Biosimilars: SOP for Elution and Regeneration of Protein A Column – V 2.0
Standard Operating Procedure for Elution and Regeneration of Protein A Column in Biosimilar Manufacturing
| Department |
Biosimilars |
| SOP No. |
SOP/BS/156/2025 |
| Supersedes |
SOP/BS/156/2022 |
| Page No. |
Page 1 of 10 |
| Issue Date |
04/05/2025 |
| Effective Date |
06/05/2025 |
| Review Date |
04/05/2026 |
1. Purpose
To define the procedure for elution of bound monoclonal antibodies from Protein A affinity chromatography columns and subsequent regeneration of the column for reuse in biosimilar downstream processing.
2. Scope
This SOP is applicable to all Protein A columns used in the purification of monoclonal antibodies (mAbs) in biosimilar manufacturing across single-use or reusable chromatography systems.
3. Responsibilities
- Production: Execute elution and regeneration procedures and monitor critical parameters.
- QA: Verify and review elution recovery logs and resin regeneration data.
- Engineering: Maintain and calibrate chromatography skids and monitor pressure profiles.
4. Accountability
The Head of Downstream Processing is accountable for ensuring successful product recovery and column reuse under validated and GMP-compliant conditions.
5. Procedure
5.1 Elution of Monoclonal Antibody
- Ensure equilibration and product loading are completed as per SOP/BS/155/2025.
- Prepare Elution Buffer (e.g., 0.1 M Glycine-HCl, pH 2.8–3.0).
- Connect the elution buffer line to the chromatography skid.
- Set the elution parameters:
- Flow rate: 80–100 cm/hr
- Volume: 3–5 column volumes (CV) or as validated
- Monitor UV at 280 nm. Start elution collection when UV absorbance exceeds 0.05 AU.
- Collect elution peak in pre-labeled sterile bags or bottles.
- Neutralize pooled elution fractions immediately using neutralization buffer (e.g., 1 M Tris-HCl, pH 8.0).
- Record the elution profile in Annexure-1: Elution Log Sheet and attach chromatogram printouts.
5.2 Post-Elution Wash
- Flush column with equilibration buffer until baseline UV is restored.
- This step removes loosely bound contaminants before regeneration.
5.3 Column Regeneration
- Prepare Regeneration Buffer (e.g., 0.1–0.5 M NaOH).
- Pass regeneration buffer at 100–150 cm/hr for 3–5 CV or for 20 minutes, whichever is longer.
- Allow static contact (soaking) for 15–30 minutes if specified in the resin manufacturer’s protocol.
- Rinse with WFI or storage buffer until pH stabilizes at 6.8–7.2.
- Record resin contact time and buffer volumes in Annexure-2: Regeneration Record.
5.4 Resin Storage (Reusable Columns)
- Store resin in appropriate storage solution (e.g., 20% ethanol) at 2–8°C if not reused immediately.
- Label storage status clearly on column tag and log storage start time.
5.5 Disposal (Single-Use Columns)
- Disconnect and discard single-use columns per biohazard disposal SOPs.
- Document lot traceability in Annexure-3: Column Usage and Disposal Log.
6. Abbreviations
- mAb: Monoclonal Antibody
- CV: Column Volume
- NaOH: Sodium Hydroxide
- WFI: Water for Injection
7. Documents
- Elution Log Sheet – Annexure-1
- Regeneration Record – Annexure-2
- Column Usage and Disposal Log – Annexure-3
8. References
- WHO TRS 999 – Guidelines on Biotherapeutic Products
- ICH Q8 – Pharmaceutical Development
- OEM Resin Manual – Cytiva MabSelect, Repligen Amsphere
9. SOP Version
Version: 2.0
10. Approval Section
|
Prepared By |
Checked By |
Approved By |
| Signature |
|
|
|
| Date |
|
|
|
| Name |
|
|
|
| Designation |
|
|
|
| Department |
|
|
|
11. Annexures
Annexure-1: Elution Log Sheet
| Date |
Batch No. |
Elution Buffer |
Start Time |
End Time |
Volume Collected |
Operator |
| 04/05/2025 |
BS-DP-084 |
Gly-HCl, pH 3.0 |
11:00 |
11:45 |
2.2 L |
Ajay Verma |
Annexure-2: Regeneration Record
| Date |
Column ID |
NaOH Conc. |
Contact Time |
Rinse Volume |
Final pH |
Performed By |
| 04/05/2025 |
PA-01 |
0.5 M |
20 min |
8 L |
7.1 |
Sunita Reddy |
Annexure-3: Column Usage and Disposal Log
| Column ID |
Used In Batch |
No. of Cycles |
Storage/Disposal |
Action Date |
Handled By |
| PA-SU-202 |
BS-DP-084 |
1 |
Disposed |
04/05/2025 |
QA Officer |
Revision History:
| Revision Date |
Revision No. |
Revision Details |
Reason for Revision |
Approved By |
| 04/05/2025 |
2.0 |
Updated resin storage and disposal steps for single-use columns |
Compliance update |
|