1) Purpose

The purpose of this SOP is to define the procedures for handling, documenting, and disposing of rejected or scrap materials in medical device manufacturing. This ensures compliance with environmental regulations, prevents unauthorized reuse, and safeguards the integrity of production processes.

2) Scope

This SOP applies to all rejected raw materials, components, in-process products, and finished goods deemed unsuitable for use or sale. It is relevant to production staff, quality assurance personnel, and waste management teams.

3) Responsibilities

– Production Operators: Identify and segregate rejected or scrap materials during manufacturing processes.
– Quality Assurance (QA): Inspect and approve materials for disposal and document non-conformance details.
– Waste Management Team: Handle, transport, and dispose of materials following approved procedures.
– Environmental Compliance Officer: Ensure disposal processes meet local, national, and international environmental regulations.
– Supervisors: Oversee adherence to this SOP and ensure proper documentation.

4) Procedure

4.1 Identification of Rejected or Scrap Materials
4.1.1 Definition of Scrap and Rejected Materials
– Scrap materials: Residual materials generated during production that cannot be reused, such as cut-offs, shavings, or defective components.
– Rejected materials: Items that fail to meet quality

standards during raw material inspection, in-process checks, or final product testing.

See also  SOP for Quality Control Testing of Raw Materials

4.1.2 Identification and Documentation
– Tag rejected or scrap materials immediately with labels specifying the reason for rejection, batch/lot number, and date.
– Record details in the Rejection Log, including material type, quantity, and inspector initials.

4.2 Segregation and Storage
4.2.1 Designated Storage Areas
– Store rejected and scrap materials in designated, clearly labeled areas separate from usable inventory.
– Ensure storage areas are secure, clean, and comply with safety requirements.

4.2.2 Hazardous Materials
– Segregate hazardous scrap materials (e.g., chemical waste) from non-hazardous materials.
– Follow safety protocols for handling and storage to prevent contamination or harm.

4.2.3 Traceability
– Maintain traceability of rejected or scrap materials through batch/lot numbers and detailed records in the Rejection Log.

4.3 Approval for Disposal
4.3.1 Inspection by QA
– QA personnel must inspect all materials marked for disposal to confirm they are unsuitable for use.
– Approve materials for disposal by signing off in the Rejection Log.

4.3.2 Regulatory Review
– Obtain approval from the Environmental Compliance Officer for the disposal of hazardous or regulated materials.
– Verify that disposal methods align with local and international environmental laws.

See also  SOP for Documentation of CAPA in Quality Assurance

4.4 Disposal Methods
4.4.1 Non-Hazardous Materials
– Dispose of non-hazardous scrap materials through recycling or general waste disposal methods, as applicable.
– Document the disposal method and service provider details in the Disposal Log.

4.4.2 Hazardous Materials
– Transport hazardous materials to certified waste disposal facilities in compliance with regulatory standards.
– Ensure that transporters hold valid permits for handling hazardous waste.

4.4.3 Destruction of Rejected Products
– For rejected finished products, ensure destruction is irreversible to prevent unauthorized reuse.
– Use shredding, incineration, or chemical neutralization methods, as appropriate.

4.4.4 Recycling
– Identify scrap materials suitable for recycling and coordinate with approved recycling vendors.
– Ensure recycled materials do not re-enter the production process unless approved for specific purposes.

4.5 Documentation and Record Keeping
4.5.1 Rejection Log
– Record all rejected materials in the Rejection Log, including material type, batch/lot number, quantity, and reason for rejection.

4.5.2 Disposal Log
– Maintain a Disposal Log documenting material type, disposal method, date, and responsible personnel.
– Include vendor details and certifications for hazardous waste disposal or recycling activities.

4.5.3 Certificates of Disposal
– Obtain certificates of disposal or destruction from waste disposal vendors for hazardous and rejected materials.
– Archive certificates as part of the disposal records.

See also  SOP for Prototyping Medical Devices

4.6 Auditing and Compliance
4.6.1 Internal Audits
– Conduct regular internal audits to ensure adherence to this SOP and proper record-keeping.
– Address any non-compliance through corrective actions.

4.6.2 Regulatory Inspections
– Ensure all disposal records are readily accessible for regulatory inspections.
– Provide required documentation, such as disposal logs and certificates, to demonstrate compliance.

5) Abbreviations

– QA: Quality Assurance
– SOP: Standard Operating Procedure
– EPA: Environmental Protection Agency

6) Documents

– Rejection Log
– Disposal Log
– Certificates of Disposal/Destruction
– Regulatory Compliance Records
– Vendor Certifications

7) Reference

– ISO 14001: Environmental management systems
– FDA CFR Title 21, Part 820: Quality System Regulation
– Local Environmental Protection Regulations
– Basel Convention on the Control of Transboundary Movements of Hazardous Wastes

8) SOP Version

– Version: 1.0
– Effective Date: DD/MM/YYYY
– Approved by: [Name/Title]

Annexure

Annexure 1: Rejection Log Template

Date Material Type Batch/Lot Number Reason for Rejection Quantity Inspector
DD/MM/YYYY Material Name Batch ID Non-Conformance Details Quantity Inspector Name

Annexure 2: Disposal Log Template

Date Material Type Batch/Lot Number Disposal Method Vendor Certificate Number
DD/MM/YYYY Material Name Batch ID Recycling/Incineration Vendor Name Certificate ID
Medical Devices Tags:FDA Medical device SOP requirements, GMP SOP for medical devices, ISO 13485 SOP for Medical device, Medical device compliance SOP, Medical device packaging SOP template, Medical device post-market surveillance SOP, Medical device quality control SOP, Medical device quality SOP, Medical device regulatory SOP, Medical device SOP, SOP for change control in medical device, SOP for device design control, SOP for equipment calibration in medical devices, SOP for handling complaints in medical devices, SOP for manufacturing medical devices, SOP for medical device audits, SOP for medical device inspection, SOP for medical device labeling, SOP for medical device manufacturing, SOP for medical device packaging inspection, SOP for Medical device raw material, SOP for medical device testing, SOP for non-conforming products in medical devices, SOP for packaging medical devices, SOP for product validation, SOP for production planning in medical devices, SOP for risk management in medical devices, SOP for sterilization packaging validation, SOP for sterilization process of Medical device, SOP for traceability in medical device manufacturing

Post navigation

Previous Post: Capsule: SOP for Preventive Maintenance of Capsule Manufacturing Equipment – V 2.0
Next Post: Creams: SOP for Scale-Up Studies in Cream Manufacturing – V 2.0

Standard Operating Procedures V 1.0

  • Aerosols
  • Analytical Method Development
  • Bioequivalence Bioavailability Study
  • Capsule Formulation
  • Clinical Studies
  • Creams
  • Data Integrity
  • Dental Dosage Forms
  • Drug Discovery
  • Environment, Health and Safety
  • Formulation Development
  • Gels
  • Good Distribution Practice
  • Good Warehousing Practices
  • In-Process Control
  • Injectables
  • Liquid Orals
  • Liposome and Emulsion Formulations
  • Lotions
  • Lyophilized Products
  • Maintenance Dept.
  • Medical Devices
  • Metered-Dose Inhaler
  • Microbiology Testing
  • Nanoparticle Formulation
  • Nasal Spray Formulations
  • Nebulizers
  • Ocular (Eye) Dosage Forms
  • Ointments
  • Otic (Ear) Dosage Forms
  • Pharmacovigilance
  • Powder & Granules
  • Purchase Departments
  • Quality Assurance
  • Quality Control
  • Raw Material Stores
  • Regulatory Affairs
  • Tablet Manufacturing
  • Rectal Dosage Forms
  • Transdermal Patches
  • Vaginal Dosage Forms
  • Validations and Qualifications

Read SOPs in your Language:

 - 
Bengali
 - 
bn
English
 - 
en
Gujarati
 - 
gu
Hindi
 - 
hi
Malayalam
 - 
ml
Marathi
 - 
mr
Punjabi
 - 
pa
Tamil
 - 
ta
Telugu
 - 
te

NEW! Revised SOPs – V 2.0

  • Aerosols V 2.0
  • Analytical Method Development V 2.0
  • API Manufacturing V 2.0
  • BA-BE Studies V 2.0
  • Biosimilars V 2.0
  • Capsules V 2.0
  • Creams V 2.0
  • Elixers V 2.0
  • Ointments V 2.0
  • Raw Material Warehouse V 2.0
  • Tablet Manufacturing V2.0

New Publication: A must for All.

Copyright © 2025 SOP Guide for Pharma.

Powered by PressBook WordPress theme

Go to mobile version