1. Purpose
To define a procedure for routine environmental monitoring (EM) of classified areas within gel manufacturing facilities to ensure compliance with GMP and minimize risk of contamination to drug products.
2. Scope
This SOP applies to all cleanrooms and controlled areas where gel manufacturing, filling, packaging, or
ancillary operations are carried out.
3. Responsibilities
- Microbiology Analyst: Conducts EM as per the defined schedule and documents results.
- QA Executive: Reviews trends and investigates out-of-limit (OOL) conditions.
- Maintenance Team: Ensures HVAC and HEPA systems are operating within specification.
- Production Officer: Coordinates EM activity with batch production planning.
4. Accountability
Head – Quality Assurance
5. Procedure
5.1 Types of Environmental Monitoring
- Viable Monitoring: Settle plates, contact plates, swabs, and air sampling.
- Non-Viable Monitoring: Particulate monitoring using laser particle counters.
5.2 Locations and Frequency
Identify monitoring locations as per the Environmental Monitoring Plan (EMP), covering:
- Class A/B areas: During operations (e.g., filling, open product exposure).
- Class C/D areas: Before and after cleaning, or during peak activity periods.
5.3 Methods and Equipment
- Settle Plates: Use sterile agar plates exposed for 4 hours at defined locations.
- Contact Plates: Press on surfaces like benches, gloves, and walls.
- Swabs: Collect from irregular surfaces using sterile swab sticks.
- Air Sampling: Use active air samplers (1 m³) near critical points.
- Particle Counters: Calibrated devices used for airborne non-viable particles.
5.4 Sample Handling
- Label all plates with location code, date, and analyst initials.
- Transport samples to microbiology lab in clean containers.
- Incubate viable samples at 30–35°C for 3 days and 20–25°C for 2 days.
See also Gel Manufacturing: SOP for In-process Sampling and Testing during Gel Manufacturing - V 2.0
5.5 Limits and Alert Levels
Follow regulatory specifications (EU GMP, WHO TRS 961) for microbial and particulate counts:
- Grade A: <1 CFU / <3520 particles ≥0.5 µm
- Grade B, C, D: Defined as per facility-specific limits in EMP.
5.6 Deviation and OOL Handling
- Initiate deviation form for OOL events or any EM anomalies.
- Investigate source (e.g., HVAC failure, gowning breach).
- Implement CAPA and record all actions taken.
5.7 Trend Analysis
- Compile monthly trend charts for each monitored location.
- Use trend data to identify recurrent contamination risks or areas for improvement.
5.8 Record Keeping
- Maintain all raw data, EM forms, and summary reports.
- Retain records for a minimum of 5 years or as per regulatory requirement.
6. Abbreviations
- EM: Environmental Monitoring
- OOL: Out of Limit
- HVAC: Heating, Ventilation, and Air Conditioning
- CFU: Colony Forming Units
7. Documents
- Environmental Monitoring Plan – Annexure-1
- EM Sampling Log – Annexure-2
- EM Trend Report Template – Annexure-3
8. References
- EU GMP Annex 1 – Manufacture of Sterile Medicinal Products
- WHO TRS 961 Annex 6 – GMP for HVAC Systems
- ISO 14644: Cleanroom Classification
9. SOP Version
Version: 2.0
10. Approval Section
| Prepared By | Checked By | Approved By | |
|---|---|---|---|
| Signature | |||
| Date | |||
| Name | |||
| Designation | Jr. Production Chemist | QA Executive | Head – Manufacturing |
| Department | Gel Manufacturing | Quality Assurance | Manufacturing |
11. Annexures
Annexure-1: Environmental Monitoring Plan
| Location | Class | Method | Frequency |
|---|---|---|---|
| Filling Room | A/B | Settle Plates, Air Sampling | Daily |
| Compounding Room | C | Swab, Contact Plates | Weekly |
| Corridor | D | Settle Plates | Monthly |
Annexure-2: EM Sampling Log
| Date | Location Code | Method | Result | Analyst Initials | Comments |
|---|---|---|---|---|---|
Annexure-3: EM Trend Report
| Month | Location | CFU Range | Alert Level | Action Taken |
|---|---|---|---|---|
Revision History
| Revision Date | Revision No. | Change Description | Reason | Approved By |
|---|---|---|---|---|
| 20/05/2022 | 1.0 | Initial version | New SOP | QA Head |
| 09/06/2025 | 2.0 | Updated to include particle monitoring and revised annexures | Periodic review | QA Head |