SOP Guide for Pharma

Biosimilars: SOP for Reporting Critical Deviations to QA – V 2.0


Biosimilars: SOP for Reporting Critical Deviations to QA – V 2.0


Standard Operating Procedure for Reporting Critical Deviations to QA in Biosimilar Manufacturing

Department Biosimilars
SOP No. SOP/BS/142/2025
Supersedes SOP/BS/142/2022
Page No. Page 1 of 9
Issue Date 04/05/2025
Effective Date 06/05/2025
Review Date 04/05/2026

1. Purpose

To define the procedure for promptly identifying, recording, assessing, and reporting critical deviations to the Quality Assurance (QA) department in biosimilar manufacturing operations, ensuring compliance with GMP and minimizing product quality risks.

2. Scope

This SOP applies to all departments involved in GMP operations including production, QC, warehouse, and engineering within the biosimilar manufacturing facility where critical deviations may impact product safety, efficacy, or regulatory compliance.

3. Responsibilities

  • Departmental Heads: Ensure all deviations are escalated and reported as per defined timelines.
  • QA: Investigate and evaluate the criticality of deviations, approve the investigation reports, and determine disposition.
  • All Employees: Immediately inform supervisors and initiate deviation documentation upon observation.

4. Accountability

The QA Head is accountable for ensuring that all critical deviations are thoroughly investigated, documented, and reported to regulatory bodies as needed.

5. Procedure

5.1 Identification of Critical Deviations

  1. Any unexpected event or non-compliance that may affect product quality, data integrity, or regulatory status must be flagged as a potential critical deviation.
  2. Examples include:
    • Use of expired materials
    • Unplanned equipment failure during manufacturing
    • Missed or incorrect process parameters (e.g., temperature, pH)
    • Data falsification or manipulation
    • Environmental excursions in cleanroom conditions

5.2 Immediate Actions

  1. Pause the affected operation, isolate impacted material (if applicable), and label as “On Hold.”
  2. Notify the Department Head and QA within 30 minutes of detection.
  3. Complete Annexure-1: Deviation Reporting Form with preliminary details.

5.3 QA Assessment and Investigation

  1. QA shall:
    • Determine criticality and classify deviation as Critical, Major, or Minor.
    • Initiate root cause analysis using tools like 5 Whys or Fishbone diagram.
    • Define and assign Corrective and Preventive Actions (CAPA).
  2. Complete Annexure-2: Deviation Investigation Report.

5.4 Review and Closure

  1. QA shall review effectiveness of CAPA before closing deviation.
  2. Deviation must be closed within 30 calendar days unless extension is approved.
  3. Final disposition must be recorded in Annexure-3: Deviation Closure Record.

5.5 Regulatory Reporting

  1. Report deviations affecting marketed product, critical quality attributes, or patient safety to applicable regulatory bodies (e.g., CDSCO, EMA, USFDA).
  2. Maintain a log of reported deviations in Annexure-4: Regulatory Notification Log.

6. Abbreviations

  • QA: Quality Assurance
  • CAPA: Corrective and Preventive Action
  • GMP: Good Manufacturing Practice
  • CDSCO: Central Drugs Standard Control Organization

7. Documents

  1. Deviation Reporting Form – Annexure-1
  2. Deviation Investigation Report – Annexure-2
  3. Deviation Closure Record – Annexure-3
  4. Regulatory Notification Log – Annexure-4

8. References

  • ICH Q10 – Pharmaceutical Quality System
  • WHO TRS 986 – GMP for Biological Products
  • FDA Guidance on Quality Systems Approach to Pharmaceutical CGMP Regulations

9. SOP Version

Version: 2.0

10. Approval Section

Prepared By Checked By Approved By
Signature
Date
Name
Designation
Department

11. Annexures

Annexure-1: Deviation Reporting Form

Date Reported By Department Deviation Description Immediate Action
04/05/2025 Ajay Verma Production Temperature spike in bioreactor Process stopped

Annexure-2: Deviation Investigation Report

Deviation ID Root Cause CAPA Investigator Date
DEV/BS/042 Controller fault Recalibration and SOP update Sunita Reddy 05/05/2025

Annexure-3: Deviation Closure Record

Deviation ID CAPA Verified Closed On QA Reviewer
DEV/BS/042 Yes 06/05/2025 QA Head

Annexure-4: Regulatory Notification Log

Deviation ID Agency Date Notified Reference No. Status
DEV/BS/042 CDSCO 06/05/2025 CD-INT/2025/042 Closed

Revision History:

Revision Date Revision No. Revision Details Reason for Revision Approved By
04/05/2025 2.0 Added regulatory reporting annexure Compliance Enhancement
Exit mobile version