Skip to content
  • Clinical Studies
  • Schedule M
  • Stability Studies
  • Pharma GMP
  • Pharma Tips
  • Pharma Books
  • Pharma Validation
  • Pharma Regulatory

SOP Guide for Pharma

The Ultimate Resource for Pharmaceutical SOPs and Best Practices

  • Home
  • SOP Guidelines
    • SOP Development
    • SOP Training
    • SOP Compliance Monitoring
    • SOP Revision Processes
    • Pharmaceutical SOP templates
    • GMP documentation SOP
    • Data integrity SOP pharma
    • Manufacturing SOP pharmaceutical
    • FDA SOP guidance
    • eQMS SOP workflows
  • Job Safety Analysis (JSA)
    • Oral Dosage Forms (Tablets & Capsules)
    • Oral Liquid Dosage Forms (Syrups, Elixirs, Suspensions, Emulsions)
    • Powder and Granule Dosage Forms
    • Topical Dosage Forms (Creams, Ointments, Gels, Lotions, Pastes)
    • Transdermal Dosage Forms (Patches)
  • Standard Test Procedures (STP)
  • GMP Audit Findings
    • Non-Compliance
      • SOP Absence
      • Revision Control
      • Non-Adherence
      • Poor Writing
      • Training Failure
      • Data Integrity Gaps
      • Mismatch Between SOPs and Practice
      • Critical Operations
      • Regulatory Change
      • Emergency Changes
      • Third-Party SOPs
      • Inspection Readiness
      • Deviation Handling
      • CAPA Integration
      • Validation Alignment
      • System Integration
      • Uncontrolled Distribution
      • SOP Implementation Gaps
      • SOP Alignment with Validation
      • Change Control Linkage
  • Toggle search form

Analytical Method Development: SOP for Qualification of Glassware Used in AMD – V 2.0

Posted on By

Analytical Method Development: SOP for Qualification of Glassware Used in AMD – V 2.0

Standard Operating Procedure for Qualification of Glassware in Analytical Method Development


Department Analytical Method Development
SOP No. SOP/AMD/319/2025
Supersedes SOP/AMD/319/2022
Page No. Page 1 of 11
Issue Date 01/06/2025
Effective Date 03/06/2025
Review Date 01/06/2026

1. Purpose

This SOP defines the process for the qualification and requalification of volumetric and non-volumetric glassware used in the Analytical Method Development (AMD) department. It ensures accuracy in measurement and compliance with regulatory standards.

2. Scope

This procedure

applies to all glassware used in the AMD department including pipettes, burettes, volumetric flasks, beakers, and measuring cylinders involved in analytical testing, method validation, and stability studies.

3. Responsibilities

  • AMD Analyst: Performs glassware qualification and records data in the qualification logbook.
  • QA Personnel: Reviews qualification data and approves glassware for use.
  • AMD Section Head: Ensures adherence to qualification schedules and regulatory compliance.
See also  Analytical Method Development: Integration with Product Development Team - V 2.0

4. Accountability

The Head of Analytical Method Development is accountable for ensuring that all glassware used in the laboratory is qualified, documented, and meets accuracy standards as per pharmacopeial and GMP requirements.

5. Procedure

5.1 Types of Glassware Covered

  • Volumetric flasks (Class A or B)
  • Measuring cylinders
  • Beakers and conical flasks
  • Burettes and pipettes
  • Glass rods and funnels

5.2 Qualification Frequency

  1. Initial qualification must be done before first use.
  2. Requalification should be performed annually or after physical damage/repair.

5.3 Qualification of Volumetric Glassware

  1. Use purified water with known density at 25°C for calibration.
  2. Weigh empty glassware using a calibrated balance.
  3. Fill to calibration mark and weigh again.
  4. Calculate volume using water density and weight difference.
  5. Compare with nominal volume; acceptance limit: ±0.2% of stated volume for Class A.

5.4 Qualification of Pipettes and Burettes

  1. Use gravimetric method with calibrated balance.
  2. Deliver water from pipette or burette and weigh the delivered quantity.
  3. Repeat process three times and calculate average volume delivered.
  4. Determine error and precision; permissible deviation should not exceed ±0.5%.
See also  Analytical Method Development: SOP for Emulsion and Suspension Method Development - V 2.0

5.5 Recording and Documentation

  1. Record qualification data in the Glassware Qualification Log (Annexure-1).
  2. Label each qualified item with unique ID and date of qualification.
  3. Maintain requalification due dates and track with master calibration schedule.

5.6 Handling of Non-Conforming Glassware

  1. Glassware failing qualification shall be marked as “Rejected” and removed from service.
  2. Root Cause Analysis (RCA) shall be conducted if repeated failure occurs.
  3. Prepare and submit Non-Conformance Report (Annexure-2) for QA review.

6. Abbreviations

  • AMD: Analytical Method Development
  • QA: Quality Assurance
  • RCA: Root Cause Analysis
  • SOP: Standard Operating Procedure

7. Documents

  1. Glassware Qualification Log – Annexure-1
  2. Non-Conformance Report – Annexure-2
  3. Glassware Label Template – Annexure-3

8. References

  • USP General Chapter <659> – Packaging and Storage Requirements
  • ICH Q6A – Specifications
  • 21 CFR Part 211.63 – Equipment Design, Size, and Location
  • WHO Good Practices for Quality Control Laboratories

9. SOP Version

Version: 2.0

10. Approval Section

Prepared By Checked By Approved By
Signature
Date
Name Ankita Rawat Deepak Shukla Dr. Harshita Goyal
Designation QA Chemist QA Officer Head – Analytical Method Development
Department Quality Assurance Quality Assurance Analytical Method Development

11. Annexures

Annexure-1: Glassware Qualification Log

Glassware ID Type Volume Qualification Date Status
GF-319-01 Volumetric Flask 100 mL 30/05/2025 Qualified

Annexure-2: Non-Conformance Report

Describes glassware ID, observed deviation, probable cause, and corrective actions taken.

Annexure-3: Glassware Label Template

Label should include: Glassware ID, qualification date, next due date, qualified by initials.

Revision History:

Revision Date Revision No. Details Reason Approved By
01/06/2025 2.0 Added detailed RCA and calibration error limits Annual SOP Review Dr. Harshita Goyal
10/08/2022 1.0 Initial SOP Release New SOP QA Head
See also  Analytical Method Development: SOP for System Performance Qualification of FTIR Spectrophotometer - V 2.0
Analytical Method Development V 2.0 Tags:Analytical Method Development SOP, SOP for analytical calculations, SOP for analytical documentation, SOP for analytical instrument calibration, SOP for analytical instrument qualification, SOP for analytical method change control, SOP for analytical method deviation handling, SOP for analytical method documentation practices, SOP for analytical method lifecycle management, SOP for analytical method optimization, SOP for analytical method risk assessment, SOP for analytical method training and competency, SOP for analytical method transfer protocol, SOP for analytical method validation, SOP for forced degradation studies, SOP for HPLC method development, SOP for limit of detection (LOD) determination, SOP for limit of quantitation (LOQ) determination, SOP for method accuracy testing, SOP for method linearity assessment, SOP for method precision evaluation, SOP for method reproducibility, SOP for method robustness testing, SOP for method transfer, SOP for method verification, SOP for qualification of working standards, SOP for reference standard handling, SOP for specificity testing in analytical methods, SOP for stability indicating methods, SOP for system suitability testing

Post navigation

Previous Post: Elixir Department: SOP for Endotoxin Testing – V 2.0
Next Post: Analytical Method Development: SOP for Maintaining Instrument Calibration Schedules – V 2.0

Standard Operating Procedures V 1.0

  • Aerosols
  • Analytical Method Development
  • Bioequivalence Bioavailability Study
  • Capsule Formulation
  • Clinical Studies
  • Creams
  • Data Integrity
  • Dental Dosage Forms
  • Drug Discovery
  • Environment, Health and Safety
  • Formulation Development
  • Gels
  • Good Distribution Practice
  • Good Warehousing Practices
  • In-Process Control
  • Injectables
  • Liquid Orals
  • Liposome and Emulsion Formulations
  • Lotions
  • Lyophilized Products
  • Maintenance Dept.
  • Medical Devices
  • Metered-Dose Inhaler
  • Microbiology Testing
  • Nanoparticle Formulation
  • Nasal Spray Formulations
  • Nebulizers
  • Ocular (Eye) Dosage Forms
  • Ointments
  • Otic (Ear) Dosage Forms
  • Pharmacovigilance
  • Powder & Granules
  • Purchase Departments
  • Quality Assurance
  • Quality Control
  • Raw Material Stores
  • Regulatory Affairs
  • Tablet Manufacturing
  • Rectal Dosage Forms
  • Transdermal Patches
  • Vaginal Dosage Forms
  • Validations and Qualifications

Read SOPs in your Language:

 - 
Bengali
 - 
bn
English
 - 
en
Gujarati
 - 
gu
Hindi
 - 
hi
Malayalam
 - 
ml
Marathi
 - 
mr
Punjabi
 - 
pa
Tamil
 - 
ta
Telugu
 - 
te

NEW! Revised SOPs – V 2.0

  • Aerosols V 2.0
  • Analytical Method Development V 2.0
  • API Manufacturing V 2.0
  • BA-BE Studies V 2.0
  • Biosimilars V 2.0
  • Capsules V 2.0
  • Creams V 2.0
  • Elixers V 2.0
  • Gels V 2.0
  • Injectables V 2.0
  • Ointments V 2.0
  • Raw Material Warehouse V 2.0
  • Tablet Manufacturing V2.0

New Publication: A must for All.

Copyright © 2025 SOP Guide for Pharma.

Powered by PressBook WordPress theme

Go to mobile version