Standard Operating Procedure for Post-Use Cleaning of Homogenizers in Gel Manufacturing
| Department | Gel Manufacturing |
|---|---|
| SOP No. | SOP/GM/052/2025 |
| Supersedes | SOP/GM/052/2022 |
| Page No. | Page 1 of 11 |
| Issue Date | 02/06/2025 |
| Effective Date | 04/06/2025 |
| Review Date | 02/06/2026 |
1. Purpose
To define a standard and validated method for cleaning homogenizers used in gel manufacturing after each use, ensuring effective removal of product residues and microbial contaminants to prevent cross-contamination.
2. Scope
This SOP is applicable to all inline and batch-type homogenizers used during the production of gels
in the Gel Manufacturing area.
3. Responsibilities
- Production Operator: Responsible for execution of the cleaning steps.
- Production Supervisor: To monitor and verify cleaning activities.
- Quality Assurance (QA): To perform cleanliness verification and release equipment for reuse.
4. Accountability
The Head of Production and Head of QA are accountable for ensuring cleaning effectiveness and compliance with this SOP.
5. Procedure
5.1 Pre-Cleaning Preparations
- Turn off power supply to the homogenizer and affix “Under Cleaning” tag.
- Ensure the machine is completely emptied of gel mass before initiating cleaning.
- Don appropriate PPE including gloves, apron, face shield, and safety shoes.
5.2 Cleaning Process
- Disassemble all detachable parts such as blades, stators, shafts, and screens as per equipment manual.
- Rinse all parts with potable water to remove product residues.
- Soak parts in a 2% validated detergent solution for 20–30 minutes to loosen adhering material.
- Scrub surfaces with a nylon brush, ensuring corners, joints, and crevices are cleaned thoroughly.
- Rinse each part with potable water followed by purified water until no foaming is observed.
- Final rinse should be done with Water for Injection (WFI) if equipment is used in sterile production.
- Allow the parts to air dry or use clean lint-free cloth to manually dry them.
- Reassemble the parts after complete drying and ensure all fastenings are tightened appropriately.
5.3 Fixed Inline Homogenizers
- Flush internal circuits using a CIP loop with a validated cleaning solution.
- Allow circulation for 15 minutes followed by a thorough potable and purified water rinse.
- Check the outlet for clarity and absence of residue.
- Dry circuits using sterile compressed air if required.
5.4 Verification and Documentation
- Visual inspection to confirm no residue or discoloration.
- Perform swab test for microbial and chemical residue as per cleaning validation protocol.
- Document cleaning activity in Homogenizer Cleaning Log (Annexure-1).
- Complete the Cleaning Checklist (Annexure-2) and attach swab test report.
6. Abbreviations
- SOP: Standard Operating Procedure
- QA: Quality Assurance
- PPE: Personal Protective Equipment
- CIP: Clean-In-Place
- WFI: Water for Injection
7. Documents
- Homogenizer Cleaning Log – Annexure-1
- Cleaning Checklist – Annexure-2
- Swab Test Report – Annexure-3
8. References
- Manufacturer’s Equipment Manual
- Cleaning Validation Protocol
- GMP Guidelines
9. SOP Version
Version: 2.0
10. Approval Section
| Prepared By | Checked By | Approved By | |
|---|---|---|---|
| Signature | |||
| Date | |||
| Name | |||
| Designation | Jr. Production Chemist | QA Executive | Head – Manufacturing |
| Department | Gel Manufacturing | Quality Assurance | Manufacturing |
11. Annexures
Annexure-1: Homogenizer Cleaning Log
| Date | Equipment ID | Product Name | Type of Cleaning | Performed By | Verified By | Remarks |
|---|---|---|---|---|---|---|
| Batch/Product/Weekly |
Annexure-2: Cleaning Checklist
| Step | Status (Yes/No) | Comments | Checked By |
|---|---|---|---|
| Initial Rinse with Potable Water | |||
| Soaking in Cleaning Agent | |||
| Scrubbing and Brushing | |||
| Final WFI Rinse | |||
| Drying Completed |
Annexure-3: Swab Test Report
| Equipment ID | Date | Swab Location | Test Type | Result | Analyst | Approved By |
|---|---|---|---|---|---|---|
| Rotor/Stator/Outlet | Microbial/Chemical |
Revision History
| Revision Date | Revision No. | Details | Reason | Approved By |
|---|---|---|---|---|
| 01/06/2022 | 1.0 | Initial issue | New SOP | QA Head |
| 02/06/2025 | 2.0 | Updated with CIP-specific instructions and annexure formats | Periodic Review | QA Head |