation is related to environmental conditions, equipment malfunction, or process variation.
  2. Take Corrective Action

    1. Adjust the environmental conditions, such as humidity or temperature, to bring the moisture content back within the acceptable range.
    2. If the issue is equipment-related, perform the necessary adjustments, calibration, or maintenance to restore proper operation.
  3. Retest the Capsules

    1. After corrective actions are implemented, retest the capsules to confirm that the moisture content is within specification.
    2. Continue testing at regular intervals throughout the manufacturing process to ensure that the moisture content remains stable.

5.4 Quality Control and Documentation

Ensure proper documentation and follow-up actions as part of the moisture content testing process:

  1. Maintain Test Records

    1. Document all moisture content test results in the Moisture Content Test Log (Annexure-1), including the sample IDs, test results, and any deviations observed.
    2. Ensure that all documentation is signed and dated by the responsible operator and reviewed by the QA team.
  2. Submit Reports for Review

    1. Submit the test results, along with any corrective actions taken, to the QA department for review and final approval.

5.5 Final Approval

Once the moisture content has been successfully tested and meets specifications, proceed as follows:

  1. QA Review

    1. The QA team will review the moisture content test results to ensure they meet the defined standards and are compliant with GMP guidelines.
  2. Approval for Further Processing

    1. If the moisture content meets the requirements, the batch can proceed to the next manufacturing step or packaging.

6. Abbreviations

  • SOP: Standard Operating Procedure
  • GMP: Good Manufacturing Practice
  • QC: Quality Control
  • QA: Quality Assurance

7. Documents

  1. Moisture Content Test Log (Annexure-1)

8. References

  • USP <1163> – Pharmaceutical Dosage Forms: Capsules
  • FDA Guidelines for Capsule Manufacturing
  • Good Manufacturing Practice (GMP) Guidelines

9. SOP Version

Version: 2.0

10. Approval Section

Prepared By Checked By Approved By
Signature
Date
Name
Designation
Department

11. Annexures

Annexure-1: Moisture Content Test Log

Sample ID Moisture Content (%) Deviation Corrective Action Taken Operator
Sample 001 5.2% No None John Doe

Revision History:

Revision Date Revision No. Revision Details Reason for Revision Approved By
01/01/2024 1.0 Initial Version New SOP Creation QA Head
01/02/2025 2.0 Updated sampling and testing process Standardization QA Head
]]>
Capsule: SOP for Maintaining Capsule Appearance During Packaging – V 2.0 https://www.pharmasop.in/capsule-sop-for-maintaining-capsule-appearance-during-packaging-v-2-0/ Sun, 30 Mar 2025 00:46:00 +0000 https://www.pharmasop.in/?p=9473 Read More “Capsule: SOP for Maintaining Capsule Appearance During Packaging – V 2.0” »

]]>
Capsule: SOP for Maintaining Capsule Appearance During Packaging – V 2.0

Standard Operating Procedure for Maintaining Capsule Appearance During Packaging

Department Capsule Manufacturing
SOP No. SOP/CM/100/2025
Supersedes SOP/CM/100/2022
Page No. Page 1 of 6
Issue Date 01/02/2025
Effective Date 05/02/2025
Review Date 01/02/2026

1. Purpose

The purpose of this SOP is to outline the process for maintaining capsule appearance during packaging. Ensuring that capsules retain their appearance throughout the packaging process is crucial for maintaining product quality, appearance, and compliance with regulatory standards.

2. Scope

This SOP applies to all capsule manufacturing processes that include the packaging of finished capsules. It covers the steps for inspecting, handling, and packaging capsules to ensure they retain their appearance, including size, shape, color, and integrity.

3. Responsibilities

  • Production Operators: Responsible for inspecting capsules during the packaging process and ensuring they meet the required appearance specifications.
  • Quality Control (QC) Team: Responsible for performing random inspections of packaged capsules and ensuring that they meet appearance and quality standards.
  • Quality Assurance (QA) Team: Ensures that the SOP is followed and that the final product complies with regulatory and appearance standards.
  • Production Supervisor: Oversees the entire packaging process, ensures compliance with the SOP, and resolves any appearance-related issues that arise during packaging.

4. Accountability

The Capsule Manufacturing Supervisor is accountable for ensuring that the capsule appearance is maintained during the packaging process. The QA Manager is responsible for reviewing the packaging results and ensuring compliance with all appearance standards.

5. Procedure

5.1 Preparing Capsules for Packaging

Before beginning the packaging process, ensure that the following steps are completed:

  1. Inspect Capsule Appearance

    1. Inspect a sample of capsules to ensure that they meet the specified size, shape, color, and integrity requirements.
    2. Look for any defects, such as cracks, discoloration, or uneven capsule surfaces. Any capsules with appearance defects should be segregated for rejection.
  2. Ensure Proper Handling

    1. Handle capsules with care to avoid causing damage or altering their appearance. Use soft and clean surfaces for capsule handling.
    2. Ensure that the capsules are not exposed to excessive heat, humidity, or light, as these factors can affect the appearance of the capsules.

5.2 Capsule Packaging Process

Once the capsules are ready for packaging, follow these steps:

  1. Set Up Packaging Equipment

    1. Set up the packaging line, ensuring that all equipment, including the capsule filling machine, capsule inspection machine, and packaging materials, are clean and ready for use.
    2. Ensure that the packaging machine settings are adjusted to match the size and specifications of the capsules.
  2. Monitor Capsule Appearance During Packaging

    1. Monitor the appearance of capsules as they are being fed into the packaging machine. Ensure that capsules are correctly aligned, and check for any damaged or defective capsules.
    2. Inspect the final packaging for any issues related to the appearance of the capsules, such as cracked, broken, or discolored capsules.
  3. Adjust Equipment if Necessary

    1. If any defects are detected during the packaging process, stop the machine and adjust the settings. Investigate the cause of the appearance defects (e.g., machine malfunction, improper handling, or environmental factors).
    2. Recalibrate equipment or adjust the packaging speed if necessary to maintain capsule appearance.

5.3 Capsule Quality Control and Final Inspection

Once the capsules have been packaged, perform the following quality control steps:

  1. Random Sampling

    1. Perform random sampling of packaged capsules for visual inspection. Ensure that a representative sample is selected to check for any appearance defects.
    2. Check capsules for consistency in size, color, shape, and surface integrity. Any defective capsules should be rejected and documented.
  2. Inspect Packaging Integrity

    1. Ensure that the capsules are properly sealed and that the packaging is intact. Check for any signs of contamination, damage, or tampering with the packaging.
    2. Document the inspection results, including the number of capsules inspected, any defects found, and the actions taken.
  3. Rejection of Defective Capsules

    1. If any capsules do not meet the appearance standards, they should be rejected and properly disposed of in accordance with the rejection procedure.
    2. Document the rejection in the Reject Log (Annexure-1) and investigate the cause of the defects to prevent recurrence.

5.4 Documentation and Reporting

It is essential to document all steps in the process to ensure traceability and compliance:

  1. Maintain Packaging Records

    1. Document all packaging details, including batch number, capsule specifications, packaging materials used, and inspection results in the Batch Production Record (BPR) (Annexure-2).
  2. Record Defective Capsules

    1. Record any defective capsules, including the reason for rejection and the corrective actions taken, in the Reject Log (Annexure-1).

5.5 Final Approval and Release

After completing the inspection and ensuring the capsules meet the required appearance standards, the following steps should be taken:

  1. QA Review

    1. The QA team should review all packaging and inspection records to ensure that the capsules meet the required appearance standards and are compliant with clinical trial or commercial requirements.
  2. Approval for Release

    1. If the capsules pass the final inspection and are deemed suitable for use, the batch is approved for release and packaging.

6. Abbreviations

  • SOP: Standard Operating Procedure
  • GMP: Good Manufacturing Practice
  • QC: Quality Control
  • QA: Quality Assurance
  • BPR: Batch Production Record

7. Documents

  1. Batch Production Record (BPR) (Annexure-2)
  2. Reject Log (Annexure-1)

8. References

  • USP <1163> – Pharmaceutical Dosage Forms: Capsules
  • FDA Guidelines for Capsule Manufacturing
  • Good Manufacturing Practice (GMP) Guidelines

9. SOP Version

Version: 2.0

10. Approval Section

Prepared By Checked
You said:
Continue
ChatGPT said:
html
Copy
By
Approved By
Signature
Date
Name
Designation
Department

11. Annexures

Annexure-1: Reject Log

Batch ID Reason for Rejection Number of Rejected Capsules Corrective Action
Batch 001 Capsules with color variation 50 Recalibrated color sorting machine

Annexure-2: Batch Production Record (BPR)

Batch ID Capsule Specifications Appearance Check Rejected Capsules Corrective Actions
Batch 001 Size 0, White Pass 0 None

Revision History:

Revision Date Revision No. Revision Details Reason for Revision Approved By
01/01/2024 1.0 Initial Version New SOP Creation QA Head
01/02/2025 2.0 Updated procedures for handling defective capsules and corrective actions Standardization QA Head
]]>