Skip to content
  • Clinical Studies
  • Schedule M
  • Stability Studies
  • Pharma GMP
  • Pharma Tips
  • Pharma Books
  • Pharma Validation
  • Pharma Regulatory

SOP Guide for Pharma

The Ultimate Resource for Pharmaceutical SOPs and Best Practices

  • Home
  • SOP Guidelines
    • SOP Development
    • SOP Training
    • SOP Compliance Monitoring
    • SOP Revision Processes
    • Pharmaceutical SOP templates
    • GMP documentation SOP
    • Data integrity SOP pharma
    • Manufacturing SOP pharmaceutical
    • FDA SOP guidance
    • eQMS SOP workflows
  • Job Safety Analysis (JSA)
    • Oral Dosage Forms (Tablets & Capsules)
    • Oral Liquid Dosage Forms (Syrups, Elixirs, Suspensions, Emulsions)
    • Powder and Granule Dosage Forms
    • Topical Dosage Forms (Creams, Ointments, Gels, Lotions, Pastes)
    • Transdermal Dosage Forms (Patches)
  • Standard Test Procedures (STP)
  • GMP Audit Findings
    • Non-Compliance
      • SOP Absence
      • Revision Control
      • Non-Adherence
      • Poor Writing
      • Training Failure
      • Data Integrity Gaps
      • Mismatch Between SOPs and Practice
      • Critical Operations
      • Regulatory Change
      • Emergency Changes
      • Third-Party SOPs
      • Inspection Readiness
      • Deviation Handling
      • CAPA Integration
      • Validation Alignment
      • System Integration
      • Uncontrolled Distribution
      • SOP Implementation Gaps
      • SOP Alignment with Validation
      • Change Control Linkage
  • Toggle search form

Analytical Method Development: UV Method for API Assay – V 2.0

Posted on By

Analytical Method Development: UV Method for API Assay – V 2.0

SOP for UV Spectrophotometric Method Development for API Assay


Department Analytical Method Development
SOP No. SOP/AMD/091/2025
Supersedes SOP/AMD/091/2022
Page No. Page 1 of 14
Issue Date 19/05/2025
Effective Date 20/05/2025
Review Date 19/05/2026

1. Purpose

The purpose of this SOP is to define a standardized procedure for developing a UV spectrophotometric method for the quantitative assay of Active Pharmaceutical Ingredients (APIs). The SOP ensures that the method developed

is precise, accurate, and robust for quality control and validation.

2. Scope

This SOP applies to the Analytical Method Development (AMD) department and covers all UV-based assay method development activities for APIs in powder or solution form, either as raw materials or within finished dosage forms.

3. Responsibilities

  • Analytical Chemist: Performs method development, standard/sample preparation, wavelength selection, and result documentation.
  • Reviewer: Verifies method linearity, precision, and assay results.
  • QA Officer: Reviews all records for compliance with GMP, GLP, and ICH standards.
  • Head – AMD: Approves the developed method and authorizes it for validation and routine use.

See also  Analytical Method Development: SOP for Documentation Review Before Report Finalization - V 2.0

4. Accountability

The Head of Analytical Method Development is accountable for ensuring the integrity, reliability, and regulatory compliance of all UV-based assay methods developed and implemented in the department.

5. Procedure

5.1 Wavelength Selection

  1. Scan the UV spectrum of the API (200–400 nm) using a UV-visible spectrophotometer.
  2. Identify the wavelength of maximum absorbance (λmax) and verify absence of interferences.
  3. Ensure molar absorptivity is sufficient (A > 0.1 for 1% solution at 1 cm path length).
  4. Record spectrum and selected λmax in Annexure-1: UV Scanning Report.

5.2 Standard and Sample Preparation

  1. Weigh accurately ~10 mg of API (standard) and transfer to a 100 mL volumetric flask.
  2. Dissolve in suitable solvent (water, methanol, ethanol, etc.).
  3. Sonicate if required. Dilute to mark to obtain working concentration (e.g., 10–25 µg/mL).
  4. Prepare sample using identical solvent and conditions as standard.
  5. Log preparation details in Annexure-2: Preparation Log.

5.3 Calibration Curve and Linearity

  1. Prepare standard solutions at five concentrations: 50%, 75%, 100%, 125%, and 150% of target assay level.
  2. Measure absorbance at λmax using matched quartz cuvettes (1 cm path length).
  3. Plot absorbance vs concentration and determine linearity (R² ≥ 0.995).
  4. Calculate slope, intercept, and %RSD of replicate readings.
  5. Document results in Annexure-3: Linearity and Calibration Record.
See also  Analytical Method Development: Loss on Drying (LOD) Method Development - V 2.0

5.4 Assay Calculation

  1. Use Beer–Lambert Law for single-point assay:
    Assay (%) = (Abs_sample / Abs_standard) × (Conc_standard / Conc_sample) × 100
    
  2. Apply appropriate dilution factors and record final assay %.
  3. Document in Annexure-4: Assay Result Sheet.

5.5 Method Precision and Accuracy

  1. Perform six replicate determinations at 100% concentration level.
  2. Calculate %RSD for precision (acceptable: ≤2.0%).
  3. Conduct recovery studies by spiking placebo with known quantities of standard (80%, 100%, 120%).
  4. Calculate % recovery and log in Annexure-5: Precision and Recovery Report.

5.6 Specificity and Placebo Interference

  1. Scan placebo solution to ensure no absorbance at selected λmax.
  2. Overlay placebo and standard spectra to verify absence of overlap or interfering peaks.
  3. Document results in Annexure-6: Specificity Evaluation Sheet.

5.7 System Suitability

  1. Measure absorbance of six replicates of standard solution at assay level.
  2. Acceptance Criteria:
    • %RSD ≤ 2.0%
    • Absorbance range: ±0.010 from mean
  3. Record results in Annexure-7: System Suitability Log.

6. Abbreviations

  • UV: Ultraviolet
  • API: Active Pharmaceutical Ingredient
  • λmax: Wavelength of Maximum Absorbance
  • RSD: Relative Standard Deviation
  • SOP: Standard Operating Procedure

7. Documents

  1. UV Scanning Report – Annexure-1
  2. Preparation Log – Annexure-2
  3. Linearity and Calibration Record – Annexure-3
  4. Assay Result Sheet – Annexure-4
  5. Precision and Recovery Report – Annexure-5
  6. Specificity Evaluation Sheet – Annexure-6
  7. System Suitability Log – Annexure-7
See also  Analytical Method Development: SOP for Conducting Inter-Laboratory Analytical Method Comparability - V 2.0

8. References

  • ICH Q2(R1) – Validation of Analytical Procedures
  • USP <857> – Ultraviolet-Visible Spectroscopy
  • USP <1225> – Validation of Compendial Procedures
  • FDA Guidance for Industry – Analytical Procedures and Methods Validation

9. SOP Version

Version: 2.0

10. Approval Section

Prepared By Checked By Approved By
Signature
Date
Name
Designation
Department

11. Annexures

Annexure-1: UV Scanning Report

Sample ID Solvent Scan Range λmax (nm)
API-UV-101 Water 200–400 nm 274

Annexure-2: Preparation Log

Type Amount Weighed Diluent Final Volume Prepared By
Standard 10.2 mg Water 100 mL Rajesh Kumar

Annexure-3: Linearity and Calibration Record

Concentration (µg/mL) Absorbance
10 0.246
15 0.370
20 0.491
25 0.612
30 0.735

Annexure-4: Assay Result Sheet

Sample ID Absorbance Assay (%)
SMP-001 0.485 98.7%

Annexure-5: Precision and Recovery Report

Spike Level % Recovery % RSD
100% 99.2% 1.2%

Annexure-6: Specificity Evaluation Sheet

Solution Absorbance at λmax Inference
Placebo 0.002 No interference

Annexure-7: System Suitability Log

Replicate Absorbance
1 0.491
2 0.490
3 0.489
4 0.492
5 0.491
6 0.490

Revision History:

Revision Date Revision No. Details Reason Approved By
04/05/2025 2.0 Expanded linearity range and updated specificity protocol Annual SOP Review
Analytical Method Development V 2.0 Tags:Analytical Method Development SOP, SOP for analytical calculations, SOP for analytical documentation, SOP for analytical instrument calibration, SOP for analytical instrument qualification, SOP for analytical method change control, SOP for analytical method deviation handling, SOP for analytical method documentation practices, SOP for analytical method lifecycle management, SOP for analytical method optimization, SOP for analytical method risk assessment, SOP for analytical method training and competency, SOP for analytical method transfer protocol, SOP for analytical method validation, SOP for forced degradation studies, SOP for HPLC method development, SOP for limit of detection (LOD) determination, SOP for limit of quantitation (LOQ) determination, SOP for method accuracy testing, SOP for method linearity assessment, SOP for method precision evaluation, SOP for method reproducibility, SOP for method robustness testing, SOP for method transfer, SOP for method verification, SOP for qualification of working standards, SOP for reference standard handling, SOP for specificity testing in analytical methods, SOP for stability indicating methods, SOP for system suitability testing

Post navigation

Previous Post: Gel Manufacturing: SOP for Labeling Machines for Gel Packaging – V 2.0
Next Post: Sterile Injectable Manufacturing: SOP for Cross-Verification of Dispensed Materials – V 2.0

Standard Operating Procedures V 1.0

  • Aerosols
  • Analytical Method Development
  • Bioequivalence Bioavailability Study
  • Capsule Formulation
  • Clinical Studies
  • Creams
  • Data Integrity
  • Dental Dosage Forms
  • Drug Discovery
  • Environment, Health and Safety
  • Formulation Development
  • Gels
  • Good Distribution Practice
  • Good Warehousing Practices
  • In-Process Control
  • Injectables
  • Liquid Orals
  • Liposome and Emulsion Formulations
  • Lotions
  • Lyophilized Products
  • Maintenance Dept.
  • Medical Devices
  • Metered-Dose Inhaler
  • Microbiology Testing
  • Nanoparticle Formulation
  • Nasal Spray Formulations
  • Nebulizers
  • Ocular (Eye) Dosage Forms
  • Ointments
  • Otic (Ear) Dosage Forms
  • Pharmacovigilance
  • Powder & Granules
  • Purchase Departments
  • Quality Assurance
  • Quality Control
  • Raw Material Stores
  • Regulatory Affairs
  • Tablet Manufacturing
  • Rectal Dosage Forms
  • Transdermal Patches
  • Vaginal Dosage Forms
  • Validations and Qualifications

Read SOPs in your Language:

 - 
Bengali
 - 
bn
English
 - 
en
Gujarati
 - 
gu
Hindi
 - 
hi
Malayalam
 - 
ml
Marathi
 - 
mr
Punjabi
 - 
pa
Tamil
 - 
ta
Telugu
 - 
te

NEW! Revised SOPs – V 2.0

  • Aerosols V 2.0
  • Analytical Method Development V 2.0
  • API Manufacturing V 2.0
  • BA-BE Studies V 2.0
  • Biosimilars V 2.0
  • Capsules V 2.0
  • Creams V 2.0
  • Elixers V 2.0
  • Gels V 2.0
  • Injectables V 2.0
  • Ointments V 2.0
  • Raw Material Warehouse V 2.0
  • Tablet Manufacturing V2.0

New Publication: A must for All.

Copyright © 2025 SOP Guide for Pharma.

Powered by PressBook WordPress theme

Go to mobile version