SOP for Propellant Testing in Aerosols

Posted on By

SOP for Propellant Testing in Aerosols

Standard Operating Procedure for Propellant Testing in Aerosols

1) Purpose

The purpose of this SOP is to outline procedures for testing propellants used in aerosol formulations. Propellant testing ensures the quality, safety, and compliance of aerosol products with regulatory requirements.

2) Scope

This SOP applies to the testing of propellants conducted at [Company Name] for aerosol products, including incoming raw material testing, in-process testing, and release testing of finished products.

3) Responsibilities

Quality Control (QC) Analysts: Responsible for performing propellant testing.
Procurement Team: Responsible for ensuring compliance of incoming propellant batches.
Quality Assurance (QA) Manager: Ensure compliance with testing procedures and documentation.

See also  SOP for Preservative Efficacy Testing in Aerosols

4) Procedure

4.1 Sampling and Preparation:
4.1.1 Obtain representative samples of propellant batches as per sampling plan.
4.1.2 Prepare samples according to specified procedures to ensure consistency and accuracy in testing.

4.2 Physical Characteristics Testing:
4.2.1 Conduct tests to determine physical properties such as pressure, density, and viscosity.
4.2.2 Perform compatibility testing with aerosol valve systems to ensure proper functioning.

4.3 Chemical Composition Analysis:
4.3.1 Analyze propellant composition using techniques such as gas chromatography (GC) or mass spectrometry (MS).
4.3.2 Verify propellant purity and identify any impurities or contaminants.

4.4 Performance Testing:
4.4.1 Evaluate propellant performance under various conditions (e.g., temperature extremes, pressure changes).

/> 4.4.2 Assess propellant stability and shelf-life through accelerated aging studies if applicable.

See also  SOP for Batch Record Review in Aerosol Production

4.5 Compliance Assessment:
4.5.1 Compare test results against acceptance criteria or specifications defined in regulatory standards and product requirements.
4.5.2 Document any deviations or out-of-specification (OOS) results and initiate investigation and corrective actions as per SOPs.

4.6 Reporting:
4.6.1 Document testing procedures, results, and observations in test reports.
4.6.2 Ensure timely review, approval, and distribution of propellant testing reports to relevant stakeholders.

5) Abbreviations, if any

SOP: Standard Operating Procedure
QC: Quality Control
QA: Quality Assurance
GC: Gas Chromatography
MS: Mass Spectrometry

6) Documents, if any

Propellant Testing Protocols
Test Reports
Incident Reports (if applicable)

7) Reference, if any

GMP Guidelines
Pharmacopeial standards (e.g., USP, EP)

See also  SOP for Raw Material Inspection for Aerosols

8) SOP Version

Version 1.0

Aerosols Tags:Aerosol batch manufacturing, Aerosol change control procedures, Aerosol cleaning validation, Aerosol contamination prevention, Aerosol documentation requirements, Aerosol equipment calibration, Aerosol equipment cleaning, Aerosol final product inspection, Aerosol formulation development, Aerosol in-process testing, Aerosol manufacturing process, Aerosol method development, Aerosol microbial testing, Aerosol packaging guidelines, Aerosol particle size analysis, Aerosol personnel training, Aerosol process validation, Aerosol production SOP, Aerosol quality control, Aerosol raw material inspection, Aerosol stability testing, Aerosol stability testing methods, Aerosol sterility maintenance, Aerosol storage conditions, Aerosol waste disposal procedures

Post navigation

Previous Post: SOP for Cleaning Between Batch Runs
Next Post: SOP for Formulation Development Analytical Method Development

Standard Operating Procedures V 1.0

  • Aerosols
  • Analytical Method Development
  • Bioequivalence Bioavailability Study
  • Capsule Formulation
  • Clinical Studies
  • Creams
  • Data Integrity
  • Dental Dosage Forms
  • Drug Discovery
  • Environment, Health and Safety
  • Formulation Development
  • Gels
  • Good Distribution Practice
  • Good Warehousing Practices
  • In-Process Control
  • Injectables
  • Liquid Orals
  • Liposome and Emulsion Formulations
  • Lotions
  • Lyophilized Products
  • Maintenance Dept.
  • Medical Devices
  • Metered-Dose Inhaler
  • Microbiology Testing
  • Nanoparticle Formulation
  • Nasal Spray Formulations
  • Nebulizers
  • Ocular (Eye) Dosage Forms
  • Ointments
  • Otic (Ear) Dosage Forms
  • Pharmacovigilance
  • Powder & Granules
  • Purchase Departments
  • Quality Assurance
  • Quality Control
  • Raw Material Stores
  • Regulatory Affairs
  • Tablet Manufacturing
  • Rectal Dosage Forms
  • Transdermal Patches
  • Vaginal Dosage Forms
  • Validations and Qualifications

Read SOPs in your Language:

 - 
Bengali
 - 
bn
English
 - 
en
Gujarati
 - 
gu
Hindi
 - 
hi
Malayalam
 - 
ml
Marathi
 - 
mr
Punjabi
 - 
pa
Tamil
 - 
ta
Telugu
 - 
te

NEW! Revised SOPs – V 2.0

  • Aerosols V 2.0
  • Analytical Method Development V 2.0
  • API Manufacturing V 2.0
  • BA-BE Studies V 2.0
  • Biosimilars V 2.0
  • Capsules V 2.0
  • Creams V 2.0
  • Elixers V 2.0
  • Ointments V 2.0
  • Raw Material Warehouse V 2.0
  • Tablet Manufacturing V2.0

New Publication: A must for All.

Copyright © 2025 SOP Guide for Pharma.

Powered by PressBook WordPress theme

Go to mobile version