SOP Guide for Pharma

API Manufacturing: SOP for Raw Material Sampling Procedure – V 2.0

API Manufacturing: SOP for Raw Material Sampling Procedure – V 2.0

Standard Operating Procedure for Raw Material Sampling Procedure in API Manufacturing

Department API Manufacturing
SOP No. SOP/API/003/2025
Supersedes SOP/API/003/2022
Page No. Page 1 of 10
Issue Date 13/04/2025
Effective Date 15/04/2025
Review Date 13/04/2026

1. Purpose

To describe the procedure for sampling of raw materials such as APIs, excipients, and solvents in a GMP-compliant manner to ensure samples taken for analysis are representative of the entire batch or lot.

2. Scope

This procedure applies to all personnel involved in raw material sampling in the warehouse sampling booth or designated sampling area in the API manufacturing facility.

3. Responsibilities

4. Accountability

The Head of Quality Control is accountable for ensuring proper implementation of sampling procedures and compliance with GMP requirements.

5. Procedure

5.1 Preparation for Sampling

  1. Ensure sampling is performed in a dedicated, validated sampling booth with differential pressure and HEPA filtration.
  2. Check environmental conditions and log temperature, humidity, and pressure differentials before starting.
  3. Wear appropriate personal protective equipment (PPE) as per gowning SOP.
  4. Verify cleanliness of sampling tools and containers; sterilize if required.

5.2 Sampling Plan and Strategy

  1. Follow the sampling plan as per ICH Q7 or √n+1 approach:
    • √n+1, where n = total number of containers
    • Minimum of 10% of total containers must be sampled
  2. Sample randomly from different positions – top, middle, bottom – using a thief sampler, scoop, or zone sampler.
  3. Prepare both individual samples (if required) and a composite sample for routine analysis.
  4. Use clean and inert sampling containers labeled with:
    • Material name
    • Batch number
    • Date of sampling
    • Sampled by (initials)

5.3 Sampling Procedure

  1. Place containers on a designated platform and inspect physical condition before opening.
  2. Use pre-sanitized tools and avoid contamination during sampling.
  3. Open each selected container under LAF and take sample volume as specified in the material specification file.
  4. Record the sample weight and seal containers properly after sampling.
  5. Affix “Sampled” labels on all containers from which samples were drawn.

5.4 Sample Transfer and Documentation

  1. Transfer samples to the QC lab with the “Sample Transfer Form” (Annexure-2).
  2. Document all details in the “Raw Material Sampling Log” (Annexure-1), including number of containers sampled, tool used, sample quantity, and sampling personnel.
  3. If a sample shows any unusual appearance or odor, notify QA and record it in the deviation register.

5.5 Cleaning and Closure

  1. After sampling, clean the sampling booth and disinfect all used tools.
  2. Update the cleaning log and leave the area ready for the next activity.

6. Abbreviations

7. Documents

  1. Raw Material Sampling Log (Annexure-1)
  2. Sample Transfer Form (Annexure-2)
  3. Sampling Plan Template (Annexure-3)

8. References

9. SOP Version

Version: 2.0

10. Approval Section

Prepared By Checked By Approved By
Signature
Date
Name Rajesh Kumar Sunita Reddy Manoj Verma
Designation QC Officer QA Executive QA Manager
Department API Manufacturing Quality Assurance Quality Assurance

11. Annexures

Annexure-1: Raw Material Sampling Log

Date Material Batch No. No. of Containers Qty Sampled Sampled By
13/04/2025 Citric Acid CA20250413 10 500g Rajesh Kumar

Annexure-2: Sample Transfer Form

Date Material Batch No. Transferred To Transferred By
13/04/2025 Citric Acid CA20250413 QC Laboratory Sunita Reddy

Annexure-3: Sampling Plan Template

Total Containers Sampling Plan Used No. of Containers Sampled Approach
10 √n+1 4 Random + Stratified

Revision History:

Revision Date Revision No. Revision Details Reason for Revision Approved By
01/01/2022 1.0 Initial Release New SOP QA Head
13/04/2025 2.0 Added Sample Plan and Transfer Protocol Annual SOP Review QA Head
Exit mobile version