Standard Operating Procedure for Solubility Testing at Intermediate Stages in Elixir Manufacturing
| Department | Elixir Department |
|---|---|
| SOP No. | SOP/ELX/197/2025 |
| Supersedes | SOP/ELX/197/2022 |
| Page No. | Page 1 of 8 |
| Issue Date | 11/04/2025 |
| Effective Date | 15/04/2025 |
| Review Date | 11/04/2026 |
1. Purpose
To define a standardized procedure for performing solubility testing of active ingredients and excipients at intermediate stages of elixir manufacturing to ensure complete dissolution and avoid precipitation during further processing.
2. Scope
This SOP applies to all elixir batches that require confirmation of solubility of active ingredients and selected excipients after their addition during processing, and prior to bulk completion.
3. Responsibilities
- Production Operator:
- Collect samples for solubility testing as per stage-wise instructions.
- QC Analyst:
- Perform solubility checks using visual inspection, centrifugation, or filtration, and document findings.
- QA Officer:
- Ensure compliance with sampling and testing procedures and review results.
4. Accountability
The Production Head is accountable for correct sampling. QC Head is responsible for test accuracy. QA is accountable for documentation and compliance verification.
5. Procedure
5.1 Sampling
for Solubility Testing
- Sample after complete addition and mixing of the API or excipient in the manufacturing tank.
- Collect 50 mL of the sample in a clean, dry, transparent glass vial.
- Label with product name, batch number, stage, date, and “Solubility Sample.”
- Transport the sample to the QC lab immediately to avoid temperature-induced solubility shifts.
5.2 Testing Procedure
- Visual Inspection: Hold the vial against white and black backgrounds and observe for undissolved particles, turbidity, or haze.
- Filtration Method:
- Filter 10 mL of the sample through a 0.45 µm filter paper.
- Check for residue on the filter. No visible residue indicates complete solubility.
- Centrifugation Method:
- Centrifuge 10 mL of the sample at 3000 rpm for 10 minutes.
- Check for sediment or phase separation.
5.3 Acceptance Criteria
- The solution must appear clear or as per product specifications.
- No visible undissolved particles, sediments, or phase separation should be observed.
- If undissolved matter is present, notify Production and QA for reprocessing or mixing extension.
5.4 Corrective Actions for Non-Conformance
- Hold the batch and inform QA.
- Repeat mixing and re-test solubility.
- If solubility is not achieved after reprocessing, escalate to product development and initiate deviation handling.
5.5 Documentation
- Record test results in the Solubility Testing Logbook (Annexure-1).
- Include batch details, test method used, observation, interpretation, and analyst initials.
- Attach supporting evidence such as filter papers (if applicable) to the batch documentation file.
6. Abbreviations
- SOP: Standard Operating Procedure
- QC: Quality Control
- QA: Quality Assurance
- API: Active Pharmaceutical Ingredient
- RPM: Revolutions Per Minute
7. Documents
- Solubility Testing Logbook (Annexure-1)
- Batch Manufacturing Record (BMR)
- Analytical Method Sheet
8. References
- ICH Q6A – Specifications: Test Procedures and Acceptance Criteria
- WHO TRS 986 – GMP for Pharmaceuticals
- 21 CFR Part 211 – Subpart I: Laboratory Controls
9. SOP Version
Version: 2.0
10. Approval Section
| Prepared By | Checked By | Approved By | |
|---|---|---|---|
| Signature | |||
| Date | |||
| Name | |||
| Designation | |||
| Department |
11. Annexures
Annexure-1: Solubility Testing Logbook
| Date | Batch No. | Stage | Test Method | Observation | Result | Analyst | QA Verified |
|---|---|---|---|---|---|---|---|
| 11/04/2025 | ELX-0425-016 | Post-API Addition | Filtration | No Residue on Filter | Pass | Rajesh Kumar | Sunita Reddy |
Revision History:
| Revision Date | Revision No. | Revision Details | Reason for Revision | Approved By |
|---|---|---|---|---|
| 01/01/2024 | 1.0 | Initial Release | New SOP | QA Head |
| 11/04/2025 | 2.0 | Added centrifugation method and corrective action flow | Process Enhancement | QA Head |