Skip to content
  • Clinical Studies
  • Schedule M
  • Stability Studies
  • Pharma GMP
  • Pharma Tips
  • Pharma Books
  • Pharma Validation
  • Pharma Regulatory

SOP Guide for Pharma

The Ultimate Resource for Pharmaceutical SOPs and Best Practices

  • Home
  • Job Safety Analysis (JSA)
    • Oral Dosage Forms (Tablets & Capsules)
    • Oral Liquid Dosage Forms (Syrups, Elixirs, Suspensions, Emulsions)
    • Powder and Granule Dosage Forms
    • Topical Dosage Forms (Creams, Ointments, Gels, Lotions, Pastes)
    • Transdermal Dosage Forms (Patches)
  • Standard Test Procedures (STP)
  • SOP – Blog Post
  • Toggle search form

SOP for Monitoring Viscosity of Nasal Gels and Suspensions

Posted on By




SOP for Monitoring Viscosity of Nasal Gels and Suspensions



Standard Operating Procedure for Monitoring Viscosity of Nasal Gels and Suspensions

1) Purpose

The purpose of this SOP is to establish a procedure for monitoring and controlling the viscosity of nasal gels and suspensions to ensure product consistency and proper administration.

2) Scope

This SOP applies to all personnel involved in the preparation, testing, and quality control of nasal gels and suspensions at [Company Name].

3) Responsibilities

  • Operators: Responsible for measuring viscosity during the formulation process.
  • QA: Verifies viscosity values and ensures they meet product specifications.
See also  SOP for Standardard Operating Procedure for Preparation an...

4) Procedure

4.1 Viscosity Measurement

4.1.1 Equipment Setup

  • Ensure the viscometer is calibrated and properly set up before testing.
  • Prepare the appropriate spindle size based on the viscosity range of the formulation.

4.1.2 Sampling

  • Take a representative sample of the nasal gel or suspension for viscosity testing.

4.1.3 Testing Procedure

  • Set the viscometer at the appropriate speed and temperature for the test as per formulation requirements.
  • Record the viscosity values (in cP or mPa·s) and check for consistency with formulation specifications.

4.2 Viscosity Adjustment

4.2.1 Adjustment Methods

  • If the viscosity falls outside the target range, adjust the formulation by adding more
gel-forming agents or diluents, depending on the need.
  • Mix thoroughly to ensure homogeneity after any adjustments.
  • 4.3 Documentation

    • Record the viscosity values, any adjustments made, and the final readings in the batch manufacturing record (BMR).
    • Document all viscosity measurements in the viscosity log.

    5) Abbreviations, if any

    • QA: Quality Assurance
    • BMR: Batch Manufacturing Record

    6) Documents, if any

    • Batch Manufacturing Record (BMR)
    • Viscosity Log

    7) References, if any

    • USP 39 – Viscosity Testing in Pharmaceutical Preparations

    8) SOP Version

    Version 1.0

    Annexure

    Viscosity Log Template

    Date Formulation Viscosity (cP) Operator Initials QA Approval
    DD/MM/YYYY Formulation Name Viscosity Operator Name QA Name
               


    See also  SOP for SOP for Manufacturing Nasal Powders Us...
    Nasal Spray Formulations Tags:Cleaning SOP for nasal spray equipment, Environmental control in nasal spray production, Equipment maintenance for nasal sprays, Formulating isotonic nasal sprays, Microbial stability in nasal formulations, Mixing SOP for nasal formulations, Nasal spray API formulation, Nasal spray batch manufacturing SOP, Nasal spray filling machine operation, Nasal spray formulation process, Nasal spray GMP guidelines, Nasal spray homogenization techniques, Nasal spray manufacturing process, Nasal spray packaging SOP, Nasal spray preservative-free formulation, Nasal spray production SOP, Nasal spray stability studies, Nasal spray sterilization process, Nasal spray viscosity monitoring, Particle size control in nasal sprays, pH adjustment in nasal formulations, Quality control in nasal spray production, Solvent selection for nasal sprays, SOP for nasal spray manufacturing, SOP for nasal spray testing

    Post navigation

    Previous Post: SOP for Optimizing Particle Size in Nasal Suspensions
    Next Post: SOP for SOP for pH and Osmolality Control in N…

    Standard Operating Procedures V 1.0

    • Aerosols
    • Analytical Method Development
    • Bioequivalence Bioavailability Study
    • Capsule Formulation
    • Clinical Studies
    • Creams
    • Data Integrity
    • Dental Dosage Forms
    • Drug Discovery
    • Environment, Health and Safety
    • Formulation Development
    • Gels
    • Good Distribution Practice
    • Good Warehousing Practices
    • In-Process Control
    • Injectables
    • Liquid Orals
    • Liposome and Emulsion Formulations
    • Lotions
    • Lyophilized Products
    • Maintenance Dept.
    • Medical Devices
    • Metered-Dose Inhaler
    • Microbiology Testing
    • Nanoparticle Formulation
    • Nasal Spray Formulations
    • Nebulizers
    • Ocular (Eye) Dosage Forms
    • Ointments
    • Otic (Ear) Dosage Forms
    • Pharmacovigilance
    • Powder & Granules
    • Purchase Departments
    • Quality Assurance
    • Quality Control
    • Raw Material Stores
    • Regulatory Affairs
    • Tablet Manufacturing
    • Rectal Dosage Forms
    • Transdermal Patches
    • Vaginal Dosage Forms
    • Validations and Qualifications

    Read SOPs in your Language:

     - 
    Bengali
     - 
    bn
    English
     - 
    en
    Gujarati
     - 
    gu
    Hindi
     - 
    hi
    Malayalam
     - 
    ml
    Marathi
     - 
    mr
    Punjabi
     - 
    pa
    Tamil
     - 
    ta
    Telugu
     - 
    te

    NEW! Revised SOPs – V 2.0

    • Aerosols V 2.0
    • Analytical Method Development V 2.0
    • API Manufacturing V 2.0
    • BA-BE Studies V 2.0
    • Biosimilars V 2.0
    • Capsules V 2.0
    • Creams V 2.0
    • Elixers V 2.0
    • Ointments V 2.0
    • Raw Material Warehouse V 2.0
    • Tablet Manufacturing V2.0

    New Publication: A must for All.

    Copyright © 2025 SOP Guide for Pharma.

    Powered by PressBook WordPress theme

    Go to mobile version