SOP Guide for Pharma

Gel Manufacturing: SOP for Conducting In-Process Testing During Gel Production – V 2.0

Gel Manufacturing: SOP for Conducting In-Process Testing During Gel Production – V 2.0

Standard Operating Procedure for In-Process Quality Testing During Gel Manufacturing


Department Gel Manufacturing
SOP No. SOP/GM/035/2025
Supersedes SOP/GM/035/2022
Page No. Page 1 of 11
Issue Date 02/06/2025
Effective Date 04/06/2025
Review Date 02/06/2026

1. Purpose

The purpose of this Standard Operating Procedure (SOP) is to define the procedure for conducting in-process testing during gel manufacturing to ensure that the product conforms to specified quality standards at various production stages.

2. Scope

This SOP applies to all gel batches manufactured in

the Gel Manufacturing Department and includes procedures for sampling, testing, documentation, and deviation management of in-process controls.

3. Responsibilities

  • Production Chemist: To collect samples and perform preliminary checks as per BMR.
  • Quality Control Analyst: To conduct detailed in-process testing of critical parameters.
  • Quality Assurance Officer: To verify results and authorize continuation of manufacturing.

4. Accountability

The Head – Manufacturing is accountable for ensuring implementation and compliance with this SOP.

5. Procedure

5.1 Sampling Plan

  1. Follow the predefined sampling points outlined in the Batch Manufacturing Record (BMR).
  2. Samples shall be drawn using sanitized sampling devices under laminar airflow conditions.
  3. Label the sample containers with product name, batch number, sampling time, stage, and initials.

5.2 Testing Parameters

The following parameters shall be tested during various manufacturing stages:

  • Appearance: Uniformity, absence of lumps or phase separation.
  • pH: Measured using a calibrated digital pH meter (acceptable range defined in BMR).
  • Viscosity: Checked using Brookfield viscometer at specified RPM and temperature.
  • Homogeneity: Visually inspected and verified using sampling from multiple vessel locations.
  • Weight per mL: Conducted for volume consistency.
  • Temperature: To ensure conditions remain within process-defined range.

5.3 Frequency of In-Process Testing

  1. At pre-mixing stage.
  2. Immediately after phase mixing.
  3. Post pH adjustment.
  4. After homogenization.
  5. Immediately before filling.

5.4 Documentation of Results

  1. Record all in-process testing results in Annexure-1 (In-Process Control Log).
  2. Deviations must be escalated to QA immediately and documented in Annexure-2 (Deviation Log).
  3. Continue to next stage only upon QA approval based on results.

5.5 Acceptance Criteria

Each test result must comply with predefined specifications in the BMR. In case of out-of-specification (OOS) results:

  • Pause production immediately.
  • Initiate investigation as per deviation handling SOP.
  • Document corrective action and retesting procedure.

6. Abbreviations

  • QA: Quality Assurance
  • QC: Quality Control
  • BMR: Batch Manufacturing Record
  • SOP: Standard Operating Procedure

7. Documents

  1. In-Process Control Log – Annexure-1
  2. Deviation Log – Annexure-2
  3. Batch Manufacturing Record (BMR)

8. References

  • Schedule M – Good Manufacturing Practices
  • Internal SOP on Handling Deviations
  • USP Monographs – pH and Viscosity Testing Methods

9. SOP Version

Version: 2.0

10. Approval Section

Prepared By Checked By Approved By
Signature
Date
Name
Designation Jr. Production Chemist QA Executive Head – Manufacturing
Department Gel Manufacturing Quality Assurance Manufacturing

11. Annexures

Annexure-1: In-Process Control Log

Document stage-wise test results with parameters, limits, values, time, and initials.

Annexure-2: Deviation Log

Capture deviations from standard limits, corrective actions, and QA remarks.

Revision History:

Revision Date Revision No. Details Reason Approved By
01/05/2022 1.0 Initial SOP release GMP compliance QA Head
02/06/2025 2.0 Expanded scope to include visual and homogeneity tests Process update QA Head
Exit mobile version