Standard Operating Procedure for Handling Returned Goods in Tablet Manufacturing

Department Tablet
SOP No. SOP/TAB/199/2025
Supersedes SOP/TAB/199/2022
Page No. Page 1 of 6
Issue Date 01/03/2026
Effective Date 06/03/2026
Review Date 01/03/2027

1. Purpose

To define the procedure for handling returned goods in tablet manufacturing, ensuring that all returned products are appropriately managed to maintain product integrity and comply with regulatory requirements.

2. Scope

This SOP applies to the handling, inspection, and documentation of returned goods in tablet manufacturing. It includes both finished products returned due to defects or customer complaints and raw materials returned due to quality issues or overstock.

3. Responsibilities

4. Accountability

The QA Manager is accountable for ensuring that the process for handling returned goods is followed in compliance with regulatory requirements. The Production Manager is accountable for ensuring that returned products are inspected and evaluated to determine if they can be reused or need to be discarded.

5. Procedure

5.1 Receiving Returned Goods

  1. When returned goods are received, immediately segregate them from other products to avoid any cross-contamination.
  2. Verify the reason for return by reviewing the return documentation or customer complaint records. All returns must be accompanied by a return authorization form (Annexure-2).
  3. Label all returned goods with the “Return” label, indicating the reason for return, batch number, and the date of receipt.
  4. Ensure that all returned products are placed in a designated quarantine area until further evaluation.

5.2 Inspection and Evaluation of Returned Goods

  1. Inspect all returned goods for visible defects or damages. If the returned goods are finished products, check for signs of damage, contamination, or expiry.
  2. For finished tablets, verify that the batch number and expiration date match the return documentation (Annexure-3).
  3. If returned raw materials are received, check the integrity of the packaging, the batch number, and the expiry date. Ensure the materials have not been tampered with or exposed to environmental factors (e.g., temperature or humidity) that could affect their quality.
  4. For returned goods, review the product history to determine if the product can be reused, reworked, or needs to be discarded based on its condition and the cause of the return.

5.3 Documentation and Record Keeping

  1. Document all returned goods, including the batch number, the quantity returned, the reason for return, and the action taken (rejection, reuse, or rework) in the Return Goods Log (Annexure-4).
  2. Ensure that all inspection results, corrective actions, and approvals are recorded in the Return Goods Evaluation Log (Annexure-5).
  3. Maintain records of the return authorization form, inspection results, and any communications regarding the return for traceability and future reference.

5.4 Action on Returned Goods

  1. If the returned goods are finished products and cannot be reworked or resold, they must be disposed of in accordance with regulatory guidelines for the disposal of pharmaceutical products.
  2. If the returned goods are raw materials, assess whether they can be returned to inventory for use in future production. Ensure that the material is properly requalified before it is reused.
  3. If the returned goods can be reworked, create a rework plan, including a description of the process, equipment, and personnel involved, and ensure that the rework process complies with GMP guidelines (Annexure-6).
  4. If returned goods are defective and cannot be reused or reworked, ensure that they are properly disposed of following the disposal guidelines and regulatory requirements.

5.5 Corrective Actions and Preventive Actions (CAPA)

  1. If returned goods are found to be defective, investigate the root cause of the issue and document the findings in the CAPA Log (Annexure-7).
  2. Implement corrective actions to resolve the root cause of the defect, such as process improvements, equipment maintenance, or staff training.
  3. Implement preventive actions to prevent the recurrence of similar issues with future production batches.

5.6 Disposal of Returned Goods

  1. For returned goods that cannot be reworked or reused, ensure proper disposal in accordance with environmental regulations and local disposal guidelines for pharmaceutical products.
  2. Document all disposal activities, including the reason for disposal, the method of disposal, and the date, in the Disposal Log (Annexure-8).

5.7 Compliance Monitoring

  1. Conduct periodic reviews of the return goods handling process to ensure compliance with regulatory requirements and internal SOPs.
  2. Track and review any trends or recurring issues with returned goods to identify areas for improvement in the manufacturing, packaging, or quality control processes.

6. Abbreviations

7. Documents

  1. Return Goods Log (Annexure-4)
  2. Return Goods Evaluation Log (Annexure-5)
  3. Rework Plan (Annexure-6)
  4. CAPA Log (Annexure-7)
  5. Disposal Log (Annexure-8)

8. References

9. SOP Version

Version: 2.0

10. Approval Section

Prepared By Checked By Approved By
Signature
Date
Name
Designation
Department

11. Annexures

Annexure-1: Return Goods Inspection Report

Material Name Batch Number Reason for Return Inspection Results Action Taken
Tablet A Batch-12345 Defective packaging No damage found Returned to inventory

Annexure-2: Return Authorization Form

Return ID Material Name Batch Number Reason for Return Return Date
RMA-12345 Tablet A Batch-12345 Customer complaint 01/03/2026

Annexure-3: Material Return Evaluation Log

Batch Number Material Name Evaluation Result Action Taken
Batch-12345 Tablet A Pass Reworked

Annexure-4: Return Goods Documentation Log

Return ID Batch Number Action Taken Return Date
RMA-12345 Batch-12345 Returned to inventory 01/03/2026

Annexure-5: Disposal Log

Return ID Material Name Disposal Date Disposal Method
RMA-12345 Tablet A 02/03/2026 Incineration

Annexure-6: CAPA Log

Action ID Action Description Responsible Person Completion Date
CAPA-001 Investigated customer complaints Jane Smith 01/05/2026

Revision History:

Revision Date Revision No. Revision Details Reason for Revision Approved By
01/01/2024 1.0 Initial Version New SOP Creation QA Head
01/02/2025 2.0 Updated return procedures Improved handling of returned materials QA Head
Exit mobile version