Biosimilars: SOP for Cell Retention System Use (ATF, TFF) – V 2.0
Standard Operating Procedure for Cell Retention System Use (ATF, TFF) in Biosimilar Manufacturing
| Department |
Biosimilars |
| SOP No. |
SOP/BS/144/2025 |
| Supersedes |
SOP/BS/144/2022 |
| Page No. |
Page 1 of 11 |
| Issue Date |
04/05/2025 |
| Effective Date |
06/05/2025 |
| Review Date |
04/05/2026 |
1. Purpose
To establish a standard procedure for the installation, operation, monitoring, and cleaning of cell retention systems such as Alternating Tangential Flow (ATF) and Tangential Flow Filtration (TFF) units used in high-density perfusion-based biosimilar production.
2. Scope
This SOP applies to upstream operations in biosimilar manufacturing where continuous culture and high cell density are maintained using ATF or TFF modules integrated with bioreactor systems.
3. Responsibilities
- Upstream Production: Setup, monitor, and operate cell retention system during batch/perfusion process.
- Engineering: Maintain and calibrate ATF/TFF hardware and monitor pressure integrity.
- QA: Approve protocols and deviations related to the retention system.
4. Accountability
The Upstream Process Head is accountable for ensuring proper operation, maintenance, and documentation of cell retention systems in accordance with validated protocols and GMP guidelines.
5. Procedure
5.1 Equipment Preparation
- Verify system model and specifications from approved list in Annexure-1: ATF/TFF System Tracker.
- Check availability of:
- Single-use hollow fiber or membrane module
- Tubing sets and clamps
- Sterile filtration units (0.2 µm)
- Connect system to designated bioreactor port with flow direction matching diagram.
5.2 Pre-Use Integrity and Flushing
- Flush the loop with WFI to remove preservative.
- Perform pressure hold test:
- Maintain 0.8 bar for 5 mins with ≤10% pressure drop.
- Record results in Annexure-2: Retention System Integrity Log.
5.3 Operation During Culture
- Initiate perfusion by activating ATF/TFF circulation at defined start cell density (e.g., 20 x 10⁶ cells/mL).
- Set recirculation rate and transmembrane pressure (TMP):
- ATF: 0.3–0.5 bar TMP
- TFF: 10–20 L/m²/hr flux rate
- Monitor:
- Cell viability and retention rate
- Fouling indicators (pressure rise)
- Filtrate turbidity
- Log parameters every 4 hours in Annexure-3.
5.4 End-of-Batch Handling
- Stop feed and disconnect cell retention loop under aseptic conditions.
- Flush loop with WFI and decontaminate with NaOH or peracetic acid as per membrane compatibility.
- Dispose of single-use components in biohazard containers.
5.5 Deviation Management
- Record:
- Flow interruption
- Pressure anomalies
- Unexpected filtrate appearance
- Notify QA and file deviation report (Annexure-4).
6. Abbreviations
- ATF: Alternating Tangential Flow
- TFF: Tangential Flow Filtration
- TMP: Transmembrane Pressure
- QA: Quality Assurance
- WFI: Water for Injection
7. Documents
- ATF/TFF System Tracker – Annexure-1
- Retention System Integrity Log – Annexure-2
- Perfusion Run Monitoring Log – Annexure-3
- Deviation Report – Annexure-4
8. References
- WHO TRS 1025 – Guidelines on Continuous Manufacturing
- USP <1051> – Bioreactor Systems
- EU GMP Annex 15 – Qualification and Validation
9. SOP Version
Version: 2.0
10. Approval Section
|
Prepared By |
Checked By |
Approved By |
| Signature |
|
|
|
| Date |
|
|
|
| Name |
|
|
|
| Designation |
|
|
|
| Department |
|
|
|
11. Annexures
Annexure-1: ATF/TFF System Tracker
| System ID |
Type |
Module Serial No. |
Installation Date |
Status |
| CR-ATF-102 |
ATF |
HF-5087A |
01/05/2025 |
Active |
Annexure-2: Retention System Integrity Log
| Date |
System ID |
Pressure Hold (bar) |
Drop % |
Status |
Checked By |
| 02/05/2025 |
CR-ATF-102 |
0.8 |
5% |
Pass |
Ajay Verma |
Annexure-3: Perfusion Run Monitoring Log
| Time |
VCD |
Viability |
TMP (bar) |
Flow Rate (L/hr) |
Remarks |
| 10:00 |
26.4 |
95% |
0.42 |
1.2 |
Normal |
Annexure-4: Deviation Report
| Date |
Description |
Action Taken |
Reported By |
QA Status |
| 04/05/2025 |
Spike in TMP |
Membrane flushed with WFI |
Sunita Reddy |
Open |
Revision History:
| Revision Date |
Revision No. |
Revision Details |
Reason for Revision |
Approved By |
| 04/05/2025 |
2.0 |
Included deviation management and TMP monitoring |
Regulatory compliance update |
|