SOP for Energy Control Procedures in MDI Production

Posted on By

SOP for Energy Control Procedures in MDI Production

Energy Control Procedures in MDI Production

1) Purpose

The purpose of this SOP is to establish energy control procedures in metered-dose inhaler (MDI) production to ensure the safety of personnel during maintenance, repair, or adjustment of energy sources and equipment.

2) Scope

This SOP applies to all personnel involved in energy control activities within the MDI production facility, including maintenance technicians, production supervisors, and safety officers.

3) Responsibilities

The responsibilities for this SOP include implementing lockout/tagout procedures, conducting energy isolation, verifying energy sources, and ensuring compliance with safety protocols. Specific roles include:
Maintenance Technicians: Perform energy control procedures and maintain lockout/tagout devices.
Production Supervisors: Oversee energy isolation and authorize equipment shutdown for maintenance.
Safety Officers: Monitor compliance with energy control procedures and conduct periodic audits.

See also  SOP for Supplier Qualification for Raw Materials in MDI Production

4) Procedure

4.1 Energy Control Planning
4.1.1 Identify energy sources (e.g., electrical, mechanical, hydraulic) requiring control during maintenance activities.
4.1.2 Develop energy control plans outlining procedures, responsibilities, and equipment requirements.
4.2 Lockout/Tagout Procedures
4.2.1 Obtain authorization and notify affected personnel before energy isolation.
4.2.2 Apply lockout/tagout devices to energy isolation points to prevent accidental startup.
4.3 Verification of Energy Isolation

/> 4.3.1 Verify energy isolation by testing controls and equipment to ensure energy sources are effectively isolated.
4.3.2 Confirm zero energy state before beginning maintenance or service work.
4.4 Release of Lockout/Tagout
4.4.1 Remove lockout/tagout devices only after completion of maintenance work and verification of safe conditions.
4.4.2 Notify affected personnel and conduct equipment checks before resuming normal operations.

See also  SOP for Conducting Internal Audits in MDI Production

5) Abbreviations, if any

MDI: Metered-Dose Inhaler
SOP: Standard Operating Procedure

6) Documents, if any

Energy control procedures, lockout/tagout plans, equipment isolation checklists, and training records should be maintained.

7) Reference, if any

Refer to regulatory guidelines from agencies such as OSHA (Occupational Safety and Health Administration) for energy control and lockout/tagout requirements in manufacturing environments.

8) SOP Version

Version 1.0

Metered-Dose Inhaler Tags:Analytical Method Development MDIs, Batch Manufacturing Record MDI, Calibration MDI Equipment, Cleaning Equipment MDIs, Color Consistency Testing MDI, Contamination Prevention MDI, Documentation MDI Manufacturing, Final Product Inspection MDI, Formulation Development MDI, In-process Testing Inhalers, Inhaler Manufacturing Procedures, Inhaler Quality Control SOP, Labeling MDI SOP, MDI Production SOPs, MDI Storage Conditions, Metered-Dose Inhaler SOP, Microbial Testing Inhalers, Packaging of MDIs Procedure, Particle Size Analysis MDIs, Preservative Efficacy MDIs, Process Optimization MDIs, Process Validation MDIs, Propellant Testing MDIs, Quality Testing MDIs, Raw Material Inspection MDIs, Solvents Use in MDI Production, Stability Testing MDIs, Sterility Maintenance MDI, Training Personnel MDI Production, Waste Disposal MDI Production

Post navigation

Previous Post: SOP for Equipment Calibration and Maintenance
Next Post: SOP for Suppository Molding Tray

Standard Operating Procedures V 1.0

  • Aerosols
  • Analytical Method Development
  • Bioequivalence Bioavailability Study
  • Capsule Formulation
  • Clinical Studies
  • Creams
  • Data Integrity
  • Dental Dosage Forms
  • Drug Discovery
  • Environment, Health and Safety
  • Formulation Development
  • Gels
  • Good Distribution Practice
  • Good Warehousing Practices
  • In-Process Control
  • Injectables
  • Liquid Orals
  • Liposome and Emulsion Formulations
  • Lotions
  • Lyophilized Products
  • Maintenance Dept.
  • Medical Devices
  • Metered-Dose Inhaler
  • Microbiology Testing
  • Nanoparticle Formulation
  • Nasal Spray Formulations
  • Nebulizers
  • Ocular (Eye) Dosage Forms
  • Ointments
  • Otic (Ear) Dosage Forms
  • Pharmacovigilance
  • Powder & Granules
  • Purchase Departments
  • Quality Assurance
  • Quality Control
  • Raw Material Stores
  • Regulatory Affairs
  • Tablet Manufacturing
  • Rectal Dosage Forms
  • Transdermal Patches
  • Vaginal Dosage Forms
  • Validations and Qualifications

Read SOPs in your Language:

 - 
Bengali
 - 
bn
English
 - 
en
Gujarati
 - 
gu
Hindi
 - 
hi
Malayalam
 - 
ml
Marathi
 - 
mr
Punjabi
 - 
pa
Tamil
 - 
ta
Telugu
 - 
te

NEW! Revised SOPs – V 2.0

  • Aerosols V 2.0
  • Analytical Method Development V 2.0
  • API Manufacturing V 2.0
  • BA-BE Studies V 2.0
  • Biosimilars V 2.0
  • Capsules V 2.0
  • Creams V 2.0
  • Elixers V 2.0
  • Ointments V 2.0
  • Raw Material Warehouse V 2.0
  • Tablet Manufacturing V2.0

New Publication: A must for All.

Copyright © 2025 SOP Guide for Pharma.

Powered by PressBook WordPress theme

Go to mobile version