Standard Operating Procedure for Filtration Process in Sterile Injections
| Department | Sterile Injectable Manufacturing |
|---|---|
| SOP No. | SOP/SIM/027/2025 |
| Supersedes | SOP/SIM/027/2022 |
| Page No. | Page 1 of 15 |
| Issue Date | 18/06/2025 |
| Effective Date | 20/06/2025 |
| Review Date | 18/06/2026 |
1. Purpose
This SOP describes the procedure for performing sterile filtration during the manufacturing of injectable drug products. It ensures removal of bioburden and particulates prior to aseptic filling in compliance with GMP and regulatory requirements.
2. Scope
This procedure is applicable to all sterile injectable formulations requiring sterile filtration using 0.22 µm or equivalent validated membrane filters in the Sterile Injectable Manufacturing facility.
3. Responsibilities
- Manufacturing Operator: Executes filtration and records data as per BMR.
- Supervisor: Verifies setup, parameters, and signs off on in-process checks.
- QA Executive: Provides line clearance, performs periodic checks, and ensures compliance with aseptic practices.
- Engineering Team: Assists in setup, calibration, and maintenance of filtration equipment.
4. Accountability
Head – Production is accountable for execution. Head – QA is accountable for final approval and compliance oversight.
5. Procedure
5.1 Pre-Filtration Preparation
- Verify cleaning and sterilization status of filtration assembly and bulk solution tank.
- Check batch-specific BMR for filter type, number, and validation status.
- Ensure environmental parameters in filtration area meet Grade B or better classification.
5.2 Filter Assembly Setup
- Use sterile membrane filters (typically 0.22 µm) validated for the product.
- Attach filters aseptically under LAF hood using pre-sterilized tubing and clamps.
- Ensure all connections are tight and leak-free.
5.3 Filtration Execution
- Transfer the prepared bulk solution to the sterile filtration vessel.
- Initiate filtration by gravity or pressure-driven setup as defined in the BMR.
- Monitor differential pressure across the filter and maintain within defined limits (e.g., <2.5 bar).
- Ensure continuous flow without interruption or contamination risk.
5.4 Filter Integrity Testing
- Perform pre-use bubble point test or diffusive flow test on sterilized filters using validated equipment.
- Document filter serial number, lot, and test result in Annexure-1.
- Repeat integrity test post-filtration and ensure pass status.
5.5 Post-Filtration Activities
- Label the sterile filtered solution container as “Sterile Bulk”.
- Transfer to aseptic filling line under QA supervision.
- Clean filtration setup as per cleaning SOP and record in Annexure-2.
6. Abbreviations
- SOP: Standard Operating Procedure
- BMR: Batch Manufacturing Record
- LAF: Laminar Air Flow
- QA: Quality Assurance
- µm: Micron
7. Documents
- Filter Integrity Record – Annexure-1
- Filtration Setup and Cleaning Record – Annexure-2
- Environmental Monitoring Sheet – Annexure-3
8. References
- WHO TRS 961, Annex 6 – GMP for Sterile Pharmaceuticals
- EU GMP Annex 1
- ICH Q8 – Pharmaceutical Development
See also Sterile Injectable Manufacturing: SOP for Osmolality Testing of Injectable Products - V 2.0
9. SOP Version
Version: 2.0
10. Approval Section
| Prepared By | Checked By | Approved By | |
|---|---|---|---|
| Signature | |||
| Date | |||
| Name | |||
| Designation | Manufacturing Executive | QA Executive | Head QA |
| Department | Production | Quality Assurance | Quality Assurance |
11. Annexures
Annexure-1: Filter Integrity Record
| Filter ID | Lot No. | Pre-Test Result | Post-Test Result | Status | Checked By |
|---|---|---|---|---|---|
| FLT-112 | F01234 | Pass | Pass | Accepted | Rahul Sharma |
Annexure-2: Filtration Setup and Cleaning Record
| Date | Batch No. | Setup Verified By | Cleaning Done By | Remarks |
|---|---|---|---|---|
| 18/06/2025 | IVF2025-07 | Priya Verma | Kamal Yadav | Setup completed and cleaned |
Annexure-3: Environmental Monitoring Sheet
| Area | Temperature (°C) | RH (%) | Differential Pressure (Pa) | Monitored By |
|---|---|---|---|---|
| Filtration Room | 22 | 45 | 15 | Sunita Iyer |
Revision History
| Revision Date | Revision No. | Details | Reason | Approved By |
|---|---|---|---|---|
| 15/03/2022 | 1.0 | Initial Release | Baseline SOP | QA Head |
| 18/06/2025 | 2.0 | Added new annexures and clarified filter validation steps | Annual Review | QA Head |