Elixir Department: SOP for Test for Suspended Particles – V 2.0

Elixir Department: SOP for Test for Suspended Particles – V 2.0

Standard Operating Procedure for Testing Suspended Particles in Elixir Formulations

Department Elixir Department
SOP No. SOP/ELX/220/2025
Supersedes SOP/ELX/220/2022
Page No. Page 1 of 8
Issue Date 11/04/2025
Effective Date 15/04/2025
Review Date 11/04/2026

1. Purpose

To define a standardized procedure for detecting and quantifying visible and sub-visible suspended particles in elixir formulations to ensure compliance with pharmacopoeial standards and product quality.

2. Scope

This SOP applies to all batches of elixirs produced and tested by the Quality Control Department for the presence of suspended particulate matter as part of finished product testing.

3. Responsibilities

  • QC Analyst:
    • Perform the test using visual and instrumental methods.
    • Document findings in logbooks and report deviations.
  • QC Supervisor:
    • Verify results and ensure the test is performed under controlled environmental conditions.
  • QA Officer:
    • Review the report and approve test results for batch release.

4. Accountability

The QC Head is accountable for the execution and evaluation of this test. The QA Head ensures adherence to specifications and regulatory compliance.

5. Procedure

5.1 Sample Preparation

  1. Take a
representative 25–50 mL sample of the elixir in a clean, transparent, colorless glass container.
  • Ensure the sample is well mixed and free from bubbles or froth.
  • Allow the sample to rest for 2–3 minutes before evaluation.
  • 5.2 Visual Inspection

    1. Perform the test under uniform illumination (approx. 1000 lux) in a clean, dust-free area.
    2. Place the sample against a black and white background and observe at eye level.
    3. Slowly rotate the sample and examine for:
      • Floating or suspended particles
      • Settled precipitate
      • Crystals, fibers, or other visible contaminants
    4. Record findings and classify the sample as:
      • Clear: No visible suspended matter
      • Slightly Suspended: Few non-uniform particles visible
      • Suspended: Definite visible particulate matter

    5.3 Optional Instrumental Method (If Applicable)

    1. Use a particle counter or turbidimeter if method validation supports it.
    2. Record particle size distribution and count (e.g., particles >10 µm and >25 µm).
    3. Follow USP <788> or similar method for interpretation if applied.

    5.4 Acceptance Criteria

    1. No visible suspended matter should be present.
    2. If slight particles are seen, ensure justification exists in product specification and verify absence of microbial/fungal growth.
    3. Any unexpected precipitate, sedimentation, or contamination shall lead to batch investigation.

    5.5 Documentation

    1. Record observations in the Suspended Particles Inspection Logbook (Annexure-1).
    2. Attach any images or instrument reports (if used) to the BMR.

    6. Abbreviations

    • SOP: Standard Operating Procedure
    • QC: Quality Control
    • QA: Quality Assurance
    • BMR: Batch Manufacturing Record
    • µm: Micrometer

    7. Documents

    1. Suspended Particles Inspection Logbook (Annexure-1)
    2. Instrument Calibration Certificates (if applicable)
    3. Batch Manufacturing Record (BMR)

    8. References

    • USP General Chapter <790> – Visible Particulates in Injections (adapted for orals)
    • USP General Chapter <788> – Particulate Matter in Injections (for particle size count)
    • 21 CFR Part 211.160 – Laboratory Controls

    9. SOP Version

    Version: 2.0

    10. Approval Section

    Prepared By Checked By Approved By
    Signature
    Date
    Name
    Designation
    Department

    11. Annexures

    Annexure-1: Suspended Particles Inspection Logbook

    Date Batch No. Observation Classification Tested By Verified By
    11/04/2025 ELX-0425-038 No particles observed Clear Rajesh Kumar Sunita Reddy

    Revision History:

    Revision Date Revision No. Revision Details Reason for Revision Approved By
    01/01/2024 1.0 Initial Release New SOP QA Head
    11/04/2025 2.0 Included optional particle size testing Method Enhancement QA Head