Standard Operating Procedure for In-Process Sampling Procedures in Bioreactor Operations for Biosimilars
| Department | Biosimilars |
|---|---|
| SOP No. | SOP/BS/078/2025 |
| Supersedes | SOP/BS/078/2022 |
| Page No. | Page 1 of 11 |
| Issue Date | 04/05/2025 |
| Effective Date | 06/05/2025 |
| Review Date | 04/05/2026 |
1. Purpose
To define the standardized method for aseptic in-process sampling from bioreactors used in biosimilar production. This SOP ensures representative, contaminant-free samples for analysis of critical process parameters.
2. Scope
This SOP applies to all stainless steel and single-use bioreactor systems used in upstream biosimilar manufacturing for sampling culture media, cells, metabolites, and gases.
3. Responsibilities
- Bioprocess Technicians: Perform in-process sampling and record data.
- QC Analysts: Analyze collected samples for cell count, viability, pH, metabolites, etc.
- QA Officer: Verify logbook entries and confirm sampling frequencies.
4. Accountability
The Upstream Production Manager is accountable for ensuring in-process sampling is performed aseptically and results are promptly reviewed.
5. Procedure
5.1 Sampling Frequency
- Follow the sampling schedule as per the approved Batch Manufacturing Record (BMR).
- Typical sampling intervals:
- Every 12 hours during the batch phase
- Every 8 hours during the feeding phase
- Every 4 hours near harvest phase
5.2 Preparation
- Ensure all sampling accessories are sterile (syringes, sample bags, tubes).
- Wipe sampling ports with 70% IPA and ensure sterile gloves and gowning.
- Label sample containers with:
- Batch No.
- Date and Time
- Sample Type
5.3 Sampling Technique
- Connect sampling line or septum port to a sterile syringe or sampling valve.
- Discard the first 2–5 mL to remove stagnant fluid (flush step).
- Collect the required volume (typically 10–20 mL) without introducing air bubbles.
- Seal sample container immediately and transfer to QC or store at 2–8°C until analysis.
5.4 Post Sampling
- Disinfect sampling port again with 70% IPA and close securely.
- Dispose of used syringes and gloves as per biohazard SOPs.
- Record the sampling details in the Bioreactor Sampling Log (Annexure-1).
5.5 Sample Handling and Transfer
- Transport samples in designated clean containers to QC within 30 minutes of collection.
- Log handover with time and recipient signature in Sample Transfer Log (Annexure-2).
6. Abbreviations
- BMR: Batch Manufacturing Record
- QC: Quality Control
- IPA: Isopropyl Alcohol
7. Documents
- Bioreactor Sampling Log – Annexure-1
- Sample Transfer Log – Annexure-2
8. References
- ICH Q9 – Quality Risk Management
- WHO TRS 999 – GMP for Biological Products
9. SOP Version
Version: 2.0
10. Approval Section
| Prepared By | Checked By | Approved By | |
|---|---|---|---|
| Signature | |||
| Date | |||
| Name | |||
| Designation | |||
| Department |
11. Annexures
Annexure-1: Bioreactor Sampling Log
| Date | Time | Batch No. | Sample Type | Volume (mL) | Collected By | Remarks |
|---|---|---|---|---|---|---|
| 04/05/2025 | 08:00 | BS-BR-078 | Viability | 15 | Rajesh Kumar | Normal |
Annexure-2: Sample Transfer Log
| Date | Time | Sample ID | Transferred To | Signature |
|---|---|---|---|---|
| 04/05/2025 | 08:15 | BS-078-08V | Sunita Reddy | SR |
Revision History:
| Revision Date | Revision No. | Revision Details | Reason for Revision | Approved By |
|---|---|---|---|---|
| 04/05/2025 | 2.0 | Updated sample handling and transfer timelines | GMP Compliance |