Tablets: SOP for Tablet Compression Process – V 2.0

Posted on By

Tablets: SOP for Tablet Compression Process – V 2.0

Standard Operating Procedure for Tablet Compression Process

Department Tablet
SOP No. SOP/TAB/007/2025
Supersedes SOP/TAB/007/2022
Page No. Page 1 of 8
Issue Date 15/03/2025
Effective Date 20/03/2025
Review Date 15/03/2026

1. Purpose

To establish a standardized procedure for the tablet compression process, ensuring that tablets are compressed to the required weight, hardness, and other quality specifications.

2. Scope

This SOP applies to the tablet compression process, including machine setup, tablet compression, and monitoring of tablet quality during the process.

3. Responsibilities

  • Manufacturing Personnel: Responsible for setting up and operating the tablet compression machine, ensuring proper tablet compression parameters are followed.
  • Quality Control (QC): Responsible for performing in-process checks on tablet weight, hardness, and other specifications during the compression process.
  • Quality Assurance (QA): Responsible for overseeing the compliance with this SOP and ensuring the tablet compression process meets regulatory and internal quality standards.

4. Accountability

The Production Manager is accountable for the proper execution of the tablet compression process. The QA Manager ensures compliance with this SOP and regulatory standards.

5. Procedure

5.1 Tablet Compression Machine Setup

  1. Ensure the tablet compression machine is clean and free of any previous product residue.
  2. Verify that the die and
punch sizes correspond to the specifications required for the current batch.
  • Check that the tablet press is calibrated and operational, including ensuring proper pressure and speed settings are in place.
  • Ensure all settings, such as tablet weight, hardness, and thickness, are input into the system and aligned with the formulation specifications.
  • 5.2 Loading Granules into Compression Machine

    1. Transfer the lubricated granules into the hopper of the tablet compression machine.
    2. Ensure the granules are evenly distributed in the hopper, preventing blockages or uneven filling of the tablet dies.
    3. Check that the granules have the correct consistency and moisture content for tablet compression. If necessary, adjust the formulation or parameters before loading.

    5.3 Tablet Compression

    1. Start the tablet compression process and monitor the machine to ensure tablets are being compressed properly.
    2. Adjust the compression pressure if necessary to achieve the desired tablet hardness. Maintain consistency in the tablet weight and size throughout the process.
    3. Ensure that the tablet edges are smooth and free from defects such as capping or lamination.
    4. Perform regular checks on the compression force to ensure it remains within the specified range.

    5.4 In-Process Quality Control

    1. Monitor the tablet compression process regularly, checking the weight, hardness, and appearance of tablets at defined intervals.
    2. Perform in-process checks for tablet weight, hardness, and thickness using calibrated instruments, and compare with specifications.
    3. Take sample tablets for disintegration and dissolution testing, if required by the formulation guidelines.
    4. Record all results from in-process quality checks in the batch record (Annexure-1).
    5. If any abnormalities are detected, adjust machine parameters accordingly and document any deviations from the standard process.

    5.5 Monitoring Tablet Quality

    1. During the compression process, monitor tablet characteristics such as weight variation, hardness, and thickness to ensure consistency.
    2. Ensure that tablets meet the required hardness range as per the formulation requirements.
    3. Document any corrective actions taken if the tablet quality does not meet specifications.

    5.6 Tablet Collection and Storage

    1. Once the tablets are compressed, collect them in designated bins or containers for the next processing step (e.g., coating or packaging).
    2. Ensure that tablets are stored in a clean, dry environment to avoid contamination or degradation before further processing.

    5.7 Equipment Shutdown and Cleaning

    1. Once tablet compression is complete, shut down the machine and clean it according to the approved cleaning SOP.
    2. Ensure that all parts that come into contact with the product are thoroughly cleaned to prevent cross-contamination between batches.

    5.8 Documentation and Record-Keeping

    1. Document all tablet compression parameters, including compression pressure, speed, tablet weight, and hardness, in the batch record.
    2. Sign off on the batch record to confirm the completion of the tablet compression process.
    3. Maintain detailed records of in-process checks, deviations, and any corrective actions taken during the tablet compression process.

    6. Abbreviations

    • SOP: Standard Operating Procedure
    • GMP: Good Manufacturing Practice
    • QC: Quality Control
    • QA: Quality Assurance
    • CoA: Certificate of Analysis

    7. Documents

    1. Tablet Compression Batch Record (Annexure-1)
    2. Tablet Quality Control Log (Annexure-2)

    8. References

    • 21 CFR Part 211 – Current Good Manufacturing Practice for Finished Pharmaceuticals (US FDA)
    • EU GMP Guidelines Part I – Basic Requirements for Medicinal Products
    • ICH Q7 – Good Manufacturing Practice Guide for Active Pharmaceutical Ingredients

    9. SOP Version

    Version: 2.0

    10. Approval Section

    Prepared By Checked By Approved By
    Signature
    Date
    Name
    Designation
    Department

    11. Annexures

    Annexure-1: Tablet Compression Batch Record

    Batch Number Tablet Type Compression Pressure Tablet Weight Tablet Hardness Remarks
    Batch 001 Tablet A 50 kN 500 mg 8 kg Within specifications
    Batch 002 Tablet B 55 kN 510 mg 8.5 kg Minor deviation in weight

    Annexure-2: Tablet Quality Control Log

    Batch Number Test Performed Result Test Date QC Personnel
    Batch 001 Tablet Weight Pass 15/03/2025 John Doe
    Batch 002 Tablet Hardness Pass 16/03/2025 Jane Smith

    Revision History:

    Revision Date Revision No. Revision Details Reason for Revision Approved By
    01/01/2024 1.0 Initial Version New SOP Creation QA Head
    01/02/2025 2.0 Updated Compression Parameters Standardization of Tablet Compression Process QA Head
    See also  Tablets: SOP for Ensuring Batch Code Legibility on Packaging - V 2.0
    Tablet Manufacturing V2.0 Tags:GMP tablet manufacturing SOP, SOP for tablet production, SOP for tablet quality control, SOP tablet inspection process, SOP tablet packing and sealing, Tablet batch record review, Tablet blending SOP, Tablet cleaning and maintenance, Tablet coating procedure, Tablet compression SOP, Tablet disintegration test procedure, Tablet dissolution procedure, Tablet formulation SOP, Tablet friability testing SOP, Tablet labeling and packaging SOP, Tablet manufacturing equipment SOP, Tablet manufacturing SOP, Tablet manufacturing SOPs, Tablet packaging SOP, Tablet production procedure, Tablet quality assurance SOP, Tablet quality control SOP, Tablet sampling and in-process testing SOP, Tablet stability testing SOP, Tablet storage and handling procedure, Tablet uniformity testing procedure, Tablet weight variation SOP

    Post navigation

    Previous Post: SOP for Hematological Analysis in Preclinical Studies
    Next Post: SOP for Verification of Certificate of Analysis (CoA) During Material Receipt – V 2.0

    Standard Operating Procedures V 1.0

    • Aerosols
    • Analytical Method Development
    • Bioequivalence Bioavailability Study
    • Capsule Formulation
    • Clinical Studies
    • Creams
    • Data Integrity
    • Dental Dosage Forms
    • Drug Discovery
    • Environment, Health and Safety
    • Formulation Development
    • Gels
    • Good Distribution Practice
    • Good Warehousing Practices
    • In-Process Control
    • Injectables
    • Liquid Orals
    • Liposome and Emulsion Formulations
    • Lotions
    • Lyophilized Products
    • Maintenance Dept.
    • Medical Devices
    • Metered-Dose Inhaler
    • Microbiology Testing
    • Nanoparticle Formulation
    • Nasal Spray Formulations
    • Nebulizers
    • Ocular (Eye) Dosage Forms
    • Ointments
    • Otic (Ear) Dosage Forms
    • Pharmacovigilance
    • Powder & Granules
    • Purchase Departments
    • Quality Assurance
    • Quality Control
    • Raw Material Stores
    • Regulatory Affairs
    • Tablet Manufacturing
    • Rectal Dosage Forms
    • Transdermal Patches
    • Vaginal Dosage Forms
    • Validations and Qualifications

    Read SOPs in your Language:

     - 
    Bengali
     - 
    bn
    English
     - 
    en
    Gujarati
     - 
    gu
    Hindi
     - 
    hi
    Malayalam
     - 
    ml
    Marathi
     - 
    mr
    Punjabi
     - 
    pa
    Tamil
     - 
    ta
    Telugu
     - 
    te

    NEW! Revised SOPs – V 2.0

    • Aerosols V 2.0
    • Analytical Method Development V 2.0
    • API Manufacturing V 2.0
    • BA-BE Studies V 2.0
    • Biosimilars V 2.0
    • Capsules V 2.0
    • Creams V 2.0
    • Elixers V 2.0
    • Ointments V 2.0
    • Raw Material Warehouse V 2.0
    • Tablet Manufacturing V2.0

    New Publication: A must for All.

    Copyright © 2025 SOP Guide for Pharma.

    Powered by PressBook WordPress theme

    Go to mobile version