Standard Operating Procedure for Manufacturing Thermosensitive Gels in Gel Production
| Department | Gel Manufacturing |
|---|---|
| SOP No. | SOP/GM/189/2025 |
| Supersedes | SOP/GM/189/2022 |
| Page No. | Page 1 of 10 |
| Issue Date | 09/06/2025 |
| Effective Date | 11/06/2025 |
| Review Date | 09/06/2027 |
1. Purpose
This SOP describes the process for manufacturing thermosensitive gels in compliance with GMP standards, ensuring consistency, efficacy, and quality of the final product. Thermosensitive gels undergo a sol-to-gel transition at physiological or specific trigger temperatures.
2. Scope
This procedure applies to the formulation, preparation, filling, and in-process quality control of thermosensitive gels in the Gel Manufacturing Department.
3. Responsibilities
- Production Chemist: Executes the manufacturing process and ensures process parameters are followed.
- QA Executive: Verifies line clearance, sampling, and document compliance.
- R&D/Technology Transfer Team: Provides validated formulation and process specifications.
- Engineering: Ensures temperature control systems
4. Accountability
The Head – Manufacturing is accountable for adherence to this SOP and implementation of thermosensitive gel-specific controls during production.
5. Procedure
5.1 Pre-Manufacturing Preparation
- Receive approved BMR and formulation from R&D/TT department.
- Perform line clearance as per SOP/QA/003/2025 and document in Annexure-1.
- Ensure all equipment (mixing vessels, temperature baths, chillers) are calibrated and clean.
- Verify the HVAC system is operational and temperature settings are within defined range (20°C–25°C ambient).
5.2 Weighing and Dispensing
- Weigh raw materials in a temperature-controlled dispensing area using calibrated balances.
- Dispense thermo-sensitive polymers (e.g., Poloxamer 407, Pluronic F127) at cool ambient temperature (typically 4–8°C).
- Label all containers as per SOP/GM/017/2025 and store under cold conditions until used.
5.3 Preparation of Thermosensitive Gel
- Charge required quantity of purified water into the mixing vessel.
- Cool the water to 4°C using jacketed tank or glycol chiller before adding polymer.
- Gradually add thermosensitive polymer while continuously stirring at low speed to prevent agglomeration.
- Once completely dissolved, maintain at low temperature to prevent gelation.
- Add APIs and excipients (preservatives, pH adjusters) sequentially, maintaining cold conditions.
- Filter the batch through a 0.45 µm or as required filter.
5.4 pH Adjustment and Final Mixing
- Measure pH of gel and adjust to formulation range using chilled acid/base solution.
- Perform final mixing at low shear to ensure homogeneity.
5.5 Filling and Packing
- Use cold-room or temperature-controlled areas for filling to avoid premature gelation.
- Fill into pre-sterilized tubes/jars using positive displacement pumps suitable for viscous materials.
- Seal, label, and over-pack as per product specifications.
5.6 In-process and Finished Product Checks
- Check for viscosity, gelation temperature, homogeneity, and pH as per IP/BP/USP standards.
- Collect retain samples and send for stability studies (Annexure-2).
- Complete batch documentation including cleaning log, calibration status, and yield reconciliation.
6. Abbreviations
- API: Active Pharmaceutical Ingredient
- BMR: Batch Manufacturing Record
- GMP: Good Manufacturing Practice
- HVAC: Heating, Ventilation, and Air Conditioning
- TT: Technology Transfer
7. Documents
- Batch Manufacturing Record – Annexure-1
- Stability Sample Register – Annexure-2
- Equipment Cleaning Log – Annexure-3
- pH Adjustment Record – Annexure-4
- Thermal Profile Monitoring Sheet – Annexure-5
8. References
- ICH Q8: Pharmaceutical Development
- Schedule M: GMP Guidelines for Pharmaceuticals (India)
- USP General Chapter <1059> – Thermosensitive Dosage Forms
9. SOP Version
Version: 2.0
10. Approval Section
| Prepared By | Checked By | Approved By | |
|---|---|---|---|
| Signature | |||
| Date | |||
| Name | |||
| Designation | Jr. Production Chemist | QA Executive | Head – Manufacturing |
| Department | Gel Manufacturing | Quality Assurance | Manufacturing |
11. Annexures
Annexure-1: Batch Manufacturing Record (BMR)
To be completed during each stage of thermosensitive gel production. Includes batch number, yield, ingredient weights, and deviations.
Annexure-2: Stability Sample Register
| Batch No. | Storage Condition | Sampling Date | Tested By | Remarks |
|---|---|---|---|---|
| 25°C/60% RH |
Annexure-3: Equipment Cleaning Log
| Equipment ID | Cleaning Date | Cleaned By | Verified By (QA) |
|---|---|---|---|
Annexure-4: pH Adjustment Record
Record initial and final pH, quantity of acid/base added, solution temperature, and signature.
Annexure-5: Thermal Profile Monitoring Sheet
Monitor and record batch temperature during mixing and filling stages. Include start time, end time, and observations.
Revision History
| Revision Date | Revision No. | Description of Change | Reason | Approved By |
|---|---|---|---|---|
| 28/04/2022 | 1.0 | Initial release | New product line | QA Head |
| 09/06/2025 | 2.0 | Added new annexures and pH adjustment SOP linkage | Process standardization | QA Head |