SOP for Cleanroom Maintenance and Monitoring

Posted on By

SOP for Cleanroom Maintenance and Monitoring

Comprehensive Guide to Cleanroom Maintenance and Monitoring for Medical Device Manufacturing

1) Purpose

The purpose of this SOP is to establish a standardized process for maintaining and monitoring cleanrooms used in the manufacturing of medical devices. Proper cleanroom management ensures that the environment is controlled to prevent contamination and meet regulatory and quality standards.

2) Scope

This SOP applies to all cleanroom environments used in the production, assembly, and testing of medical devices. It is relevant to manufacturing, quality assurance, facilities management, and regulatory affairs teams.

3) Responsibilities

– Facilities Management Team: Ensures the cleanroom is properly maintained and meets environmental standards.
– Quality Assurance (QA): Verifies cleanroom compliance with cleanliness standards, operational procedures, and regulatory requirements.
– Manufacturing Team: Operates within cleanroom environments and adheres to procedures for contamination control.
– Environmental Monitoring Team: Monitors and records cleanroom parameters such as temperature, humidity, and particle count.
– Regulatory Affairs: Ensures cleanroom practices comply with regulatory requirements (e.g., FDA, EU MDR).

4) Procedure

4.1 Cleanroom Classification and Design
4.1.1 Classifying Cleanroom Environments
– Classify cleanrooms based on cleanliness levels, such as:
– Class 1: Ultra-clean environment, typically used for critical device manufacturing.
– Class 10,000: Suitable for general medical device assembly.
– Class 100,000: For non-critical device assembly or testing.

4.1.2 Cleanroom Design
– Ensure cleanrooms are designed to minimize contamination risks, including:
– Proper air filtration systems (e.g., HEPA filters).
– Controlled airflow to prevent contamination.
– Non-porous, easy-to-clean surfaces.
– Adequate space for personnel, equipment, and material flow.

See also  SOP for Manufacturing Process Validation (IQ, OQ, PQ)

4.1.3 Environmental Control
– Install and maintain systems to control:
– Temperature and humidity levels within specified limits.
– Air pressure differential between cleanroom and surrounding areas.
– Air filtration and air exchange rates.

4.2 Cleanroom Maintenance
4.2.1 Cleaning Procedures
– Establish cleaning protocols to maintain cleanliness and prevent contamination, including:
– Daily cleaning of floors, walls, and surfaces.
– Regular disinfection of high-touch areas.
– Specific cleaning methods for different cleanroom classifications.
– Cleaning schedules and checklists.

4.2.2 Equipment and Materials Maintenance
– Ensure that equipment used within the cleanroom is properly cleaned, maintained, and calibrated, including:
– Cleaning of machinery and tools after each use.
– Calibration of instruments used for environmental monitoring.
– Proper storage and handling of materials to avoid contamination.

4.2.3 Personnel Hygiene and Procedures
– Implement hygiene protocols for personnel working in the cleanroom:
– Mandatory gowning procedures (e.g., lab coats, gloves, face masks).
– Use of non-shedding materials for clothing and equipment.
– Training for personnel on contamination control practices.

4.2.4 Documentation of Maintenance
– Maintain records of cleaning and maintenance activities, including:
– Cleaning logs detailing dates, tasks completed, and personnel responsible.
– Equipment maintenance and calibration records.
– Personnel training records.

4.3 Environmental Monitoring and Control
4.3.1 Monitoring Cleanroom Parameters
– Continuously monitor critical environmental parameters, including:
– Temperature and humidity.
– Airborne particle count (e.g., using particle counters).
– Air pressure differential and airflow velocity.
– Use automated systems for real-time monitoring and alerting for deviations.

See also  SOP for Batch Record Documentation in Manufacturing

4.3.2 Sampling and Testing
– Conduct regular sampling and testing of cleanroom conditions:
– Air samples to check for microbial contamination.
– Surface samples to monitor for particulates and bacteria.
– Set test frequency based on cleanroom classification and production requirements.

4.3.3 Documenting Environmental Data
– Record monitoring results in the Environmental Monitoring Log, including:
– Test results for airborne particles, temperature, and humidity.
– Corrective actions taken for any deviations from acceptable limits.
– Documentation of cleaning and maintenance schedules.

4.4 Cleanroom Certification and Qualification
4.4.1 Equipment and Facility Qualification
– Perform regular qualification of cleanroom equipment and systems, including:
– Installation Qualification (IQ): Ensuring that equipment is installed properly and meets design specifications.
– Operational Qualification (OQ): Verifying that equipment operates within the required parameters.
– Performance Qualification (PQ): Ensuring equipment performs consistently under actual operating conditions.

4.4.2 Certification Process
– Certify cleanroom environments according to applicable standards:
– ISO 14644 for cleanroom classification.
– FDA guidelines for manufacturing environments.
– Maintain certificates of compliance and ensure recertification is conducted at specified intervals.

4.5 Non-Conformance and Corrective Actions
4.5.1 Identifying Non-Conformance
– Detect and document any non-conformance related to cleanroom conditions, such as:
– Deviations in temperature, humidity, or particle count.
– Contamination incidents or equipment failures.
– Personnel breaches of hygiene protocols.

4.5.2 Corrective and Preventive Actions (CAPA)
– Implement CAPA procedures for any non-conformance:
– Investigate the root cause of deviations.
– Apply corrective actions to address the issue.
– Prevent recurrence by revising procedures, equipment, or training.

See also  SOP for Documenting Hazard Analysis and Critical Control Points (HACCP) in Medical Devices

4.5.3 Documenting Corrective Actions
– Record CAPA activities in the CAPA Log, including:
– Description of the issue and root cause.
– Corrective actions taken and their outcomes.
– Preventive measures and monitoring procedures implemented.

4.6 Documentation and Record Keeping
4.6.1 Cleanroom Documentation File
– Maintain a cleanroom documentation file that includes:
– Cleanroom classification and design specifications.
– Cleaning and maintenance logs.
– Environmental monitoring records.
– Qualification and certification documents.
– CAPA records related to cleanroom performance.

4.6.2 Retention Period
– Retain records for a minimum of five years or as required by regulatory authorities.

5) Abbreviations

– QA: Quality Assurance
– CAPA: Corrective and Preventive Actions
– SOP: Standard Operating Procedure
– IQ: Installation Qualification
– OQ: Operational Qualification
– PQ: Performance Qualification
– ISO: International Organization for Standardization

6) Documents

– Cleanroom Maintenance Logs
– Environmental Monitoring Log
– CAPA Log
– Qualification and Certification Documents
– Personnel Training Records

7) Reference

– ISO 14644: Cleanrooms and Associated Controlled Environments
– FDA 21 CFR Part 820: Quality System Regulation
– EU MDR (Regulation (EU) 2017/745): General Safety and Performance Requirements
– ISO 13485: Medical Devices – Quality Management Systems

8) SOP Version

– Version: 1.0
– Effective Date: DD/MM/YYYY
– Approved by: [Name/Title]

Annexure

Annexure 1: Environmental Monitoring Log Template

Date Test ID Parameter Monitored Result Corrective Actions Taken
DD/MM/YYYY EM-001 Particle Count Pass No action required

Annexure 2: Cleanroom Maintenance Log Template

Date Task Performed Performed By Remarks
DD/MM/YYYY Cleaning of walls and floors Facilities Team Completed as per SOP
Medical Devices Tags:FDA Medical device SOP requirements, GMP SOP for medical devices, ISO 13485 SOP for Medical device, Medical device compliance SOP, Medical device packaging SOP template, Medical device post-market surveillance SOP, Medical device quality control SOP, Medical device quality SOP, Medical device regulatory SOP, Medical device SOP, SOP for change control in medical device, SOP for device design control, SOP for equipment calibration in medical devices, SOP for handling complaints in medical devices, SOP for manufacturing medical devices, SOP for medical device audits, SOP for medical device inspection, SOP for medical device labeling, SOP for medical device manufacturing, SOP for medical device packaging inspection, SOP for Medical device raw material, SOP for medical device testing, SOP for non-conforming products in medical devices, SOP for packaging medical devices, SOP for product validation, SOP for production planning in medical devices, SOP for risk management in medical devices, SOP for sterilization packaging validation, SOP for sterilization process of Medical device, SOP for traceability in medical device manufacturing

Post navigation

Previous Post: SOP for Handling and Storing Hazardous Materials in the Facility
Next Post: SOP for Documenting Software Development in Medical Devices

Standard Operating Procedures V 1.0

  • Aerosols
  • Analytical Method Development
  • Bioequivalence Bioavailability Study
  • Capsule Formulation
  • Clinical Studies
  • Creams
  • Data Integrity
  • Dental Dosage Forms
  • Drug Discovery
  • Environment, Health and Safety
  • Formulation Development
  • Gels
  • Good Distribution Practice
  • Good Warehousing Practices
  • In-Process Control
  • Injectables
  • Liquid Orals
  • Liposome and Emulsion Formulations
  • Lotions
  • Lyophilized Products
  • Maintenance Dept.
  • Medical Devices
  • Metered-Dose Inhaler
  • Microbiology Testing
  • Nanoparticle Formulation
  • Nasal Spray Formulations
  • Nebulizers
  • Ocular (Eye) Dosage Forms
  • Ointments
  • Otic (Ear) Dosage Forms
  • Pharmacovigilance
  • Powder & Granules
  • Purchase Departments
  • Quality Assurance
  • Quality Control
  • Raw Material Stores
  • Regulatory Affairs
  • Tablet Manufacturing
  • Rectal Dosage Forms
  • Transdermal Patches
  • Vaginal Dosage Forms
  • Validations and Qualifications

Read SOPs in your Language:

 - 
Bengali
 - 
bn
English
 - 
en
Gujarati
 - 
gu
Hindi
 - 
hi
Malayalam
 - 
ml
Marathi
 - 
mr
Punjabi
 - 
pa
Tamil
 - 
ta
Telugu
 - 
te

NEW! Revised SOPs – V 2.0

  • Aerosols V 2.0
  • Analytical Method Development V 2.0
  • API Manufacturing V 2.0
  • BA-BE Studies V 2.0
  • Biosimilars V 2.0
  • Capsules V 2.0
  • Creams V 2.0
  • Elixers V 2.0
  • Ointments V 2.0
  • Raw Material Warehouse V 2.0
  • Tablet Manufacturing V2.0

New Publication: A must for All.

Copyright © 2025 SOP Guide for Pharma.

Powered by PressBook WordPress theme

Go to mobile version