Standard Operating Procedure for Multi-Layer Tablet Manufacturing Process
Department | Tablet |
---|---|
SOP No. | SOP/TAB/065/2025 |
Supersedes | SOP/TAB/065/2022 |
Page No. | Page 1 of 6 |
Issue Date | 05/01/2026 |
Effective Date | 10/01/2026 |
Review Date | 05/01/2027 |
1. Purpose
To define the procedure for manufacturing multi-layer tablets, ensuring proper layer formation, uniformity, and the desired therapeutic release profile.
2. Scope
This SOP applies to the entire multi-layer tablet manufacturing process, including granulation, compression, and coating.
3. Responsibilities
- Manufacturing Personnel: Responsible for performing the multi-layer tablet manufacturing steps as outlined in this SOP.
- Quality Control (QC): Ensures the quality and uniformity of the multi-layer tablets by performing in-process testing and final product checks.
- Quality Assurance (QA): Ensures compliance with the SOP and approves the final product for release.
- Maintenance Personnel: Ensures that equipment used in the multi-layer tablet manufacturing process is calibrated and maintained.
4. Accountability
The Production Manager is accountable for ensuring that the multi-layer tablet manufacturing process is carried out according to this SOP. The QA Manager is responsible for overseeing compliance with this procedure.
5. Procedure
5.1 Preparation
- Ensure that all ingredients are weighed accurately as per the batch record.
- Check that the tablet press is set up correctly
with the appropriate tooling for multi-layer compression.
Prepare the granules for each layer according to the batch record specifications. Ensure proper blending of materials for uniformity.
Verify that the coating solution is ready and meets the required specifications.
5.2 Layer Compression
- Start by compressing the first layer of the tablet. Ensure that the compaction force is set correctly as per the batch record.
- Once the first layer is complete, stop the compression cycle and load the second layer’s material onto the tablet press.
- Compress the second layer with the same compaction force, ensuring uniform distribution.
- Repeat the above steps for any additional layers as required by the batch record.
5.3 Monitoring During Compression
- Monitor the tablet’s weight, thickness, and hardness at regular intervals during the compression process.
- Ensure that the tablets meet the required specifications for each layer’s weight and thickness.
- If the tablets do not meet specifications, adjust the compression force or material distribution and re-test.
5.4 Post-Compression Inspection
- Inspect the tablets for any visible defects, such as cracking or uneven layering.
- Ensure that all layers are intact and uniformly distributed.
- Conduct a hardness test on the tablets and ensure they meet the required specifications for tablet strength.
5.5 Coating
- Once the tablets pass the inspection, apply the coating as specified in the batch record.
- Ensure uniform coating by adjusting spray rate, air pressure, and pan speed during the coating process.
- After the coating is applied, inspect the tablets for coating uniformity and defects such as chipping or cracking.
5.6 Documentation
- Document the process, including weight, thickness, and hardness measurements, in the batch record (Annexure-1).
- Record any deviations in the deviation report (Annexure-2), including corrective actions taken.
- Ensure all records are signed, dated, and stored in compliance with company procedures.
5.7 Equipment Maintenance
- Perform routine maintenance on the tablet press and coating equipment to ensure they are operating properly.
- Document all calibration and maintenance activities in the equipment maintenance log (Annexure-3).
6. Abbreviations
- SOP: Standard Operating Procedure
- GMP: Good Manufacturing Practice
- QC: Quality Control
- QA: Quality Assurance
- API: Active Pharmaceutical Ingredient
7. Documents
- Batch Record (Annexure-1)
- Deviation Report (Annexure-2)
- Equipment Maintenance Log (Annexure-3)
8. References
- 21 CFR Part 211 – Current Good Manufacturing Practice for Finished Pharmaceuticals (US FDA)
- EU GMP Guidelines Part I – Basic Requirements for Medicinal Products
- ICH Q7 – Good Manufacturing Practice Guide for Active Pharmaceutical Ingredients
9. SOP Version
Version: 2.0
10. Approval Section
Prepared By | Checked By | Approved By | |
---|---|---|---|
Signature | |||
Date | |||
Name | |||
Designation | |||
Department |
11. Annexures
Annexure-1: Batch Record
Batch Number | Layer 1 Weight | Layer 2 Weight | Tablet Hardness | Comments |
---|---|---|---|---|
Batch 001 | 200 mg | 180 mg | 7 kg | No defects |
Annexure-2: Deviation Report
Deviation Date | Batch Number | Deviation Description | Corrective Action | Responsible Person |
---|---|---|---|---|
10/12/2025 | Batch 002 | Hardness out of specification | Adjusted compression force | John Doe |
Annexure-3: Equipment Maintenance Log
Maintenance Date | Equipment | Maintenance Performed | Performed By | Comments |
---|---|---|---|---|
12/12/2025 | Tablet Press | Calibration and Tooling Inspection | Jane Smith | Tooling in good condition |
Revision History:
Revision Date | Revision No. | Revision Details | Reason for Revision | Approved By |
---|---|---|---|---|
01/01/2024 | 1.0 | Initial Version | New SOP Creation | QA Head |
01/02/2025 | 2.0 | Updated Compression Settings | Improved Compression Efficiency | QA Head |