Skip to content
  • Clinical Studies
  • Schedule M
  • Stability Studies
  • Pharma GMP
  • Pharma Tips
  • Pharma Books
  • Pharma Validation
  • Pharma Regulatory

SOP Guide for Pharma

The Ultimate Resource for Pharmaceutical SOPs and Best Practices

  • Home
  • SOP Guidelines
    • SOP Development
    • SOP Training
    • SOP Compliance Monitoring
    • SOP Revision Processes
    • Pharmaceutical SOP templates
    • GMP documentation SOP
    • Data integrity SOP pharma
    • Manufacturing SOP pharmaceutical
    • FDA SOP guidance
    • eQMS SOP workflows
  • Job Safety Analysis (JSA)
    • Oral Dosage Forms (Tablets & Capsules)
    • Oral Liquid Dosage Forms (Syrups, Elixirs, Suspensions, Emulsions)
    • Powder and Granule Dosage Forms
    • Topical Dosage Forms (Creams, Ointments, Gels, Lotions, Pastes)
    • Transdermal Dosage Forms (Patches)
  • Standard Test Procedures (STP)
  • GMP Audit Findings
    • Non-Compliance
      • SOP Absence
      • Revision Control
      • Non-Adherence
      • Poor Writing
      • Training Failure
      • Data Integrity Gaps
      • Mismatch Between SOPs and Practice
      • Critical Operations
      • Regulatory Change
      • Emergency Changes
      • Third-Party SOPs
      • Inspection Readiness
      • Deviation Handling
      • CAPA Integration
      • Validation Alignment
      • System Integration
      • Uncontrolled Distribution
      • SOP Implementation Gaps
      • SOP Alignment with Validation
      • Change Control Linkage
  • Toggle search form

Sterile Injectable Manufacturing: SOP for Monitoring Temperature during Sterile Filling – V 2.0

Posted on By

Sterile Injectable Manufacturing: SOP for Monitoring Temperature during Sterile Filling – V 2.0

Standard Operating Procedure for Monitoring Temperature during Sterile Filling


Department Sterile Injectable Manufacturing
SOP No. SOP/SIM/071/2025
Supersedes SOP/SIM/071/2022
Page No. Page 1 of 12
Issue Date 18/06/2025
Effective Date 20/06/2025
Review Date 18/06/2026

1. Purpose

This SOP defines the procedure for real-time monitoring and control of temperature conditions during the sterile filling process to maintain product integrity and meet GMP compliance.

2. Scope

This SOP applies to all sterile filling activities conducted under laminar airflow conditions within aseptic manufacturing

areas for injectable products.

3. Responsibilities

  • Production Operator: Monitors and records temperature at defined intervals.
  • Engineering Personnel: Calibrates and maintains temperature monitoring instruments.
  • QA Officer: Verifies temperature records and ensures SOP adherence.
See also  Sterile Injectable Manufacturing: SOP for Visual Inspection of Injectable Products for Clarity - V 2.0

4. Accountability

The Head of Production is accountable for the implementation and compliance with this SOP.

5. Procedure

5.1 Preparation Before Filling

  1. Ensure all temperature monitoring devices (digital sensors, thermocouples, etc.) are calibrated and installed at strategic points in the filling line.
  2. Verify calibration certificates before initiating filling (Annexure-1: Calibration Verification Log).

5.2 Temperature Monitoring During Filling

  1. Monitor and record temperature every 30 minutes during the sterile filling activity.
  2. Ensure filling is conducted within validated temperature ranges (e.g., 18°C–25°C).
  3. Use automated systems with data logging where available; in absence, use manual temperature log sheets (Annexure-2).
  4. In case of deviation from the acceptable range, immediately:
    • Stop the filling operation.
    • Inform QA and Engineering.
    • Initiate deviation report and root cause analysis (Annexure-3).
See also  Sterile Injectable Manufacturing: SOP for Compatibility Studies of Container Closure Systems - V 2.0

5.3 Post-Operation Review

  1. QA shall review temperature logs post batch completion.
  2. Logs shall be archived as part of batch manufacturing records (minimum retention: 5 years).

6. Abbreviations

  • SOP: Standard Operating Procedure
  • QA: Quality Assurance
  • °C: Degrees Celsius

7. Documents

  1. Calibration Verification Log – Annexure-1
  2. Temperature Monitoring Log Sheet – Annexure-2
  3. Temperature Deviation Report – Annexure-3

8. References

  • WHO Technical Report Series 961, Annex 6
  • EU GMP Annex 1: Manufacture of Sterile Medicinal Products
  • ICH Q9: Quality Risk Management

9. SOP Version

Version: 2.0

10. Approval Section

Prepared By Checked By Approved By
Signature
Date
Name
Designation Manufacturing Executive QA Executive Head QA
Department Production Quality Assurance Quality Assurance
See also  Sterile Injectable Manufacturing: SOP for Reconciliation of Materials Used in Manufacturing - V 2.0

11. Annexures

Annexure-1: Calibration Verification Log

Device ID Location Calibration Due Verified By
TS-104 Filling Zone A 30/06/2025 Sunita Reddy

Annexure-2: Temperature Monitoring Log Sheet

Date Time Temperature (°C) Recorded By Remarks
18/06/2025 09:00 AM 22.3 Rajesh Kumar Within range

Annexure-3: Temperature Deviation Report

Date Deviation Observed Corrective Action Root Cause Reviewed By
18/06/2025 27.5°C Filling stopped, HVAC adjusted AHU malfunction Anita Desai

Revision History

Revision Date Revision No. Details Reason Approved By
01/01/2022 1.0 Initial Issue New SOP QA Head
18/06/2025 2.0 Updated temperature recording and annexures Periodic Review QA Head
Injectables V 2.0 Tags:Aseptic processing SOP, Aseptic technique in sterile manufacturing, Cleanroom SOP for injectables, SOP for ampoule sealing, SOP for autoclave sterilization, SOP for container closure integrity testing, SOP for environmental monitoring in aseptic area, SOP for gowning in cleanroom, SOP for in-process checks in sterile manufacturing, SOP for injectable formulation, SOP for lyophilizer operation, SOP for sterile filtration, SOP for sterilization validation, SOP for vial filling, SOP for visual inspection of injectables, Sterile area cleaning SOP, Sterile filling line SOP, Sterile injectable quality control SOP, Sterile injection SOP, Sterile manufacturing procedure

Post navigation

Previous Post: API Manufacturing: SOP for Segregation and Disposal of Hazardous Waste – V 2.0
Next Post: Gel Manufacturing: SOP for Sealing Gel Packaging to Prevent Contamination – V 2.0

Standard Operating Procedures V 1.0

  • Aerosols
  • Analytical Method Development
  • Bioequivalence Bioavailability Study
  • Capsule Formulation
  • Clinical Studies
  • Creams
  • Data Integrity
  • Dental Dosage Forms
  • Drug Discovery
  • Environment, Health and Safety
  • Formulation Development
  • Gels
  • Good Distribution Practice
  • Good Warehousing Practices
  • In-Process Control
  • Injectables
  • Liquid Orals
  • Liposome and Emulsion Formulations
  • Lotions
  • Lyophilized Products
  • Maintenance Dept.
  • Medical Devices
  • Metered-Dose Inhaler
  • Microbiology Testing
  • Nanoparticle Formulation
  • Nasal Spray Formulations
  • Nebulizers
  • Ocular (Eye) Dosage Forms
  • Ointments
  • Otic (Ear) Dosage Forms
  • Pharmacovigilance
  • Powder & Granules
  • Purchase Departments
  • Quality Assurance
  • Quality Control
  • Raw Material Stores
  • Regulatory Affairs
  • Tablet Manufacturing
  • Rectal Dosage Forms
  • Transdermal Patches
  • Vaginal Dosage Forms
  • Validations and Qualifications

Read SOPs in your Language:

 - 
Bengali
 - 
bn
English
 - 
en
Gujarati
 - 
gu
Hindi
 - 
hi
Malayalam
 - 
ml
Marathi
 - 
mr
Punjabi
 - 
pa
Tamil
 - 
ta
Telugu
 - 
te

NEW! Revised SOPs – V 2.0

  • Aerosols V 2.0
  • Analytical Method Development V 2.0
  • API Manufacturing V 2.0
  • BA-BE Studies V 2.0
  • Biosimilars V 2.0
  • Capsules V 2.0
  • Creams V 2.0
  • Elixers V 2.0
  • Gels V 2.0
  • Injectables V 2.0
  • Ointments V 2.0
  • Raw Material Warehouse V 2.0
  • Tablet Manufacturing V2.0

New Publication: A must for All.

Copyright © 2026 SOP Guide for Pharma.

Powered by PressBook WordPress theme

Go to mobile version