Skip to content
  • Clinical Studies
  • Schedule M
  • Stability Studies
  • Pharma GMP
  • Pharma Tips
  • Pharma Books
  • Pharma Validation
  • Pharma Regulatory

SOP Guide for Pharma

The Ultimate Resource for Pharmaceutical SOPs and Best Practices

  • Home
  • SOP Guidelines
    • SOP Development
    • SOP Training
    • SOP Compliance Monitoring
    • SOP Revision Processes
    • Pharmaceutical SOP templates
    • GMP documentation SOP
    • Data integrity SOP pharma
    • Manufacturing SOP pharmaceutical
    • FDA SOP guidance
    • eQMS SOP workflows
  • Job Safety Analysis (JSA)
    • Oral Dosage Forms (Tablets & Capsules)
    • Oral Liquid Dosage Forms (Syrups, Elixirs, Suspensions, Emulsions)
    • Powder and Granule Dosage Forms
    • Topical Dosage Forms (Creams, Ointments, Gels, Lotions, Pastes)
    • Transdermal Dosage Forms (Patches)
  • Standard Test Procedures (STP)
  • GMP Audit Findings
    • Non-Compliance
      • SOP Absence
      • Revision Control
      • Non-Adherence
      • Poor Writing
      • Training Failure
      • Data Integrity Gaps
      • Mismatch Between SOPs and Practice
      • Critical Operations
      • Regulatory Change
      • Emergency Changes
      • Third-Party SOPs
      • Inspection Readiness
      • Deviation Handling
      • CAPA Integration
      • Validation Alignment
      • System Integration
      • Uncontrolled Distribution
      • SOP Implementation Gaps
      • SOP Alignment with Validation
      • Change Control Linkage
  • Toggle search form

Manufacturing: SOP for Ensuring Proper Mixing during Solution Preparation – V 2.0

Posted on By

Manufacturing: SOP for Ensuring Proper Mixing during Solution Preparation – V 2.0

Standard Operating Procedure for Ensuring Proper Mixing during Solution Preparation


Department Manufacturing
SOP No. SOP/MFG/174/2025
Supersedes SOP/MFG/174/2022
Page No. Page 1 of 15
Issue Date 24/06/2025
Effective Date 25/06/2025
Review Date 24/06/2026

1. Purpose

This SOP describes the procedure for ensuring uniform and consistent mixing of raw materials and excipients during solution preparation for sterile injectable products. Proper mixing is critical for achieving homogeneity, reproducibility, and compliance with GMP and product specifications.

2. Scope

This procedure is applicable to

all batch sizes and formulations of sterile injectable products prepared in the solution preparation area at [Insert Company Name].

3. Responsibilities

  • Manufacturing Operator: To perform solution preparation and mixing as per instructions and document observations.
  • Manufacturing Supervisor: To verify process parameters, supervise activities, and ensure compliance with the Master Formula Record (MFR).
  • IPQA Officer: To monitor critical mixing steps, perform in-process checks, and verify homogeneity.
  • Engineering Personnel: To ensure mixing equipment is calibrated, qualified, and maintained.

4. Accountability

The Head of Manufacturing is accountable for ensuring adherence to the proper mixing procedure and maintaining GMP compliance throughout the operation.

See also  Sterile Injectable Manufacturing: SOP for Dispensing Materials for Intramuscular Injections - V 2.0

5. Procedure

5.1 Pre-Mixing Preparation

  1. Verify the cleanliness status of the solution preparation vessel and mixing equipment.
  2. Ensure equipment has valid calibration and cleaning tags attached.
  3. Confirm the batch number, product name, and MFR before initiating the process.
  4. Cross-check the weighed raw materials (active and inactive) with the Material Dispensing Log.
  5. Check availability of purified water for injection (WFI), utilities, and environmental conditions (temperature, RH).
  6. Ensure that all personnel involved are in sterile gowning and trained for aseptic handling.

5.2 Equipment Setup

  1. Connect the mechanical stirrer, homogenizer, or magnetic mixer to the preparation vessel as per the MFR.
  2. Ensure speed controllers and timers are functional.
  3. Start a 10-minute pre-operation test run to confirm operational readiness of mixing system.

5.3 Addition of Ingredients

  1. Start with the specified volume of WFI as mentioned in the MFR.
  2. Add ingredients in a stepwise and sequential manner:
    • Dissolve excipients first (e.g., buffers, stabilizers)
    • Then add active pharmaceutical ingredients (APIs)
    • Add pH adjusters and preservatives as per instruction
  3. Record each addition in the Solution Preparation Log (Annexure-1).
  4. Monitor temperature during mixing, especially for heat-sensitive compounds.

5.4 Mixing Parameters

  1. Operate the mixer at predefined RPM (e.g., 150–300 RPM) for the time specified in the MFR (e.g., 30–90 minutes).
  2. Ensure vortex formation (if required) does not lead to air entrapment.
  3. Continue mixing until a clear, particle-free, and homogenous solution is achieved.
  4. Record start and stop times for each mixing stage.
See also  Sterile Injection Manufacturing: SOP for Inspection of Cartons Used for Injectable Packing - V 2.0

5.5 In-Process Verification of Mixing

  1. Take 3 samples from:
    • Top layer
    • Middle layer
    • Bottom layer
  2. Submit samples to QC for:
    • pH test
    • Assay or content uniformity
    • Visual appearance
  3. Results should meet specifications to proceed to the next step.
  4. IPQA Officer must sign off the Solution Preparation Log upon approval.

5.6 Post-Mixing Activities

  1. Transfer the final bulk solution through a 0.22 μm pre-filtration unit to the holding vessel.
  2. Label the bulk with name, batch number, volume, and date using the Bulk Holding Label (Annexure-2).
  3. Ensure solution is stored under controlled temperature until further processing (e.g., sterile filtration).

5.7 Deviations and Troubleshooting

  1. If incomplete dissolution is observed:
    • Continue mixing under same conditions for additional 15–30 minutes
    • Report to Supervisor and QA if no improvement occurs
  2. If foaming occurs:
    • Reduce RPM
    • Use defoamers only if mentioned in the MFR and approved by QA
  3. Document any deviation in the Deviation Report (Annexure-3).
See also  Sterile Injectable Manufacturing: SOP for Formulation Development of Intramuscular Injections - V 2.0

6. Abbreviations

  • SOP: Standard Operating Procedure
  • MFR: Master Formula Record
  • WFI: Water for Injection
  • IPQA: In-Process Quality Assurance
  • RPM: Revolutions per Minute
  • QA: Quality Assurance

7. Documents

  1. Solution Preparation Log – Annexure-1
  2. Bulk Holding Label – Annexure-2
  3. Deviation Report – Annexure-3

8. References

  • WHO Guidelines on Good Manufacturing Practices
  • EU GMP Annex 1
  • ICH Q8 – Pharmaceutical Development

9. SOP Version

Version: 2.0

10. Approval Section

Prepared By Checked By Approved By
Signature
Date
Name
Designation Manufacturing Executive QA Executive Head QA
Department Production Quality Assurance Quality Assurance

11. Annexures

Annexure-1: Solution Preparation Log

Date Batch No. Material Added Time Operator
24/06/2025 INJ0625-001 Sodium Chloride 10:30 AM Rajesh Kumar

Annexure-2: Bulk Holding Label

Product Name Sodium Chloride Injection
Batch No. INJ0625-001
Volume 120 L
Date of Preparation 24/06/2025
Status Hold for Sterile Filtration

Annexure-3: Deviation Report

Date Batch No. Deviation Observed Action Taken Approved By
24/06/2025 INJ0625-001 Incomplete Dissolution Extended Mixing by 20 Minutes Sunita Reddy

Revision History:

Revision Date Revision No. Details Reason Approved By
01/01/2022 1.0 Initial Release New SOP QA Head
24/06/2025 2.0 Included troubleshooting and verification process Annual Review QA Head
Injectables V 2.0 Tags:Aseptic processing SOP, Aseptic technique in sterile manufacturing, Cleanroom SOP for injectables, SOP for ampoule sealing, SOP for autoclave sterilization, SOP for container closure integrity testing, SOP for environmental monitoring in aseptic area, SOP for gowning in cleanroom, SOP for in-process checks in sterile manufacturing, SOP for injectable formulation, SOP for lyophilizer operation, SOP for sterile filtration, SOP for sterilization validation, SOP for vial filling, SOP for visual inspection of injectables, Sterile area cleaning SOP, Sterile filling line SOP, Sterile injectable quality control SOP, Sterile injection SOP, Sterile manufacturing procedure

Post navigation

Previous Post: Elixir Department: SOP for Cleaning Low Volume Transfer Hoses – V 2.0
Next Post: How to Train Operators on Visual SOPs and Aids

Standard Operating Procedures V 1.0

  • Aerosols
  • Analytical Method Development
  • Bioequivalence Bioavailability Study
  • Capsule Formulation
  • Clinical Studies
  • Creams
  • Data Integrity
  • Dental Dosage Forms
  • Drug Discovery
  • Environment, Health and Safety
  • Formulation Development
  • Gels
  • Good Distribution Practice
  • Good Warehousing Practices
  • In-Process Control
  • Injectables
  • Liquid Orals
  • Liposome and Emulsion Formulations
  • Lotions
  • Lyophilized Products
  • Maintenance Dept.
  • Medical Devices
  • Metered-Dose Inhaler
  • Microbiology Testing
  • Nanoparticle Formulation
  • Nasal Spray Formulations
  • Nebulizers
  • Ocular (Eye) Dosage Forms
  • Ointments
  • Otic (Ear) Dosage Forms
  • Pharmacovigilance
  • Powder & Granules
  • Purchase Departments
  • Quality Assurance
  • Quality Control
  • Raw Material Stores
  • Regulatory Affairs
  • Tablet Manufacturing
  • Rectal Dosage Forms
  • Transdermal Patches
  • Vaginal Dosage Forms
  • Validations and Qualifications

Read SOPs in your Language:

 - 
Bengali
 - 
bn
English
 - 
en
Gujarati
 - 
gu
Hindi
 - 
hi
Malayalam
 - 
ml
Marathi
 - 
mr
Punjabi
 - 
pa
Tamil
 - 
ta
Telugu
 - 
te

NEW! Revised SOPs – V 2.0

  • Aerosols V 2.0
  • Analytical Method Development V 2.0
  • API Manufacturing V 2.0
  • BA-BE Studies V 2.0
  • Biosimilars V 2.0
  • Capsules V 2.0
  • Creams V 2.0
  • Elixers V 2.0
  • Gels V 2.0
  • Injectables V 2.0
  • Ointments V 2.0
  • Raw Material Warehouse V 2.0
  • Tablet Manufacturing V2.0

New Publication: A must for All.

Copyright © 2026 SOP Guide for Pharma.

Powered by PressBook WordPress theme

Go to mobile version