Biosimilars: SOP for Cleaning and Decontamination of Cell Culture Areas – V 2.0
Standard Operating Procedure for Cleaning and Decontamination of Cell Culture Areas in Biosimilar Labs
Department |
Biosimilars |
SOP No. |
SOP/BS/047/2025 |
Supersedes |
SOP/BS/047/2022 |
Page No. |
Page 1 of 10 |
Issue Date |
04/05/2025 |
Effective Date |
06/05/2025 |
Review Date |
04/05/2026 |
1. Purpose
To describe the procedure for routine cleaning and decontamination of cell culture laboratories used in biosimilar development to maintain aseptic processing conditions and prevent microbial or cross-contamination.
2. Scope
This SOP is applicable to all ISO-classified biosimilar laboratories, clean rooms, and associated areas involved in mammalian cell culture processes.
3. Responsibilities
- Housekeeping Staff: Perform scheduled cleaning as per instructions using approved disinfectants.
- Lab Technicians: Ensure work surfaces and biosafety cabinets are disinfected before and after use.
- QA Team: Verify cleaning records and conduct cleanliness inspections.
4. Accountability
The Head of Biosimilar Operations is accountable for ensuring adherence to this cleaning SOP, and maintaining contamination-free culture environments.
5. Procedure
5.1 Cleaning Frequency and Schedule
- Daily:
- Floor mopping with disinfectant
- Wipe workbenches, door handles, switches
- Weekly:
- Wall and ceiling wipe-down
- Clean drains and air vent covers
- Monthly:
- Disinfection behind equipment and storage cabinets
5.2 Cleaning Agents and Disinfectants
- Use approved disinfectants such as:
- 70% Isopropyl Alcohol (IPA)
- 1% Sodium Hypochlorite
- 0.5% Hydrogen Peroxide
- Rotate disinfectants monthly to avoid resistance.
- Maintain Disinfectant Preparation and Usage Log (Annexure-1).
5.3 Cleaning Technique
- Follow unidirectional wiping — top to bottom, clean to dirty.
- Use sterile lint-free wipes; discard after single use.
- For floors, use color-coded mop heads specific to area classification.
- Do not re-use contaminated wipes or mops.
5.4 Biosafety Cabinet Decontamination
- Before each use:
- Wipe all surfaces with 70% IPA
- Allow 10-minute air purge after blower startup
- Weekly:
- Clean base tray, sash, and side walls
- Record in BSC Cleaning Log (Annexure-2)
5.5 Fumigation and Terminal Decontamination
- Performed quarterly or during contamination incidents.
- Use fogging with validated agents (e.g., 6% hydrogen peroxide).
- Document in the Terminal Decontamination Log (Annexure-3).
5.6 Waste Handling During Cleaning
- Collect used wipes, PPE, and disposables in biohazard bags.
- Dispose as per biohazard SOP for contaminated materials.
- Label and segregate infectious waste from general lab trash.
5.7 Documentation
- Fill cleaning records immediately after completion.
- Records to be signed by cleaning personnel and verified by lab-in-charge or QA.
6. Abbreviations
- IPA: Isopropyl Alcohol
- BSC: Biosafety Cabinet
- QA: Quality Assurance
7. Documents
- Disinfectant Preparation and Usage Log (Annexure-1)
- BSC Cleaning Log (Annexure-2)
- Terminal Decontamination Log (Annexure-3)
8. References
- WHO TRS 961 – GMP for Biological Products
- Schedule M – Good Manufacturing Practices (India)
- ICH Q9 – Quality Risk Management
9. SOP Version
Version: 2.0
10. Approval Section
|
Prepared By |
Checked By |
Approved By |
Signature |
|
|
|
Date |
|
|
|
Name |
|
|
|
Designation |
|
|
|
Department |
|
|
|
11. Annexures
Annexure-1: Disinfectant Preparation and Usage Log
Date |
Disinfectant |
Concentration |
Prepared By |
Used In |
03/05/2025 |
Hydrogen Peroxide |
0.5% |
Ajay Verma |
CLD Room |
Annexure-2: BSC Cleaning Log
Date |
Cabinet ID |
Surface Cleaned |
Cleaned By |
Verified By |
04/05/2025 |
BSC-102 |
Interior, Tray |
Sunita Reddy |
Vinay Pawar |
Annexure-3: Terminal Decontamination Log
Date |
Room ID |
Agent Used |
Method |
Performed By |
01/04/2025 |
CLD-1 |
6% H₂O₂ |
Fogging |
QA Team |
Revision History:
Revision Date |
Revision No. |
Revision Details |
Reason for Revision |
Approved By |
04/05/2025 |
2.0 |
Added fumigation and wall cleaning guidance |
Routine SOP Upgrade |
|