Skip to content
  • Clinical Studies
  • Schedule M
  • Stability Studies
  • Pharma GMP
  • Pharma Tips
  • Pharma Books
  • Pharma Validation
  • Pharma Regulatory

SOP Guide for Pharma

The Ultimate Resource for Pharmaceutical SOPs and Best Practices

  • Home
  • SOP Guidelines
    • SOP Development
    • SOP Training
    • SOP Compliance Monitoring
    • SOP Revision Processes
    • Pharmaceutical SOP templates
    • GMP documentation SOP
    • Data integrity SOP pharma
    • Manufacturing SOP pharmaceutical
    • FDA SOP guidance
    • eQMS SOP workflows
  • Job Safety Analysis (JSA)
    • Oral Dosage Forms (Tablets & Capsules)
    • Oral Liquid Dosage Forms (Syrups, Elixirs, Suspensions, Emulsions)
    • Powder and Granule Dosage Forms
    • Topical Dosage Forms (Creams, Ointments, Gels, Lotions, Pastes)
    • Transdermal Dosage Forms (Patches)
  • Standard Test Procedures (STP)
  • GMP Audit Findings
    • Non-Compliance
      • SOP Absence
      • Revision Control
      • Non-Adherence
      • Poor Writing
      • Training Failure
      • Data Integrity Gaps
      • Mismatch Between SOPs and Practice
      • Critical Operations
      • Regulatory Change
      • Emergency Changes
      • Third-Party SOPs
      • Inspection Readiness
      • Deviation Handling
      • CAPA Integration
      • Validation Alignment
      • System Integration
      • Uncontrolled Distribution
      • SOP Implementation Gaps
      • SOP Alignment with Validation
      • Change Control Linkage
  • Toggle search form

Gel Manufacturing: SOP for Real-Time Deaeration Monitoring – V 2.0

Posted on By

Gel Manufacturing: SOP for Real-Time Deaeration Monitoring – V 2.0

Standard Operating Procedure for Real-Time Monitoring of Deaeration in Gel Manufacturing


Department Gel Manufacturing
SOP No. SOP/GM/076/2025
Supersedes SOP/GM/076/2022
Page No. Page 1 of 11
Issue Date 02/06/2025
Effective Date 04/06/2025
Review Date 02/06/2026

1. Purpose

This SOP provides a standardized procedure for real-time monitoring of deaeration during the manufacturing of gels to ensure removal of entrapped air and bubbles that could affect product quality, stability, and appearance.

2. Scope

This procedure is applicable to all gel manufacturing processes conducted in the Gel Manufacturing

Department that involve deaeration using vacuum deaerators or equivalent systems.

3. Responsibilities

  • Production Operator: Operates the deaeration system and records parameters.
  • Production Chemist: Verifies effectiveness of deaeration based on real-time data.
  • Quality Assurance: Ensures compliance with SOP and records review.
  • Engineering: Responsible for calibration and maintenance of deaeration sensors.
See also  Gel Manufacturing: SOP for Waste Management of Gel Manufacturing Byproducts - V 2.0

4. Accountability

The Head – Manufacturing shall be accountable for ensuring proper implementation and adherence to this SOP.

5. Procedure

5.1 Pre-Deaeration Checks

  1. Ensure the deaeration equipment is clean, operational, and calibrated.
  2. Check for availability and functionality of pressure gauges, sensors, and control interfaces.
  3. Review the BMR for deaeration specifications such as pressure range, time, and batch-specific instructions.
  4. Ensure the mixing process is completed before initiating deaeration.

5.2 Deaeration Process

  1. Transfer the gel formulation into the vacuum deaerator vessel.
  2. Set the vacuum level as per the BMR (typically -600 to -750 mmHg depending on gel viscosity).
  3. Initiate the deaeration cycle using the control panel.
  4. Monitor foam formation, vacuum level, and deaeration time on the display console.
  5. Record readings at every 5-minute interval or as defined in the BMR.
See also  Gel Manufacturing: SOP for Development of Oil-Based Gels - V 2.0

5.3 Real-Time Monitoring Parameters

Parameter Set Point Acceptable Range Monitoring Tool
Vacuum Pressure -700 mmHg -600 to -750 mmHg Vacuum Gauge
Time Duration 15 minutes ±2 minutes Timer
Air Bubble Observation No bubbles Visual Inspection Transparent View Panel
Noise Level Low humming No rattling Auditory Observation

5.4 Criteria for Acceptable Deaeration

  • No visible air bubbles when gel is dispensed from sampling valve.
  • Steady vacuum pressure maintained throughout cycle.
  • Recorded parameters within specified range.

5.5 Post-Deaeration Activities

  1. End the vacuum cycle and release pressure gradually.
  2. Close valves and transfer gel to bulk storage tanks or directly to filling line as per BMR.
  3. Document final observations and upload real-time sensor data to batch record database.

6. Abbreviations

  • BMR: Batch Manufacturing Record
  • SOP: Standard Operating Procedure
  • QA: Quality Assurance
See also  Gel Manufacturing: SOP for Scaling Up Laboratory Gel Formulations - V 2.0

7. Documents

  1. Deaeration Monitoring Log – Annexure-1
  2. Equipment Usage and Calibration Log – Annexure-2

8. References

  • WHO GMP Guidelines for Pharmaceuticals
  • ICH Q8 – Pharmaceutical Development

9. SOP Version

Version: 2.0

10. Approval Section

Prepared By Checked By Approved By
Signature
Date
Name
Designation Jr. Production Chemist QA Executive Head – Manufacturing
Department Gel Manufacturing Quality Assurance Manufacturing

11. Annexures

Annexure-1: Deaeration Monitoring Log

Date Batch No. Time Vacuum Level (mmHg) Observation (Foam/Bubbles) Remarks Operator Initials
00:00
05:00
10:00
15:00

Annexure-2: Equipment Usage and Calibration Log

Equipment ID Date Used For Batch Calibration Due Status Operator Initials
Calibrated

Revision History

Revision Date Revision No. Change Description Reason Approved By
03/06/2022 1.0 Initial SOP Release New Process QA Head
02/06/2025 2.0 Real-Time Monitoring Added Process Optimization QA Head
Gels V 2.0 Tags:gel excipients SOP, gel extrudability SOP, gel formulation process guidelines, gel formulation safety SOP, gel formulation SOP template, gel homogenization SOP, gel ingredient weighing SOP, gel labeling and documentation SOP, gel microbial contamination SOP, gel packaging SOP, gel viscosity measurement SOP, gel viscosity testing SOP, pharmaceutical gel SOP, quality control SOP gel formulations, SOP for carbopol gel formulation, SOP for gel pH adjustment, SOP for gel spreadability test, stability testing SOP gel, standard operating procedure gel preparation, topical gel manufacturing SOP

Post navigation

Previous Post: Analytical Method Development: Microbial Limit Test Method Development – V 2.0
Next Post: Biosimilars: SOP for Seed Train Validation – V 2.0

Standard Operating Procedures V 1.0

  • Aerosols
  • Analytical Method Development
  • Bioequivalence Bioavailability Study
  • Capsule Formulation
  • Clinical Studies
  • Creams
  • Data Integrity
  • Dental Dosage Forms
  • Drug Discovery
  • Environment, Health and Safety
  • Formulation Development
  • Gels
  • Good Distribution Practice
  • Good Warehousing Practices
  • In-Process Control
  • Injectables
  • Liquid Orals
  • Liposome and Emulsion Formulations
  • Lotions
  • Lyophilized Products
  • Maintenance Dept.
  • Medical Devices
  • Metered-Dose Inhaler
  • Microbiology Testing
  • Nanoparticle Formulation
  • Nasal Spray Formulations
  • Nebulizers
  • Ocular (Eye) Dosage Forms
  • Ointments
  • Otic (Ear) Dosage Forms
  • Pharmacovigilance
  • Powder & Granules
  • Purchase Departments
  • Quality Assurance
  • Quality Control
  • Raw Material Stores
  • Regulatory Affairs
  • Tablet Manufacturing
  • Rectal Dosage Forms
  • Transdermal Patches
  • Vaginal Dosage Forms
  • Validations and Qualifications

Read SOPs in your Language:

 - 
Bengali
 - 
bn
English
 - 
en
Gujarati
 - 
gu
Hindi
 - 
hi
Malayalam
 - 
ml
Marathi
 - 
mr
Punjabi
 - 
pa
Tamil
 - 
ta
Telugu
 - 
te

NEW! Revised SOPs – V 2.0

  • Aerosols V 2.0
  • Analytical Method Development V 2.0
  • API Manufacturing V 2.0
  • BA-BE Studies V 2.0
  • Biosimilars V 2.0
  • Capsules V 2.0
  • Creams V 2.0
  • Elixers V 2.0
  • Gels V 2.0
  • Injectables V 2.0
  • Ointments V 2.0
  • Raw Material Warehouse V 2.0
  • Tablet Manufacturing V2.0

New Publication: A must for All.

Copyright © 2025 SOP Guide for Pharma.

Powered by PressBook WordPress theme

Go to mobile version