1. Purpose
The purpose of this Standard Operating Procedure (SOP) is to provide clear and detailed instructions for the preparation of gel base used in the manufacturing of pharmaceutical gels. This ensures batch-to-batch consistency, compliance with GMP guidelines, and readiness for
2. Scope
This SOP applies to all gel base preparations carried out in the Gel Manufacturing Department of the pharmaceutical formulation facility.
3. Responsibilities
- Production Operator: Responsible for executing the gel base preparation as per SOP.
- Production Supervisor: Ensure availability of raw materials and review the process adherence.
- Quality Assurance: Verify the preparation process and review in-process checks and documentation.
4. Accountability
The Head of Manufacturing is accountable for the proper implementation of this SOP. The Quality Assurance Head is responsible for ensuring compliance and documentation control.
5. Procedure
5.1 Preparation Requirements
- Ensure that the area and equipment are cleaned and line clearance is obtained from QA.
- Check and calibrate weighing balances and pH meters before use.
- Verify availability of purified water (as per IP specifications) and all excipients required for gel base formation.
5.2 Dispensing of Ingredients
- Dispense required quantities of ingredients like Carbomer, Hydroxypropyl Methylcellulose (HPMC), Propylene Glycol, etc., as per batch manufacturing record.
- Ensure materials are labeled with status and used within retest or expiry period.
5.3 Gel Base Preparation
- Fill the mixing vessel with a pre-calculated volume of purified water.
- Begin stirring with the slow-speed stirrer and gradually add the gelling agent (e.g., Carbomer) while stirring continuously to avoid lump formation.
- Continue mixing until a homogeneous dispersion is achieved (approximately 20–30 minutes depending on batch size).
- Add humectants like Propylene Glycol or Glycerin while stirring slowly.
5.4 pH Adjustment
- After full dispersion, use a calibrated pH meter to check the pH of the gel base.
- If required, adjust the pH by adding dropwise neutralizing agents such as Triethanolamine or Sodium Hydroxide solution while stirring until the desired pH range (usually 5.0–7.0) is achieved.
5.5 Filtration and Holding
- Filter the gel base using appropriate mesh (e.g., 100 mesh) to remove undissolved particles, if applicable.
- Transfer to a pre-cleaned stainless steel holding vessel fitted with a lid and identification label.
5.6 In-Process Checks
- Appearance: Clear to slightly opalescent.
- pH: As per BMR (5.0–7.0).
- Viscosity: Within specified range using Brookfield Viscometer.
- Documentation of all observations in the BMR.
5.7 Precautions
- Do not add gelling agents too fast to avoid lumping.
- Do not exceed recommended stirring speed to avoid air entrapment.
- Always monitor temperature and pH during preparation.
6. Abbreviations
- API: Active Pharmaceutical Ingredient
- BMR: Batch Manufacturing Record
- GMP: Good Manufacturing Practices
- HPMC: Hydroxypropyl Methylcellulose
7. Documents
- Batch Manufacturing Record – Annexure-1
- Line Clearance Checklist – Annexure-2
- Equipment Calibration Records – Annexure-3
- In-process Check Log – Annexure-4
8. References
- ICH Q7: Good Manufacturing Practice Guide for Active Pharmaceutical Ingredients
- Schedule M – GMP for Pharmaceuticals
- Pharmacopoeia (IP/BP/USP) specifications
9. SOP Version
Version: 2.0
10. Approval Section
| Prepared By | Checked By | Approved By | |
|---|---|---|---|
| Signature | |||
| Date | |||
| Name | |||
| Designation | Jr. Production Chemist | QA Executive | Head – Manufacturing |
| Department | Gel Manufacturing | Quality Assurance | Manufacturing |
11. Annexures
Annexure-1: Batch Manufacturing Record
Includes detailed steps, quantities, and observational fields for gel base preparation.
Annexure-2: Line Clearance Checklist
To be filled before each gel batch preparation to ensure cleanliness and readiness of the area.
Annexure-3: Equipment Calibration Records
Log of last calibration for pH meters, balances, and mixing vessels used in the process.
Annexure-4: In-process Check Log
Document used to record pH, viscosity, appearance, and other control parameters during gel base formation.
Revision History:
| Revision Date | Revision No. | Details | Reason | Approved By |
|---|---|---|---|---|
| 10/04/2022 | 1.0 | Initial release | New SOP introduction | QA Head |
| 02/06/2025 | 2.0 | Added filtration and updated pH adjustment range | Annual review | QA Head |