SOP for Cleaning Of Dehumidifier

Posted on By

Standard Operating Procedure for Cleaning of Dehumidifier

1. Purpose

The purpose of this SOP is to provide guidelines for the proper cleaning and maintenance of the dehumidifier in order to maintain a controlled environment in compliance with pharmaceutical industry standards.

2. Scope

This SOP applies to all personnel responsible for the operation and maintenance of the dehumidifier within the pharmaceutical facility.

3. Responsibilities

  • 3.1 Operator: Responsible for conducting routine cleaning of the dehumidifier.
  • 3.2 Supervisor: Responsible for overseeing and ensuring compliance with this SOP.
  • 3.3 Maintenance Team: Responsible for any major repairs or servicing of the dehumidifier.
See also  SOP for Operation of Bottle Inspection Machine

4. Procedure

Follow these steps for the proper cleaning of the dehumidifier:

4.1 Ensure the dehumidifier is powered off and disconnected from the electrical supply.

4.2 Put on appropriate personal protective equipment (PPE), including gloves and safety goggles.

4.3 Remove and dispose of any air filters or pre-filters according to waste disposal procedures.

4.4 Use a soft, lint-free cloth or sponge dampened with a mild detergent solution to wipe down the interior and exterior surfaces of the dehumidifier.

4.5 Pay special attention to areas prone to dust and dirt accumulation, such as coils and fans.

4.6 Rinse the cloth or sponge thoroughly and wipe down all surfaces again to remove any detergent residue.

See also  SOP for Cleaning of High Shear Mixer

4.7 Allow all cleaned components to air

dry completely.

4.8 Reinstall air filters or pre-filters if applicable.

4.9 Reconnect the dehumidifier to the electrical supply and power it on.

4.10 Conduct a functional check to ensure the dehumidifier is operating correctly.

4.11 Record the cleaning and maintenance activities in the equipment logbook.

5. Abbreviations

No specific abbreviations are used in this SOP.

6. Documents

The following documents are relevant to this SOP:

  • Equipment Logbook
  • Manufacturer’s Maintenance Manual

7. References

No external references are applicable to this SOP.

8. SOP Version

This is Version 1.0 of the SOP for Cleaning of Dehumidifier, issued on [Date].

See also  SOP for Equipment Cleaning Validation
Liquid Orals Tags:Batch documentation for oral liquids, GMP for liquid orals, Liquid dosage form guidelines, Liquid oral batch release, Liquid oral manufacturing SOP, Liquid oral pharmaceutical facility, liquid oral pharmaceutical SOPs, Liquid oral process validation, Liquid oral product testing, Liquid oral storage conditions, Oral liquid labeling requirements, Oral solution quality assurance, Oral solution SOP, Oral suspension procedure, Packaging of liquid orals, Pharmaceutical liquid dosage SOP, Pharmaceutical liquid formulations, Quality control in liquid oral production, Regulatory compliance for liquid oral products, SOP for flavoring in oral liquids, SOP for syrup manufacturing

Post navigation

Previous Post: SOP for Batch Sampling and Testing
Next Post: SOP for Cleaning of Sifter

Standard Operating Procedures V 1.0

  • Aerosols
  • Analytical Method Development
  • Bioequivalence Bioavailability Study
  • Capsule Formulation
  • Clinical Studies
  • Creams
  • Data Integrity
  • Dental Dosage Forms
  • Drug Discovery
  • Environment, Health and Safety
  • Formulation Development
  • Gels
  • Good Distribution Practice
  • Good Warehousing Practices
  • In-Process Control
  • Injectables
  • Liquid Orals
  • Liposome and Emulsion Formulations
  • Lotions
  • Lyophilized Products
  • Maintenance Dept.
  • Medical Devices
  • Metered-Dose Inhaler
  • Microbiology Testing
  • Nanoparticle Formulation
  • Nasal Spray Formulations
  • Nebulizers
  • Ocular (Eye) Dosage Forms
  • Ointments
  • Otic (Ear) Dosage Forms
  • Pharmacovigilance
  • Powder & Granules
  • Purchase Departments
  • Quality Assurance
  • Quality Control
  • Raw Material Stores
  • Regulatory Affairs
  • Tablet Manufacturing
  • Rectal Dosage Forms
  • Transdermal Patches
  • Vaginal Dosage Forms
  • Validations and Qualifications

Read SOPs in your Language:

 - 
Bengali
 - 
bn
English
 - 
en
Gujarati
 - 
gu
Hindi
 - 
hi
Malayalam
 - 
ml
Marathi
 - 
mr
Punjabi
 - 
pa
Tamil
 - 
ta
Telugu
 - 
te

NEW! Revised SOPs – V 2.0

  • Aerosols V 2.0
  • Analytical Method Development V 2.0
  • API Manufacturing V 2.0
  • BA-BE Studies V 2.0
  • Biosimilars V 2.0
  • Capsules V 2.0
  • Creams V 2.0
  • Elixers V 2.0
  • Ointments V 2.0
  • Raw Material Warehouse V 2.0
  • Tablet Manufacturing V2.0

New Publication: A must for All.

Copyright © 2025 SOP Guide for Pharma.

Powered by PressBook WordPress theme

Go to mobile version