Sterile Injectable Manufacturing: SOP for Ensuring Tamper Evidence in Injectable Packaging – V 2.0
Standard Operating Procedure for Ensuring Tamper Evidence in Injectable Packaging
| Department |
Sterile Injectable Manufacturing |
| SOP No. |
SOP/SIM/097/2025 |
| Supersedes |
SOP/SIM/097/2022 |
| Page No. |
Page 1 of 11 |
| Issue Date |
18/06/2025 |
| Effective Date |
20/06/2025 |
| Review Date |
18/06/2026 |
1. Purpose
To define the procedure for implementing and verifying tamper-evident features in the packaging of sterile injectable products in order to maintain product integrity and meet regulatory requirements.
2. Scope
This SOP applies to all sterile injectable products manufactured and packaged at the facility,
including vials, ampoules, prefilled syringes, and other sterile dosage forms requiring tamper-evident seals or indicators.
3. Responsibilities
- Packaging Operator: Ensures tamper-evident materials are applied correctly during packaging operations.
- IPQA Officer: Monitors and verifies the integrity of tamper-evident features on each batch.
- Quality Control: Inspects random samples for seal integrity and adherence to specifications.
4. Accountability
The Packaging Manager is accountable for ensuring all injectable products are packed with appropriate tamper-evident mechanisms as per regulatory expectations.
5. Procedure
5.1 Types of Tamper-Evident Features
- Use of flip-off seals for vials with distinct color-coding for each product strength.
- Aluminum crimping with breakable evidence for ampoules.
- Pre-attached plastic break-away caps for prefilled syringes.
- Security holograms or tamper-indicating stickers on secondary cartons.
5.2 Material Inspection
- Inspect tamper-evident components upon receipt for visual defects, labeling accuracy, and quantity.
- Ensure all incoming packaging components bear batch numbers and are stored separately as per SOP/SIM/096/2025.
5.3 Application in Primary Packaging
- During the filling and sealing process, ensure that:
- Flip-off seals are applied uniformly and pressed firmly.
- Breakable ampoule necks are flame-sealed accurately.
- Syringes are capped with pre-tensioned tamper-proof caps.
- Packaging line in-process checks must verify 100% application of seals and alignment.
5.4 Secondary Packaging Verification
- Verify holograms or stickers are positioned as per packaging artwork on each carton.
- IPQA must inspect random samples from every batch to confirm seal integrity and tamper-evidence visibility.
5.5 Defect Management
- Any product with misaligned, damaged, or missing tamper seals shall be rejected and recorded in the deviation log (Annexure-2).
- Defective materials shall be stored in a designated area and disposed of as per SOP/QC/REJ/011.
5.6 Training and Awareness
- All personnel involved in packaging shall be trained annually on tamper-evident features and visual inspection techniques.
- Training records to be maintained (Annexure-3).
6. Abbreviations
- SOP: Standard Operating Procedure
- QA: Quality Assurance
- IPQA: In-Process Quality Assurance
- QC: Quality Control
7. Documents
- Tamper-Evident Component Receipt Log – Annexure-1
- Deviation Log – Annexure-2
- Training Record – Annexure-3
8. References
- 21 CFR Part 211.132 – Tamper-evident packaging requirements for over-the-counter (OTC) human drug products
- EU GMP Guidelines – Annex 16: Certification by a Qualified Person
- WHO TRS 986 Annex 2 – GMP Guidelines for Pharmaceutical Products
9. SOP Version
Version: 2.0
10. Approval Section
|
Prepared By |
Checked By |
Approved By |
| Signature |
|
|
|
| Date |
|
|
|
| Name |
|
|
|
| Designation |
Manufacturing Executive |
QA Executive |
Head QA |
| Department |
Production |
Quality Assurance |
Quality Assurance |
11. Annexures
Annexure-1: Tamper-Evident Component Receipt Log
| Date |
Material |
Batch No. |
Qty |
Received By |
| 15/06/2025 |
Flip-off seals (Red) |
FOS-1023 |
20,000 |
Rajesh Kumar |
Annexure-2: Deviation Log
| Date |
Batch No. |
Description of Deviation |
Corrective Action |
Approved By |
| 16/06/2025 |
INJ-097 |
10 cartons missing hologram |
Line rechecked and replaced |
Sunita Reddy |
Annexure-3: Training Record
| Employee Name |
Department |
Training Date |
Trainer |
Status |
| Ajay Verma |
Packaging |
10/06/2025 |
QA Officer |
Completed |
Revision History
| Revision Date |
Revision No. |
Details |
Reason |
Approved By |
| 01/04/2022 |
1.0 |
Initial version |
New SOP |
Head QA |
| 18/06/2025 |
2.0 |
Included secondary packaging hologram inspection |
Periodic review |