Skip to content
  • Clinical Studies
  • Schedule M
  • Stability Studies
  • Pharma GMP
  • Pharma Tips
  • Pharma Books
  • Pharma Validation
  • Pharma Regulatory

SOP Guide for Pharma

The Ultimate Resource for Pharmaceutical SOPs and Best Practices

  • Home
  • SOP Guidelines
    • SOP Development
    • SOP Training
    • SOP Compliance Monitoring
    • SOP Revision Processes
    • Pharmaceutical SOP templates
    • GMP documentation SOP
    • Data integrity SOP pharma
    • Manufacturing SOP pharmaceutical
    • FDA SOP guidance
    • eQMS SOP workflows
  • Job Safety Analysis (JSA)
    • Oral Dosage Forms (Tablets & Capsules)
    • Oral Liquid Dosage Forms (Syrups, Elixirs, Suspensions, Emulsions)
    • Powder and Granule Dosage Forms
    • Topical Dosage Forms (Creams, Ointments, Gels, Lotions, Pastes)
    • Transdermal Dosage Forms (Patches)
  • Standard Test Procedures (STP)
  • GMP Audit Findings
    • Non-Compliance
      • SOP Absence
      • Revision Control
      • Non-Adherence
      • Poor Writing
      • Training Failure
      • Data Integrity Gaps
      • Mismatch Between SOPs and Practice
      • Critical Operations
      • Regulatory Change
      • Emergency Changes
      • Third-Party SOPs
      • Inspection Readiness
      • Deviation Handling
      • CAPA Integration
      • Validation Alignment
      • System Integration
      • Uncontrolled Distribution
      • SOP Implementation Gaps
      • SOP Alignment with Validation
      • Change Control Linkage
  • Toggle search form

Sterile Injectable Manufacturing: SOP for Ensuring No Residue Post-Cleaning of Machines – V 2.0

Posted on By

Sterile Injectable Manufacturing: SOP for Ensuring No Residue Post-Cleaning of Machines – V 2.0

Standard Operating Procedure for Ensuring No Residue Post-Cleaning of Machines


Department Sterile Injectable Manufacturing
SOP No. SOP/SIM/158/2025
Supersedes SOP/SIM/158/2022
Page No. Page 1 of 14
Issue Date 24/06/2025
Effective Date 26/06/2025
Review Date 24/06/2026

1. Purpose

This SOP describes the process for verifying that no cleaning residues remain on sterile injectable manufacturing equipment post-cleaning. The procedure ensures equipment surfaces are free from contaminants, chemicals, and residues before reuse, in compliance with cGMP and regulatory standards.

2.

Scope

This SOP is applicable to all equipment used in sterile injectable manufacturing including solution preparation tanks, mixing vessels, filters, lyophilizers, and filling machines that undergo cleaning prior to reuse.

3. Responsibilities

  • Production Operator: Executes cleaning procedures and performs visual inspection.
  • QA Executive: Conducts swab sampling and verifies visual inspection.
  • QC Analyst: Performs analytical tests for residue detection such as TOC, conductivity, and specific chemical analysis.
  • Engineering Technician: Assists in cleaning validation equipment and calibration.

4. Accountability

The Head of Quality Assurance is accountable for ensuring this SOP is followed and that all cleaning verifications are conducted before equipment reuse.

5. Procedure

5.1 Visual Inspection

  1. Post-cleaning, the production operator must perform a thorough visual inspection under adequate lighting.
  2. Check all internal surfaces, joints, nozzles, and ports for any residue, discoloration, or foreign matter.
  3. Document findings in the Equipment Cleaning Checklist (Annexure-1).
  4. QA to perform a second-level visual check to verify cleanliness.

5.2 Swab Sampling

  1. Identify sampling points based on worst-case locations (e.g., dead legs, crevices).
  2. Use pre-validated sterile swabs moistened with WFI to swab an area of 25 cm².
  3. Place swabs in sterile containers, label with equipment ID and sampling point.
  4. Submit to QC laboratory for chemical and microbial testing.

5.3 Rinse Sampling

  1. If swab sampling is not feasible, collect rinse samples from final WFI rinse after cleaning.
  2. Collect at least 100 mL in sterile containers and label appropriately.
  3. Submit for TOC, conductivity, and chemical residue analysis.

5.4 Analytical Testing

  • Test samples against predefined acceptance criteria:
    • TOC: < 500 ppb
    • Conductivity: < 1.3 µS/cm
    • API-specific limits: As per cleaning validation protocol
    • Microbial limits: < 10 CFU/100 cm²
  • Document test results in the Residue Testing Log (Annexure-2).

5.5 Verification and Documentation

  1. QA must review all test reports and visual inspection records.
  2. If results comply with acceptance criteria, QA will sign the Equipment Release Form (Annexure-3).
  3. Equipment shall be labeled as “Cleaned and Ready for Use.”
  4. All records must be archived in the cleaning validation file for traceability.

5.6 Deviation Handling

  1. If residue is found above limits:
    • Repeat cleaning process immediately.
    • Investigate root cause using deviation form.
    • Record corrective and preventive actions.

6. Abbreviations

  • SOP: Standard Operating Procedure
  • QA: Quality Assurance
  • QC: Quality Control
  • WFI: Water for Injection
  • TOC: Total Organic Carbon
  • CFU: Colony Forming Units
  • ID: Identification

7. Documents

  1. Annexure-1: Equipment Cleaning Checklist
  2. Annexure-2: Residue Testing Log
  3. Annexure-3: Equipment Release Form

8. References

  • ICH Q7 – Good Manufacturing Practice for Active Pharmaceutical Ingredients
  • FDA Guidance on Cleaning Validation
  • WHO Technical Report Series No. 937

9. SOP Version

Version: 2.0

10. Approval Section

Prepared By Checked By Approved By
Signature
Date
Name
Designation Manufacturing Executive QA Executive Head QA
Department Production Quality Assurance Quality Assurance

11. Annexures

Annexure-1: Equipment Cleaning Checklist

Date Equipment ID Visual Inspection Status Operator QA Reviewer
23/06/2025 MLT-05 Clean Ravi Patel Sunita Reddy

Annexure-2: Residue Testing Log

Sample ID TOC (ppb) Conductivity (µS/cm) CFU Status Analyst
MLT05-R1 92 1.1 1 Pass Vinay Kumar

Annexure-3: Equipment Release Form

Equipment ID Cleaning Status QA Approval Date Remarks
MLT-05 Approved Sunita Reddy 23/06/2025 Ready for use

Revision History:

Revision Date Revision No. Details Reason Approved By
12/03/2022 1.0 Initial Release New SOP QA Head
24/06/2025 2.0 Updated criteria and added Annexures Annual Review QA Head
See also  Packaging: SOP for Final Labeling and Batch Coding of Injectable Vials - V 2.0
Injectables V 2.0 Tags:Aseptic processing SOP, Aseptic technique in sterile manufacturing, Cleanroom SOP for injectables, SOP for ampoule sealing, SOP for autoclave sterilization, SOP for container closure integrity testing, SOP for environmental monitoring in aseptic area, SOP for gowning in cleanroom, SOP for in-process checks in sterile manufacturing, SOP for injectable formulation, SOP for lyophilizer operation, SOP for sterile filtration, SOP for sterilization validation, SOP for vial filling, SOP for visual inspection of injectables, Sterile area cleaning SOP, Sterile filling line SOP, Sterile injectable quality control SOP, Sterile injection SOP, Sterile manufacturing procedure

Post navigation

Previous Post: Analytical Method Development: SOP for HPLC Method for Residual API on Equipment – V 2.0
Next Post: Understanding Read-and-Understand Training vs Practical Demonstration

Standard Operating Procedures V 1.0

  • Aerosols
  • Analytical Method Development
  • Bioequivalence Bioavailability Study
  • Capsule Formulation
  • Clinical Studies
  • Creams
  • Data Integrity
  • Dental Dosage Forms
  • Drug Discovery
  • Environment, Health and Safety
  • Formulation Development
  • Gels
  • Good Distribution Practice
  • Good Warehousing Practices
  • In-Process Control
  • Injectables
  • Liquid Orals
  • Liposome and Emulsion Formulations
  • Lotions
  • Lyophilized Products
  • Maintenance Dept.
  • Medical Devices
  • Metered-Dose Inhaler
  • Microbiology Testing
  • Nanoparticle Formulation
  • Nasal Spray Formulations
  • Nebulizers
  • Ocular (Eye) Dosage Forms
  • Ointments
  • Otic (Ear) Dosage Forms
  • Pharmacovigilance
  • Powder & Granules
  • Purchase Departments
  • Quality Assurance
  • Quality Control
  • Raw Material Stores
  • Regulatory Affairs
  • Tablet Manufacturing
  • Rectal Dosage Forms
  • Transdermal Patches
  • Vaginal Dosage Forms
  • Validations and Qualifications

Read SOPs in your Language:

 - 
Bengali
 - 
bn
English
 - 
en
Gujarati
 - 
gu
Hindi
 - 
hi
Malayalam
 - 
ml
Marathi
 - 
mr
Punjabi
 - 
pa
Tamil
 - 
ta
Telugu
 - 
te

NEW! Revised SOPs – V 2.0

  • Aerosols V 2.0
  • Analytical Method Development V 2.0
  • API Manufacturing V 2.0
  • BA-BE Studies V 2.0
  • Biosimilars V 2.0
  • Capsules V 2.0
  • Creams V 2.0
  • Elixers V 2.0
  • Gels V 2.0
  • Injectables V 2.0
  • Ointments V 2.0
  • Raw Material Warehouse V 2.0
  • Tablet Manufacturing V2.0

New Publication: A must for All.

Copyright © 2025 SOP Guide for Pharma.

Powered by PressBook WordPress theme