SOP for Lyophilizer

Posted on By

SOP for Lyophilizer

Standard Operating Procedure for Using Lyophilizer

1) Purpose

The purpose of this SOP is to describe the procedure for the proper operation and maintenance of the lyophilizer used in the manufacturing of otic dosage forms to preserve sensitive materials by freeze-drying.

2) Scope

This SOP applies to all personnel involved in the operation and maintenance of the lyophilizer in the pharmaceutical manufacturing facility.

3) Responsibilities

Operators: Responsible for correctly operating the lyophilizer as per this SOP.
Quality Control (QC) Personnel: Responsible for monitoring the lyophilization process and verifying product specifications.
Maintenance Personnel: Responsible for maintaining the lyophilizer in proper working condition.

4) Procedure

4.1 Operation
4.1.1 Preparation
4.1.1.1 Ensure the lyophilizer is on a stable, level surface in a clean room environment.
4.1.1.2 Verify that the shelves and chamber are clean and free of contamination.
4.1.1.3 Check that the vacuum pump and refrigeration system are operational.

See also  SOP for Sterility Test Isolator

4.1.2 Loading the Lyophilizer
4.1.2.1 Prepare the product or solution to be lyophilized in accordance with the batch record.
4.1.2.2 Load the product into suitable containers and arrange them on the lyophilizer shelves.

4.1.2.3 Ensure that containers are spaced adequately for uniform freezing and drying.

4.1.3 Freezing Process
4.1.3.1 Initiate the freezing cycle as per the lyophilizer’s operating procedures.
4.1.3.2 Monitor the temperature of the shelves and product until complete freezing is achieved.
4.1.3.3 Ensure that the product is frozen uniformly without crystallization.

4.1.4 Drying Process
4.1.4.1 Start the drying cycle and gradually reduce the chamber pressure to initiate sublimation.
4.1.4.2 Maintain the appropriate shelf temperature and vacuum levels throughout the drying process.
4.1.4.3 Monitor the progress of drying and adjust parameters if necessary to ensure complete drying.

See also  SOP for Nitrogen Evaporator

4.1.5 Product Removal
4.1.5.1 Once drying is complete, restore normal atmospheric pressure to the chamber.
4.1.5.2 Remove the dried product containers from the lyophilizer and inspect for any signs of moisture.
4.1.5.3 Immediately seal the containers to prevent moisture absorption.

4.2 Calibration
4.2.1 Daily Check
4.2.1.1 Perform a daily check of the lyophilizer’s temperature, vacuum, and pressure settings.
4.2.1.2 Verify the accuracy of the temperature probes and pressure gauges.
4.2.1.3 Record the results in the equipment log.

4.2.2 Monthly Calibration
4.2.2.1 Conduct a full calibration of the lyophilizer monthly using standard test methods.
4.2.2.2 Document the calibration results and any adjustments made.

See also  SOP for Vendor Qualification and Management

4.3 Maintenance
4.3.1 Routine Maintenance
4.3.1.1 Clean the lyophilizer chamber and shelves after each cycle to remove residual product.
4.3.1.2 Inspect and replace vacuum pump oil and filters as recommended by the manufacturer.
4.3.1.3 Lubricate door seals and moving parts to ensure proper sealing and operation.

4.3.2 Troubleshooting
4.3.2.1 If the lyophilizer fails to achieve proper freezing or drying, refer to the manufacturer’s manual for troubleshooting.
4.3.2.2 Contact maintenance personnel for repairs if issues cannot be resolved.

5) Abbreviations, if any

QC: Quality Control
SOP: Standard Operating Procedure

6) Documents, if any

Lyophilization log
Maintenance log

7) Reference, if any

Manufacturer’s manual for the lyophilizer
Regulatory guidelines for equipment calibration and maintenance

8) SOP Version

Version 1.0

Otic (Ear) Dosage Forms Tags:Cleaning validation in otic manufacturing, Ear Drops dosage form SOP, Ear Drops SOP, EarDrops SOP, Environmental monitoring in otic manufacturing, GMP for Ear Drops, GMP for otic products, Otic dosage form calibration SOP, Otic dosage form equipment cleaning SOP, Otic dosage form quality assurance, Otic dosage form SOP, Otic drug complaint handling SOP, Otic drug documentation control SOP, Otic drug in-process control SOP, Otic drug stability testing SOP, Otic manufacturing process SOP, Otic product batch record SOP, Otic product deviation handling SOP, Otic product raw material handling SOP, Otic product self-inspection SOP, Otic product vendor qualification SOP, Otic solution SOP, Otic suspension SOP, Quality control for otic dosage forms, SOP for Ear Drops manufacturing, SOP for otic dosage form returned goods, SOP for otic dosage form training, SOP for otic drug manufacturing, SOP for otic formulation development, SOP for otic product labeling, SOP for otic product packaging, SOP for otic product recalls, SOP for otic product release, SOP for otic product sampling

Post navigation

Previous Post: SOP for Temperature Control System
Next Post: SOP for Internal Audits

Standard Operating Procedures V 1.0

  • Aerosols
  • Analytical Method Development
  • Bioequivalence Bioavailability Study
  • Capsule Formulation
  • Clinical Studies
  • Creams
  • Data Integrity
  • Dental Dosage Forms
  • Drug Discovery
  • Environment, Health and Safety
  • Formulation Development
  • Gels
  • Good Distribution Practice
  • Good Warehousing Practices
  • In-Process Control
  • Injectables
  • Liquid Orals
  • Liposome and Emulsion Formulations
  • Lotions
  • Lyophilized Products
  • Maintenance Dept.
  • Medical Devices
  • Metered-Dose Inhaler
  • Microbiology Testing
  • Nanoparticle Formulation
  • Nasal Spray Formulations
  • Nebulizers
  • Ocular (Eye) Dosage Forms
  • Ointments
  • Otic (Ear) Dosage Forms
  • Pharmacovigilance
  • Powder & Granules
  • Purchase Departments
  • Quality Assurance
  • Quality Control
  • Raw Material Stores
  • Regulatory Affairs
  • Tablet Manufacturing
  • Rectal Dosage Forms
  • Transdermal Patches
  • Vaginal Dosage Forms
  • Validations and Qualifications

Read SOPs in your Language:

 - 
Bengali
 - 
bn
English
 - 
en
Gujarati
 - 
gu
Hindi
 - 
hi
Malayalam
 - 
ml
Marathi
 - 
mr
Punjabi
 - 
pa
Tamil
 - 
ta
Telugu
 - 
te

NEW! Revised SOPs – V 2.0

  • Aerosols V 2.0
  • Analytical Method Development V 2.0
  • API Manufacturing V 2.0
  • BA-BE Studies V 2.0
  • Biosimilars V 2.0
  • Capsules V 2.0
  • Creams V 2.0
  • Elixers V 2.0
  • Ointments V 2.0
  • Raw Material Warehouse V 2.0
  • Tablet Manufacturing V2.0

New Publication: A must for All.

Copyright © 2025 SOP Guide for Pharma.

Powered by PressBook WordPress theme

Go to mobile version