Skip to content
  • Clinical Studies
  • Schedule M
  • Stability Studies
  • Pharma GMP
  • Pharma Tips
  • Pharma Books
  • Pharma Validation
  • Pharma Regulatory

SOP Guide for Pharma

The Ultimate Resource for Pharmaceutical SOPs and Best Practices

  • Home
  • Job Safety Analysis (JSA)
    • Oral Dosage Forms (Tablets & Capsules)
    • Oral Liquid Dosage Forms (Syrups, Elixirs, Suspensions, Emulsions)
    • Powder and Granule Dosage Forms
    • Topical Dosage Forms (Creams, Ointments, Gels, Lotions, Pastes)
    • Transdermal Dosage Forms (Patches)
  • Standard Test Procedures (STP)
  • SOP – Blog Post
  • Toggle search form

SOP for Use of Peristaltic Pumps in Formulation Processes

Posted on By




SOP for Use of Peristaltic Pumps in Formulation Processes



Standard Operating Procedure for Use of Peristaltic Pumps in Formulation Processes

1) Purpose

This SOP describes the proper use and operation of peristaltic pumps in pharmaceutical formulation processes, including dispensing liquid ingredients and transferring formulations in a controlled manner.

2) Scope

This SOP applies to all personnel involved in the operation and maintenance of peristaltic pumps at [Company Name].

3) Responsibilities

  • Operators: Responsible for setting up, operating, and cleaning the peristaltic pumps according to the process requirements.
  • Quality Assurance (QA): Ensures that the flow rates and volumes meet product specifications.
  • Maintenance Team: Responsible for the maintenance and calibration of the peristaltic pumps to ensure they operate within set parameters.

4) Procedure

4.1 Pre-Operation Setup

4.1.1 Equipment Inspection

  • Inspect the peristaltic pump for cleanliness, and ensure it is free from damage. Check that the tubing is properly installed and that there are no cracks or leaks in the tubing system.
  • Verify that the pump control panel and speed settings are functional. Document the inspection results in the equipment log.
See also  SOP for Implementing Corrective and Preventive Actions (CAPA)

4.1.2 Setting Up the Peristaltic Pump

  • Install the correct tubing size based on the
flow rate required for the formulation process. Ensure that the tubing is securely attached to the pump head and the formulation containers.
  • Set the desired flow rate, volume, and pumping time according to the Batch Manufacturing Record (BMR). Record the setup parameters in the BMR.
  • 4.2 Operation of the Peristaltic Pump

    4.2.1 Pumping Procedure

    • Start the peristaltic pump and monitor the flow rate and volume being transferred. Ensure that the flow is smooth and consistent, without any air bubbles or flow interruptions.
    • Perform in-process checks to ensure the volume being dispensed matches the formulation specifications. Record the results in the BMR.

    4.2.2 In-Process Adjustments

    • If necessary, adjust the flow rate or volume to maintain consistency in the formulation process. Document any changes in the BMR.

    4.3 Post-Operation Activities

    4.3.1 Cleaning and Shutdown

    • After completing the formulation process, turn off the peristaltic pump and disconnect the tubing. Disassemble any removable parts and clean them thoroughly using an approved cleaning agent.
    • Rinse the tubing and pump components with sterile water and allow them to dry. Document the cleaning process in the cleaning log.

    4.3.2 Final Documentation

    • Ensure all pumping parameters, in-process checks, and cleaning activities are recorded in the Batch Manufacturing Record (BMR) and equipment log. Submit all documents to QA for approval.

    4.4 Maintenance and Calibration

    4.4.1 Routine Maintenance

    • Inspect the peristaltic pump tubing, rollers, and motor weekly for wear and tear. Replace any worn-out components and document the maintenance activities in the maintenance log.

    4.4.2 Annual Calibration

    • Calibrate the flow rate control system annually to ensure accurate flow rates and volumes. Document the calibration results in the calibration log and submit for QA approval.

    5) Abbreviations, if any

    • BMR: Batch Manufacturing Record
    • QA: Quality Assurance

    6) Documents, if any

    • Batch Manufacturing Record (BMR)
    • Equipment Log
    • Cleaning Log
    • Maintenance Log
    • Calibration Log

    7) References, if any

    • Manufacturer’s equipment manual
    • Internal SOP for cleaning and maintenance

    8) SOP Version

    Version 1.0

    Annexure

    1. Peristaltic Pump Operation Log Template

    Date Batch No. Flow Rate (mL/min) Volume (mL) Pumping Time (min) Operator Initials QA Approval
    DD/MM/YYYY Batch Number Flow Rate Measured Volume Dispensed Pumping Time Operator Name QA Name
               


    See also  SOP for Operation of Nasal Spray Filling Machines
    Nasal Spray Formulations Tags:Cleaning SOP for nasal spray equipment, Environmental control in nasal spray production, Equipment maintenance for nasal sprays, Formulating isotonic nasal sprays, Microbial stability in nasal formulations, Mixing SOP for nasal formulations, Nasal spray API formulation, Nasal spray batch manufacturing SOP, Nasal spray filling machine operation, Nasal spray formulation process, Nasal spray GMP guidelines, Nasal spray homogenization techniques, Nasal spray manufacturing process, Nasal spray packaging SOP, Nasal spray preservative-free formulation, Nasal spray production SOP, Nasal spray stability studies, Nasal spray sterilization process, Nasal spray viscosity monitoring, Particle size control in nasal sprays, pH adjustment in nasal formulations, Quality control in nasal spray production, Solvent selection for nasal sprays, SOP for nasal spray manufacturing, SOP for nasal spray testing

    Post navigation

    Previous Post: SOP for Accelerated Stability Testing of Liposome Formulations
    Next Post: SOP for Use of Bioadhesive Polymers in Nanoparticle Formulations

    Standard Operating Procedures V 1.0

    • Aerosols
    • Analytical Method Development
    • Bioequivalence Bioavailability Study
    • Capsule Formulation
    • Clinical Studies
    • Creams
    • Data Integrity
    • Dental Dosage Forms
    • Drug Discovery
    • Environment, Health and Safety
    • Formulation Development
    • Gels
    • Good Distribution Practice
    • Good Warehousing Practices
    • In-Process Control
    • Injectables
    • Liquid Orals
    • Liposome and Emulsion Formulations
    • Lotions
    • Lyophilized Products
    • Maintenance Dept.
    • Medical Devices
    • Metered-Dose Inhaler
    • Microbiology Testing
    • Nanoparticle Formulation
    • Nasal Spray Formulations
    • Nebulizers
    • Ocular (Eye) Dosage Forms
    • Ointments
    • Otic (Ear) Dosage Forms
    • Pharmacovigilance
    • Powder & Granules
    • Purchase Departments
    • Quality Assurance
    • Quality Control
    • Raw Material Stores
    • Regulatory Affairs
    • Tablet Manufacturing
    • Rectal Dosage Forms
    • Transdermal Patches
    • Vaginal Dosage Forms
    • Validations and Qualifications

    Read SOPs in your Language:

     - 
    Bengali
     - 
    bn
    English
     - 
    en
    Gujarati
     - 
    gu
    Hindi
     - 
    hi
    Malayalam
     - 
    ml
    Marathi
     - 
    mr
    Punjabi
     - 
    pa
    Tamil
     - 
    ta
    Telugu
     - 
    te

    NEW! Revised SOPs – V 2.0

    • Aerosols V 2.0
    • Analytical Method Development V 2.0
    • API Manufacturing V 2.0
    • BA-BE Studies V 2.0
    • Biosimilars V 2.0
    • Capsules V 2.0
    • Creams V 2.0
    • Elixers V 2.0
    • Ointments V 2.0
    • Raw Material Warehouse V 2.0
    • Tablet Manufacturing V2.0

    New Publication: A must for All.

    Copyright © 2025 SOP Guide for Pharma.

    Powered by PressBook WordPress theme

    Go to mobile version