Skip to content
  • Clinical Studies
  • Schedule M
  • Stability Studies
  • Pharma GMP
  • Pharma Tips
  • Pharma Books
  • Pharma Validation
  • Pharma Regulatory

SOP Guide for Pharma

The Ultimate Resource for Pharmaceutical SOPs and Best Practices

  • Home
  • Job Safety Analysis (JSA)
    • Oral Dosage Forms (Tablets & Capsules)
    • Oral Liquid Dosage Forms (Syrups, Elixirs, Suspensions, Emulsions)
    • Powder and Granule Dosage Forms
    • Topical Dosage Forms (Creams, Ointments, Gels, Lotions, Pastes)
    • Transdermal Dosage Forms (Patches)
  • Standard Test Procedures (STP)
  • SOP – Blog Post
  • Toggle search form

SOP for Ultrasonic Homogenizer

Posted on By

SOP for Ultrasonic Homogenizer

Standard Operating Procedure for Ultrasonic Homogenizer

1) Purpose

The purpose of this SOP is to describe the procedure for the proper operation and maintenance of the Ultrasonic Homogenizer used in the pharmaceutical manufacturing of otic dosage forms to ensure effective homogenization of liquid formulations.

2) Scope

This SOP applies to all personnel involved in the operation and maintenance of the Ultrasonic Homogenizer in the pharmaceutical manufacturing facility.

3) Responsibilities

Operators: Responsible for correctly operating the Ultrasonic Homogenizer as per this SOP.
Quality Control (QC) Personnel: Responsible for monitoring the quality of homogenization processes.
Maintenance Personnel: Responsible for maintaining the Ultrasonic Homogenizer in proper working condition.

See also  SOP for Tube Crimping Machine

4) Procedure

4.1 Pre-operation Checks
4.1.1 Inspection
4.1.1.1 Inspect the Ultrasonic Homogenizer for cleanliness and integrity before use.
4.1.1.2 Ensure the probe and vessel are clean and free of contaminants.
4.1.1.3 Verify that all safety devices and interlocks are functioning properly.

4.1.2 Preparation
4.1.2.1 Clean and sanitize the Ultrasonic Homogenizer and surrounding area.
4.1.2.2 Set up the homogenization vessel and ensure all utilities (water, power) are connected.
4.1.2.3 Calibrate the Ultrasonic Homogenizer according

to manufacturer specifications.

4.2 Operation
4.2.1 Homogenization Process
4.2.1.1 Start the Ultrasonic Homogenizer and adjust settings as per formulation requirements.
4.2.1.2 Place the formulation into the homogenization vessel and ensure proper immersion of the probe.
4.2.1.3 Monitor homogenization progress and adjust parameters (amplitude, time) if needed.

See also  SOP for Validation of Processes and Methods

4.2.2 Quality Checks
4.2.2.1 Perform visual checks for homogeneity and particle size distribution.
4.2.2.2 Conduct additional tests as required by batch specifications.
4.2.2.3 Record all critical parameters and observations during the homogenization process.

4.3 Post-operation
4.3.1 Shutdown
4.3.1.1 Complete the homogenization process and remove the formulation from the vessel.
4.3.1.2 Clean and sanitize the Ultrasonic Homogenizer and homogenization vessel thoroughly.
4.3.1.3 Perform post-operation checks to ensure no residual material in the Ultrasonic Homogenizer.

4.3.2 Maintenance
4.3.2.1 Disassemble and clean the probe and vessel after each use.
4.3.2.2 Perform regular maintenance checks on power supply and probe integrity.
4.3.2.3 Document all maintenance activities and update maintenance records accordingly.

See also  SOP for Process Chiller

5) Abbreviations, if any

QC: Quality Control
SOP: Standard Operating Procedure

6) Documents, if any

Batch records for each homogenization batch
Maintenance records
Calibration records for the Ultrasonic Homogenizer

7) Reference, if any

Manufacturer’s manual for the Ultrasonic Homogenizer
Pharmacopeial guidelines for pharmaceutical homogenization processes

8) SOP Version

Version 1.0

Otic (Ear) Dosage Forms Tags:Cleaning validation in otic manufacturing, Ear Drops dosage form SOP, Ear Drops SOP, EarDrops SOP, Environmental monitoring in otic manufacturing, GMP for Ear Drops, GMP for otic products, Otic dosage form calibration SOP, Otic dosage form equipment cleaning SOP, Otic dosage form quality assurance, Otic dosage form SOP, Otic drug complaint handling SOP, Otic drug documentation control SOP, Otic drug in-process control SOP, Otic drug stability testing SOP, Otic manufacturing process SOP, Otic product batch record SOP, Otic product deviation handling SOP, Otic product raw material handling SOP, Otic product self-inspection SOP, Otic product vendor qualification SOP, Otic solution SOP, Otic suspension SOP, Quality control for otic dosage forms, SOP for Ear Drops manufacturing, SOP for otic dosage form returned goods, SOP for otic dosage form training, SOP for otic drug manufacturing, SOP for otic formulation development, SOP for otic product labeling, SOP for otic product packaging, SOP for otic product recalls, SOP for otic product release, SOP for otic product sampling

Post navigation

Previous Post: SOP for Membrane Filtration System
Next Post: SOP for Vial Washing Machine

Standard Operating Procedures V 1.0

  • Aerosols
  • Analytical Method Development
  • Bioequivalence Bioavailability Study
  • Capsule Formulation
  • Clinical Studies
  • Creams
  • Data Integrity
  • Dental Dosage Forms
  • Drug Discovery
  • Environment, Health and Safety
  • Formulation Development
  • Gels
  • Good Distribution Practice
  • Good Warehousing Practices
  • In-Process Control
  • Injectables
  • Liquid Orals
  • Liposome and Emulsion Formulations
  • Lotions
  • Lyophilized Products
  • Maintenance Dept.
  • Medical Devices
  • Metered-Dose Inhaler
  • Microbiology Testing
  • Nanoparticle Formulation
  • Nasal Spray Formulations
  • Nebulizers
  • Ocular (Eye) Dosage Forms
  • Ointments
  • Otic (Ear) Dosage Forms
  • Pharmacovigilance
  • Powder & Granules
  • Purchase Departments
  • Quality Assurance
  • Quality Control
  • Raw Material Stores
  • Regulatory Affairs
  • Tablet Manufacturing
  • Rectal Dosage Forms
  • Transdermal Patches
  • Vaginal Dosage Forms
  • Validations and Qualifications

Read SOPs in your Language:

 - 
Bengali
 - 
bn
English
 - 
en
Gujarati
 - 
gu
Hindi
 - 
hi
Malayalam
 - 
ml
Marathi
 - 
mr
Punjabi
 - 
pa
Tamil
 - 
ta
Telugu
 - 
te

NEW! Revised SOPs – V 2.0

  • Aerosols V 2.0
  • Analytical Method Development V 2.0
  • API Manufacturing V 2.0
  • BA-BE Studies V 2.0
  • Biosimilars V 2.0
  • Capsules V 2.0
  • Creams V 2.0
  • Elixers V 2.0
  • Ointments V 2.0
  • Raw Material Warehouse V 2.0
  • Tablet Manufacturing V2.0

New Publication: A must for All.

Copyright © 2025 SOP Guide for Pharma.

Powered by PressBook WordPress theme

Go to mobile version