SOP Guide for Pharma

Sterile Injectable Manufacturing: SOP for Cleaning of Solution Preparation Vessels – V 2.0

Sterile Injectable Manufacturing: SOP for Cleaning of Solution Preparation Vessels – V 2.0

Standard Operating Procedure for Cleaning of Solution Preparation Vessels


Department Sterile Injectable Manufacturing
SOP No. SOP/SIM/058/2025
Supersedes SOP/SIM/058/2022
Page No. Page 1 of 12
Issue Date 18/06/2025
Effective Date 20/06/2025
Review Date 18/06/2026

1. Purpose

To describe the standardized procedure for cleaning solution preparation vessels used in sterile injectable manufacturing to ensure removal of product residues and microbial contaminants, thereby maintaining aseptic conditions in compliance with GMP requirements.

2. Scope

This SOP applies to all stainless-steel and glass-lined vessels used for

solution preparation in the sterile manufacturing department.

3. Responsibilities

  • Production Officer: Executes the cleaning operation as per defined protocol.
  • Engineering Officer: Ensures water supply and maintenance of CIP systems.
  • Quality Assurance (QA): Verifies cleanliness and signs off cleaning records.

4. Accountability

The Head of Production is accountable for ensuring proper cleaning and documentation of solution preparation vessels before and after each batch process.

5. Procedure

5.1 Pre-Cleaning Checks

  1. Ensure vessel is disconnected from electrical supply and process lines.
  2. Affix “Under Cleaning” status label on the equipment.
  3. Ensure all used materials are removed from the vessel area.

5.2 Cleaning Steps

  1. Manual Cleaning:
    • Rinse the vessel with purified water to remove gross residues.
    • Scrub internal surfaces using a nylon brush with 2% non-ionic detergent solution.
    • Pay special attention to impeller blades, baffles, and corners.
    • Rinse thoroughly with purified water until no foam remains.
  2. Automated CIP (if applicable):
    • Initiate CIP cycle as per equipment SOP with preset water, detergent, and rinse cycles.
    • Ensure all drain valves are functioning properly.
  3. Final Rinse:
    • Perform final rinse with Water for Injection (WFI).
    • Collect rinse water in clean sampling container for pH and TOC testing (if applicable).
  4. Dry the vessel using clean lint-free wipes and compressed filtered air.

5.3 Post-Cleaning Inspection

  1. Inspect vessel surfaces for cleanliness, absence of residues, and stains.
  2. QA to perform visual inspection and approve the cleaning.
  3. Log cleaning details in Cleaning Record (Annexure-1).

5.4 Frequency

  • After each batch and product changeover.
  • At least once every 7 days during idle time (if not used).

5.5 Special Considerations

  • Use dedicated brushes and cleaning tools for each vessel size and type.
  • Record any anomalies or deviations encountered during cleaning.

6. Abbreviations

  • SOP: Standard Operating Procedure
  • CIP: Clean-in-Place
  • WFI: Water for Injection
  • QA: Quality Assurance
  • TOC: Total Organic Carbon

7. Documents

  1. Cleaning Record – Annexure-1
  2. Post-Cleaning Inspection Checklist – Annexure-2
  3. pH and TOC Test Report – Annexure-3

8. References

  • ICH Q7: Good Manufacturing Practice for Active Pharmaceutical Ingredients
  • WHO TRS No. 961 Annex 6: GMP for Sterile Products
  • 21 CFR Part 211 – cGMP for Finished Pharmaceuticals

9. SOP Version

Version: 2.0

10. Approval Section

Prepared By Checked By Approved By
Signature
Date
Name
Designation Manufacturing Executive QA Executive Head QA
Department Production Quality Assurance Quality Assurance

11. Annexures

Annexure-1: Cleaning Record

Date Vessel ID Product Cleaned By Verified By
17/06/2025 SPV-001 Paracetamol Injection Rajesh Kumar Anita Sharma

Annexure-2: Post-Cleaning Inspection Checklist

Parameter Checked Remarks QA Signature
Residue-free interior Yes Clean Sunita Reddy
No stains or deposits Yes Accepted Sunita Reddy

Annexure-3: pH and TOC Test Report

Sample Date pH TOC (ppb) Tested By Remarks
17/06/2025 6.8 180 Vinay Pawar Within limits

Revision History

Revision Date Revision No. Details Reason Approved By
01/01/2022 1.0 Initial Issue New SOP QA Head
18/06/2025 2.0 Updated cleaning frequency and added TOC test Annual Review QA Head
Exit mobile version