1. Purpose

This SOP describes the standard procedure for intermediate storage of bulk injectable solutions prior to the filling stage, ensuring product integrity, traceability, and compliance with GMP and WHO standards.

2. Scope

This SOP applies to all batches of

bulk injectable products held temporarily during sterile manufacturing within designated intermediate storage tanks or vessels in the sterile area.

3. Responsibilities

  • Manufacturing Operator: Transfers and stores bulk solutions per batch record and SOP instructions.
  • Supervisor: Monitors and documents storage conditions and timelines.
  • QA Officer: Verifies adherence to storage specifications and performs line clearance.
  • Engineering: Ensures calibration and maintenance of storage vessels and monitoring equipment.

4. Accountability

The Head of Manufacturing is accountable for ensuring that all bulk injectable materials are stored under validated conditions and within defined hold times, as per the product-specific requirements.

5. Procedure

5.1 Preparation for Storage

  1. Ensure the bulk solution transfer line is sterilized and integrity-verified.
  2. Verify the receiving vessel (e.g., intermediate storage tank) has been cleaned and sterilized per SOP/SIM/032/2025.
  3. Affix status label on the vessel indicating “Ready for Use.”

5.2 Transfer and Storage

  1. Transfer bulk injectable solution under Grade A/B environment using aseptic technique.
  2. Document the start and end time of transfer in the Bulk Transfer Log (Annexure-1).
  3. Ensure storage temperature is maintained between 20°C to 25°C (unless product-specific range is defined).
  4. Seal all ports and cover with sterile caps post-transfer.

5.3 Storage Monitoring

  1. Monitor and record the vessel temperature every 30 minutes during hold time (Annexure-2).
  2. QA shall review temperature logs for compliance during batch record review.
  3. If any deviation is observed in temperature or seal integrity, initiate deviation report immediately.

5.4 Time Limit for Hold

  1. The maximum hold time must not exceed the time established in the process validation report or product master formula (e.g., 48 hours).
  2. Document start and expiry of hold time on the Batch Manufacturing Record (BMR).
  3. QA must authorize further processing if time limits are about to lapse.

5.5 Post-Storage Processing

  1. Verify all conditions (temp, duration, microbial limits) before proceeding to the filling stage.
  2. Use dedicated transfer lines to move the solution to the filling machine under aseptic conditions.
  3. Clean and sterilize intermediate vessels after each batch cycle and document in the Equipment Cleaning Log.

6. Abbreviations

  • SOP: Standard Operating Procedure
  • BMR: Batch Manufacturing Record
  • QA: Quality Assurance
  • GMP: Good Manufacturing Practice
  • WHO: World Health Organization

7. Documents

  1. Bulk Transfer Log – Annexure-1
  2. Temperature Monitoring Log – Annexure-2
  3. Storage Hold Time Verification Sheet – Annexure-3

8. References

  • WHO TRS 961: GMP for Sterile Pharmaceutical Products
  • EU GMP Annex 1
  • ICH Q7: Good Manufacturing Practice Guidance

9. SOP Version

Version: 2.0

10. Approval Section

Prepared By Checked By Approved By
Signature
Date
Name
Designation Manufacturing Executive QA Executive Head QA
Department Production Quality Assurance Quality Assurance

11. Annexures

Annexure-1: Bulk Transfer Log

Date Batch No. Start Time End Time Transferred By Verified By (QA)
18/06/2025 IV-4521 10:00 10:35 Manoj Kumar Neha Shah

Annexure-2: Temperature Monitoring Log

Date Time Temperature (°C) Checked By Remarks
18/06/2025 10:30 22.1 Anjali Sinha Within Range
18/06/2025 11:00 21.9 Anjali Sinha Within Range

Annexure-3: Storage Hold Time Verification Sheet

Batch No. Hold Start Time Hold End Time Duration (Hours) Verified By
IV-4521 10:35 22:35 12 Sunita Reddy

Revision History

Revision Date Revision No. Details Reason Approved By
10/02/2022 1.0 Initial release New SOP QA Head
18/06/2025 2.0 Added hold time verification table and updated monitoring log Annual Review QA Head