Biosimilars: SOP for Nutrient Feed Preparation and Addition in Bioreactor Operations – V 2.0
Standard Operating Procedure for Nutrient Feed Preparation and Addition in Bioreactor Operations for Biosimilars
| Department |
Biosimilars |
| SOP No. |
SOP/BS/076/2025 |
| Supersedes |
SOP/BS/076/2022 |
| Page No. |
Page 1 of 12 |
| Issue Date |
04/05/2025 |
| Effective Date |
06/05/2025 |
| Review Date |
04/05/2026 |
1. Purpose
To define the standardized procedure for the preparation, filtration, labeling, storage, and controlled aseptic addition of nutrient feeds into bioreactors during biosimilar upstream processing.
2. Scope
This SOP applies to all types of nutrient feeds (e.g., glucose, amino acids, lipids, trace elements) prepared for use in fed-batch and perfusion bioreactor processes in the biosimilar production facility.
3. Responsibilities
- Process Operators: Prepare, filter, and aseptically transfer nutrient feeds as per instructions.
- Formulation Chemist: Verify feed formulations and ensure raw material identity and quantity.
- QA Personnel: Approve feed preparation records and cross-check batch details.
4. Accountability
The Head of Upstream Manufacturing is accountable for ensuring nutrient feeds are prepared and added correctly, without compromising sterility or cell culture performance.
5. Procedure
5.1 Raw Material Verification
- Verify all raw materials against the Bill of Materials (BoM) and ensure valid CoA is available.
- Ensure containers are labeled with item code, batch number, and expiry date.
5.2 Feed Preparation
- Transfer materials into the formulation area under laminar airflow.
- Use calibrated balances to weigh materials with ±0.1 g accuracy (Annexure-1).
- Dissolve powders in WFI or process-grade water with magnetic stirring or overhead mixer.
- Adjust pH (if required) and document final pH before filtration.
5.3 Sterile Filtration
- Filter solution through a 0.22 µm PES or PVDF sterile-grade filter into a sterile, labeled container.
- Conduct filter integrity test pre- and post-use (Annexure-2).
5.4 Labeling and Storage
- Label containers with Feed Type, Batch No., Preparation Date, Expiry Date, Volume, and Storage Conditions (Annexure-3).
- Store feed solutions between 2–8°C for up to 7 days or as validated.
5.5 Feed Addition to Bioreactor
- Bring feed solution to ambient temperature before use.
- Disinfect container surface using 70% IPA and connect aseptically to bioreactor via sterile tubing or port.
- Use peristaltic pump or gravity flow to add feed; avoid contamination or backflow.
- Record feed volume, addition time, and operator initials (Annexure-4).
6. Abbreviations
- WFI: Water for Injection
- IPA: Isopropyl Alcohol
- PES: Polyethersulfone
- PVDF: Polyvinylidene Difluoride
7. Documents
- Weighing and Formulation Sheet – Annexure-1
- Filter Integrity Log – Annexure-2
- Feed Label Template – Annexure-3
- Feed Addition Record – Annexure-4
8. References
- ICH Q7 – GMP for Active Pharmaceutical Ingredients
- WHO TRS 1025 – Biomanufacturing Guidelines
- USP <797> – Sterile Preparations
9. SOP Version
Version: 2.0
10. Approval Section
|
Prepared By |
Checked By |
Approved By |
| Signature |
|
|
|
| Date |
|
|
|
| Name |
|
|
|
| Designation |
|
|
|
| Department |
|
|
|
11. Annexures
Annexure-1: Weighing and Formulation Sheet
| Material |
Required Qty (g) |
Actual Qty (g) |
Weighed By |
Date |
| Glucose Monohydrate |
100 |
100.01 |
Rajesh Kumar |
04/05/2025 |
Annexure-2: Filter Integrity Log
| Filter ID |
Pre-Test Result |
Post-Test Result |
Passed? |
Checked By |
| FLT-076-01 |
Pass |
Pass |
Yes |
Sunita Reddy |
Annexure-3: Feed Label Template
| Feed Type |
Batch No. |
Volume |
Prep Date |
Expiry |
Storage |
| Feed B |
NF-BIO-076-01 |
3L |
04/05/2025 |
11/05/2025 |
2–8°C |
Annexure-4: Feed Addition Record
| Date |
Time |
Volume Added (mL) |
Operator Initials |
Remarks |
| 04/05/2025 |
14:00 |
150 |
RK |
Initial bolus feed |
Revision History:
| Revision Date |
Revision No. |
Revision Details |
Reason for Revision |
Approved By |
| 04/05/2025 |
2.0 |
Added filtration and labeling procedures |
GMP alignment |
|