Biosimilars: SOP for Protein A Affinity Chromatography Setup – V 2.0
Standard Operating Procedure for Protein A Affinity Chromatography Setup in Biosimilar Manufacturing
| Department |
Biosimilars |
| SOP No. |
SOP/BS/154/2025 |
| Supersedes |
SOP/BS/154/2022 |
| Page No. |
Page 1 of 10 |
| Issue Date |
04/05/2025 |
| Effective Date |
06/05/2025 |
| Review Date |
04/05/2026 |
1. Purpose
To define the GMP-compliant procedure for setting up Protein A affinity chromatography columns used in the capture and purification of monoclonal antibodies in biosimilar manufacturing processes.
2. Scope
This SOP applies to all single-use or reusable Protein A chromatography columns used in downstream processing (DSP) of biosimilar monoclonal antibodies at manufacturing scale.
3. Responsibilities
- Production: Perform setup, equilibration, and buffer line connections.
- QA: Verify batch record entries, review system readiness, and approve initiation of chromatography.
- Engineering: Maintain chromatography skid calibration and support troubleshooting.
4. Accountability
The Downstream Process Lead is accountable for ensuring that Protein A chromatography setup is performed as per validated process and recorded in GMP batch documentation.
5. Procedure
5.1 Pre-Setup Checks
- Verify column ID, resin batch number, cleaning status, and integrity label.
- Confirm column packing status (pre-packed vs in-house packed).
- Record all pre-use checks in Annexure-1: Chromatography Setup Checklist.
5.2 Buffer Preparation and Line Assignment
- Prepare and label the following buffers:
- Equilibration Buffer (e.g., PBS, pH 7.4)
- Binding Buffer
- Elution Buffer (e.g., Glycine-HCl, pH 3.0)
- Regeneration Buffer (e.g., 0.1 M NaOH)
- Storage Buffer (e.g., 20% ethanol)
- Assign buffer lines using color-coded, sanitized tubing.
- Prime lines to remove air bubbles and avoid spiking during gradient runs.
5.3 Column Connection
- Connect the column inlet and outlet to the skid using aseptic, leak-free connectors.
- Ensure correct flow direction and backpressure tolerance (refer OEM specs).
- Secure the column using appropriate clamp or housing base.
5.4 System Sanitization and Flow Path Integrity
- Flush the column and associated skid path with 0.1 M NaOH for 20 minutes (if required).
- Rinse with WFI until pH reaches 7.0 ± 0.2 and conductivity is below 10 µS/cm.
- Check for leaks and record line integrity in Annexure-2: Flow Path Check Log.
5.5 Equilibration
- Pass equilibration buffer at 100–150 cm/hr flow rate for 5–10 column volumes.
- Monitor UV baseline stability and pH to ensure readiness for sample loading.
5.6 Documentation
- Record:
- Column ID and resin lot
- Buffer names, lot numbers, and pH
- Flow rate and pressure
- Temperature (if controlled)
- Attach skid-generated chromatogram to batch record.
6. Abbreviations
- PBS: Phosphate Buffered Saline
- DSP: Downstream Processing
- OEM: Original Equipment Manufacturer
- WFI: Water for Injection
7. Documents
- Chromatography Setup Checklist – Annexure-1
- Flow Path Check Log – Annexure-2
8. References
- WHO TRS 999 – Guidelines on Biotherapeutic Products
- ICH Q8 – Pharmaceutical Development
- OEM Manual – Cytiva/GE Healthcare Protein A Columns
9. SOP Version
Version: 2.0
10. Approval Section
|
Prepared By |
Checked By |
Approved By |
| Signature |
|
|
|
| Date |
|
|
|
| Name |
|
|
|
| Designation |
|
|
|
| Department |
|
|
|
11. Annexures
Annexure-1: Chromatography Setup Checklist
| Date |
Column ID |
Resin Batch |
Pre-Use Sanitization |
Leak Check |
Operator |
| 04/05/2025 |
PA-01 |
GE-RBT-2201 |
Yes |
Pass |
Ajay Verma |
Annexure-2: Flow Path Check Log
| Date |
Skid ID |
Buffer Line |
Rinse pH |
Conductivity |
Status |
Verified By |
| 04/05/2025 |
CHM-120 |
A-EQ |
7.1 |
8.5 µS/cm |
OK |
Sunita Reddy |
Revision History:
| Revision Date |
Revision No. |
Revision Details |
Reason for Revision |
Approved By |
| 04/05/2025 |
2.0 |
Updated sanitization and resin traceability steps |
Process harmonization |
|