Standard Operating Procedure for Use of Single-Use Bioreactor Systems in Biosimilar Manufacturing
| Department | Biosimilars |
|---|---|
| SOP No. | SOP/BS/100/2025 |
| Supersedes | SOP/BS/100/2022 |
| Page No. | Page 1 of 13 |
| Issue Date | 04/05/2025 |
| Effective Date | 06/05/2025 |
| Review Date | 04/05/2026 |
1. Purpose
To define the standard procedure for the preparation, operation, and disposal of single-use bioreactor (SUB) systems used in biosimilar manufacturing, ensuring aseptic processing and operational consistency.
2. Scope
This SOP applies to all single-use bioreactors ranging from 50L to 2000L capacity used in upstream processing within the biosimilars facility.
3. Responsibilities
- Production: Set up, monitor, and dispose of SUB systems per batch requirement.
- Engineering: Verify equipment integrity, calibrate load cells, and support automation interfaces.
- QA: Ensure SUB components are qualified and that batch documentation complies with GMP standards.
4. Accountability
The Manufacturing Head is accountable for ensuring proper utilization and documentation of SUB systems as per validated procedures.
5. Procedure
5.1 Receipt and Inspection of SUB Components
- Receive pre-sterilized bioreactor bag assemblies with gamma irradiation certification (Annexure-1).
- Verify integrity of ports, sensors, weld lines, and bag labeling.
- Check irradiation indicator color change and record batch number.
5.2 Assembly and Installation
- Install the bag into the SUB vessel and connect sparger, dip tube, pH/DO probes, and sampling lines.
- Use aseptic connections (e.g., AseptiQuik) for media, feed, and vent lines.
- Secure probes and tighten clamps to prevent leaks or disconnections.
5.3 System Integrity Testing
- Conduct leak test by filling bag with 10–20 L sterile air or nitrogen and applying pressure of 0.2 bar.
- Monitor for 10 minutes and confirm no pressure drop.
- Record test in Annexure-2: SUB Integrity Log.
5.4 Media Charging and Inoculation
- Transfer sterile media through aseptic transfer line using peristaltic pump.
- Confirm temperature, pH, and DO sensors are calibrated and functional.
- Inoculate culture using sterile connections and begin agitation and aeration based on protocol.
5.5 Operation Monitoring
- Monitor bioreactor parameters via control system (e.g., DeltaV, BioPAT).
- Record agitation speed, pH, DO, VCD, and temperature every 4 hours or as per BMR.
- Document all interventions in Annexure-3: Bioreactor Operation Log.
5.6 Harvest and Disposal
- Transfer culture broth to harvest tank via sterile connections.
- Drain and seal used SUB bag in biohazard bag and place in designated disposal bin.
- Sanitize SUB vessel with 70% IPA before storage.
6. Abbreviations
- SUB: Single-Use Bioreactor
- BMR: Batch Manufacturing Record
- IPA: Isopropyl Alcohol
- QA: Quality Assurance
7. Documents
- Gamma Irradiation Certificate – Annexure-1
- SUB Integrity Log – Annexure-2
- Bioreactor Operation Log – Annexure-3
8. References
- FDA Guidance for Industry – Single-Use Technology in Biopharmaceutical Manufacturing (2021)
- ICH Q9 – Quality Risk Management
9. SOP Version
Version: 2.0
10. Approval Section
| Prepared By | Checked By | Approved By | |
|---|---|---|---|
| Signature | |||
| Date | |||
| Name | |||
| Designation | |||
| Department |
11. Annexures
Annexure-1: Gamma Irradiation Certificate
| Bag ID | Lot No. | Irradiation Date | Indicator Color | Checked By |
|---|---|---|---|---|
| SUB-100L-21 | GIR-789 | 01/05/2025 | Orange to Red | Ajay Verma |
Annexure-2: SUB Integrity Log
| Date | SUB ID | Test Pressure (bar) | Hold Time | Result | Performed By |
|---|---|---|---|---|---|
| 04/05/2025 | SUB-200L-35 | 0.2 | 10 min | Pass | Rajesh Kumar |
Annexure-3: Bioreactor Operation Log
| Time | pH | DO (%) | Temperature (°C) | Agitation (rpm) | Operator |
|---|---|---|---|---|---|
| 08:00 | 7.1 | 40 | 37.0 | 120 | Sunita Reddy |
Revision History:
| Revision Date | Revision No. | Revision Details | Reason for Revision | Approved By |
|---|---|---|---|---|
| 04/05/2025 | 2.0 | Included leak test procedure and annexures for irradiation certificate and logs | Periodic review and alignment with FDA guidelines |