SOP Guide for Pharma

API Manufacturing: SOP for Cleaning Validation Between Batches – V 2.0

API Manufacturing: SOP for Cleaning Validation Between Batches – V 2.0

Standard Operating Procedure for Cleaning Validation Between Batches in API Manufacturing

Department API Manufacturing
SOP No. SOP/API/038/2025
Supersedes SOP/API/038/2022
Page No. Page 1 of 10
Issue Date 13/04/2025
Effective Date 15/04/2025
Review Date 13/04/2026

1. Purpose

To define a validated procedure for cleaning validation between batches of different or same products in API manufacturing to ensure the removal of any residual active ingredients, cleaning agents, or microbial contaminants.

2. Scope

This SOP applies to all equipment, containers, and contact parts used in API production that require cleaning validation between batches of the same or different products.

3. Responsibilities

4. Accountability

The QA Head is accountable for the approval and implementation of the cleaning validation program. The Production Head ensures compliance during manufacturing operations.

5. Procedure

5.1 Cleaning Validation Strategy

  1. Identify product changeover, worst-case product, shared equipment, and sampling locations.
  2. Prepare and approve a cleaning validation protocol for:
    • Equipment type
    • Cleaning method
    • Acceptance limits
    • Sampling plan

5.2 Cleaning Process Execution

  1. Clean the equipment as per the approved cleaning SOP.
  2. Record all details in the cleaning checklist and cleaning logbook.
  3. Allow equipment to dry and label as “Cleaned — Awaiting Sampling.”

5.3 Sampling Procedure

  1. Swab or rinse sampling shall be performed by trained QC personnel.
  2. Swab locations must represent worst-case areas:
    • Dead corners
    • Scratches or weld joints
    • Difficult-to-clean parts
  3. Record swab area (usually 25 cm²) and location in the “Cleaning Validation Sampling Log” (Annexure-1).
  4. Submit samples to QC for analysis within defined hold time.

5.4 Analytical Testing and Limits

  1. Analyze samples for:
    • Active ingredient residue
    • Detergent residue
    • Microbial contamination (if required)
  2. Compare results with established acceptance criteria:
    • Not more than 10 ppm of previous product (unless otherwise justified)
    • No visible residue
    • Rinse water: pH and conductivity within limits

5.5 Documentation and Validation Report

  1. Compile all test data, raw results, and equipment details in the Cleaning Validation Report (Annexure-2).
  2. QA to review, approve, and archive the report.
  3. Update master cleaning SOP with validated parameters and frequency based on results.

6. Abbreviations

7. Documents

  1. Cleaning Validation Sampling Log (Annexure-1)
  2. Cleaning Validation Report Template (Annexure-2)
  3. Swab Test Analytical Report (Annexure-3)

8. References

9. SOP Version

Version: 2.0

10. Approval Section

Prepared By Checked By Approved By
Signature
Date
Name
Designation
Department

11. Annexures

Annexure-1: Cleaning Validation Sampling Log

Date Equipment ID Product Swab Location Area (cm²) Collected By
13/04/2025 DR-101 API-X Agitator Blade 25

Annexure-2: Cleaning Validation Report Template

Batch No. Product Previous Product Equipment Validation Status
API-202504 API-X API-Y R-205 Pass

Annexure-3: Swab Test Analytical Report

Sample ID Analyte Result (ppm) Limit (ppm) Status
SWB-101 API-Y 0.7 ≤10 Pass

Revision History:

Revision Date Revision No. Details Reason Approved By
01/01/2022 1.0 Initial SOP Release New Equipment Validation QA Head
13/04/2025 2.0 Inclusion of microbial testing and revised limits Audit Findings QA Head