Sterile Injectable Manufacturing: SOP for Investigations of Complaints Related to Injectable Products – V 2.0
Standard Operating Procedure for Investigations of Complaints Related to Injectable Products
| Department |
Sterile Injectable Manufacturing |
| SOP No. |
SOP/SIM/088/2025 |
| Supersedes |
SOP/SIM/088/2022 |
| Page No. |
Page 1 of 14 |
| Issue Date |
18/06/2025 |
| Effective Date |
20/06/2025 |
| Review Date |
18/06/2026 |
1. Purpose
To define a standard procedure for managing, investigating, and closing complaints related to sterile injectable products, ensuring product quality, patient safety, and regulatory compliance.
2. Scope
This SOP applies to all complaints received internally or externally that concern sterile
injectable products manufactured at the facility, including product defects, adverse reactions, and quality-related issues.
3. Responsibilities
- QA Head: Overall responsibility for complaint handling and closure.
- Complaint Handling Officer: Receives, records, investigates, and coordinates all activities related to complaint investigations.
- Production Head: Provides relevant manufacturing information for investigation.
- QC Manager: Conducts sample analysis if required during investigation.
4. Accountability
The Quality Assurance Department is accountable for ensuring that all product complaints are handled, investigated, documented, and closed in a timely and compliant manner.
5. Procedure
5.1 Complaint Receipt and Recording
- Complaints may be received via telephone, email, written letters, regulatory bodies, or field representatives.
- Immediately log the complaint in the Product Complaint Register (Annexure-1).
- Assign a unique complaint ID in the format: COMP/YY/NNN.
- Acknowledge receipt to the complainant within 2 working days.
5.2 Preliminary Assessment
- Review complaint description, product details, and batch number.
- Check if similar complaints have been reported earlier.
- Evaluate if the complaint is critical (e.g., sterility failure, adverse event, contamination).
- Inform QA Head immediately if criticality is high.
5.3 Investigation and Root Cause Analysis
- Form a cross-functional investigation team (QA, QC, Production, Regulatory as needed).
- Review:
- Batch Manufacturing Record (BMR)
- Packaging records
- In-process control results
- Environmental monitoring data
- If sample is returned, send to QC for analysis and retain records in Annexure-2: Sample Analysis Log.
- Document findings in Annexure-3: Complaint Investigation Report.
5.4 Corrective and Preventive Actions (CAPA)
- Based on investigation outcome, initiate appropriate CAPA.
- Assign CAPA responsibilities with target dates.
- Track CAPA completion and effectiveness verification.
5.5 Closure and Documentation
- QA Head reviews investigation and CAPA completion.
- Approve final closure with documented conclusion and corrective measures implemented.
- Update Complaint Register with closure status and date.
- Maintain complaint records for a minimum of 5 years.
6. Abbreviations
- SOP: Standard Operating Procedure
- QA: Quality Assurance
- QC: Quality Control
- CAPA: Corrective and Preventive Action
- BMR: Batch Manufacturing Record
7. Documents
- Product Complaint Register – Annexure-1
- Sample Analysis Log – Annexure-2
- Complaint Investigation Report – Annexure-3
8. References
- ICH Q10 – Pharmaceutical Quality System
- 21 CFR 211.198 – Complaint Files
- WHO TRS 986 Annex 2 – Quality Risk Management
9. SOP Version
Version: 2.0
10. Approval Section
|
Prepared By |
Checked By |
Approved By |
| Signature |
|
|
|
| Date |
|
|
|
| Name |
|
|
|
| Designation |
Manufacturing Executive |
QA Executive |
Head QA |
| Department |
Production |
Quality Assurance |
Quality Assurance |
11. Annexures
Annexure-1: Product Complaint Register
| Complaint ID |
Date |
Product |
Batch No. |
Nature of Complaint |
Status |
| COMP/25/001 |
10/06/2025 |
Inj. Ceftriaxone 1g |
CTJ25001 |
Particulate matter |
Closed |
Annexure-2: Sample Analysis Log
| Complaint ID |
Sample Received |
Test Performed |
Result |
Analyst |
| COMP/25/001 |
Yes |
Visual Inspection |
Particulate Confirmed |
Priya Nair |
Annexure-3: Complaint Investigation Report
| Complaint ID |
Investigation Summary |
Root Cause |
CAPA Taken |
Closure Date |
| COMP/25/001 |
Packaging fiber found inside vial |
Operator error during capping |
Retrained staff, added inspection step |
15/06/2025 |
Revision History
| Revision Date |
Revision No. |
Details |
Reason |
Approved By |
| 01/07/2022 |
1.0 |
Initial Release |
New SOP |
QA Head |
| 18/06/2025 |
2.0 |
Added CAPA traceability and sample log |
Review Update |