Skip to content
  • Clinical Studies
  • Schedule M
  • Stability Studies
  • Pharma GMP
  • Pharma Tips
  • Pharma Books
  • Pharma Validation
  • Pharma Regulatory

SOP Guide for Pharma

The Ultimate Resource for Pharmaceutical SOPs and Best Practices

  • Home
  • SOP Guidelines
    • SOP Development
    • SOP Training
    • SOP Compliance Monitoring
    • SOP Revision Processes
    • Pharmaceutical SOP templates
    • GMP documentation SOP
    • Data integrity SOP pharma
    • Manufacturing SOP pharmaceutical
    • FDA SOP guidance
    • eQMS SOP workflows
  • Job Safety Analysis (JSA)
    • Oral Dosage Forms (Tablets & Capsules)
    • Oral Liquid Dosage Forms (Syrups, Elixirs, Suspensions, Emulsions)
    • Powder and Granule Dosage Forms
    • Topical Dosage Forms (Creams, Ointments, Gels, Lotions, Pastes)
    • Transdermal Dosage Forms (Patches)
  • Standard Test Procedures (STP)
  • GMP Audit Findings
    • Non-Compliance
      • SOP Absence
      • Revision Control
      • Non-Adherence
      • Poor Writing
      • Training Failure
      • Data Integrity Gaps
      • Mismatch Between SOPs and Practice
      • Critical Operations
      • Regulatory Change
      • Emergency Changes
      • Third-Party SOPs
      • Inspection Readiness
      • Deviation Handling
      • CAPA Integration
      • Validation Alignment
      • System Integration
      • Uncontrolled Distribution
      • SOP Implementation Gaps
      • SOP Alignment with Validation
      • Change Control Linkage
  • Toggle search form

Analytical Method Development: Method Transfer for Dissolution Studies – V 2.0

Posted on By

Analytical Method Development: Method Transfer for Dissolution Studies – V 2.0

Standard Operating Procedure for Method Transfer of Dissolution Studies in Analytical Method Development


Department Analytical Method Development
SOP No. SOP/AMD/105/2025
Supersedes SOP/AMD/105/2022
Page No. Page 1 of 14
Issue Date 19/05/2025
Effective Date 20/05/2025
Review Date 19/05/2026

1. Purpose

This SOP defines the step-by-step process for transferring validated dissolution test methods from the Analytical Method Development (AMD) laboratory to the Quality Control (QC) laboratory or

any external testing laboratory. It ensures consistency, reproducibility, and compliance with ICH, FDA, and WHO regulatory expectations.

2. Scope

This SOP applies to all dissolution test methods developed in AMD and intended to be transferred to a QC lab (internal or contract site) for routine product release, stability testing, or validation support.

3. Responsibilities

  • Sending Lab (AMD): Prepares method transfer protocol, shares method details, provides standards, and supports training.
  • Receiving Lab (QC/External): Performs trial runs, documents results, and submits method transfer report.
  • QA Department: Ensures oversight of the process, reviews all documents, and approves outcomes.
  • Head – AMD: Authorizes initiation and completion of the method transfer activity.
See also  Analytical Method Development: Development of Assay Methods using Classical Techniques - V 2.0

4. Accountability

The Head of Analytical Method Development is accountable for ensuring that all method transfers are executed as per SOP, with documented evidence of successful performance at the receiving unit.

5. Procedure

5.1 Initiation and Planning

  1. Identify the dissolution method to be transferred and receiving location.
  2. Confirm that the method is validated or has acceptable pre-validation data.
  3. Draft a Method Transfer Protocol including:
    • Scope and objectives
    • Roles of sender and receiver
    • Acceptance criteria
    • Materials, standards, equipment
    • Timeline
  4. Obtain QA approval before execution.
  5. Document initiation in Annexure-1: Method Transfer Initiation Log.

5.2 Transfer of Method Details

  1. Provide the receiving lab with:
    • Final validated method (SOP format)
    • Analytical method validation report
    • Standard operating conditions and rationale
    • Reference standards and sample batch
    • Stability of standard and sample solution
  2. If equipment differences exist (e.g., different brand of dissolution tester), document rationale and adjust parameters only with scientific justification.
  3. Log all shared documents and materials in Annexure-2: Transfer Document Checklist.

5.3 Trial Runs at Receiving Lab

  1. Perform three sets of dissolution tests (n=6) using provided method and materials.
  2. Analyze and calculate:
    • % drug release at all time points
    • % RSD per time point
    • f2 similarity with AMD profile (if applicable)
  3. Ensure that results meet acceptance criteria:
    • % release variation ≤ 10%
    • % RSD ≤ 10% for all points
    • Profile matches reference profile with f2 ≥ 50
  4. Record data in Annexure-3: Receiving Lab Trial Report.
See also  Analytical Method Development: SOP for Accuracy Assessment Using Recovery Study - V 2.0

5.4 Troubleshooting (if required)

  1. If acceptance criteria are not met:
    • Conduct joint investigation by both labs
    • Evaluate system suitability, analyst error, instrument settings
    • Repeat runs under supervision if necessary
  2. Document all findings in Annexure-4: Deviation and Resolution Record.

5.5 Completion and Approval

  1. Compile a Method Transfer Report including:
    • Summary of trial results
    • Confirmation of acceptance criteria
    • Any deviations and corrective actions
  2. QA to review and approve final report.
  3. Update method status to “Transferred” in AMD records.
  4. Close project with approval from Head – AMD and Head – QC.
  5. Document in Annexure-5: Method Transfer Completion Log.

6. Abbreviations

  • QC: Quality Control
  • AMD: Analytical Method Development
  • RSD: Relative Standard Deviation
  • f2: Similarity Factor
  • SOP: Standard Operating Procedure

7. Documents

  1. Method Transfer Initiation Log – Annexure-1
  2. Transfer Document Checklist – Annexure-2
  3. Receiving Lab Trial Report – Annexure-3
  4. Deviation and Resolution Record – Annexure-4
  5. Method Transfer Completion Log – Annexure-5
See also  Analytical Method Development: Development of Drug Release Profile - V 2.0

8. References

  • ICH Q2(R1) – Validation of Analytical Procedures
  • WHO Technical Report Series – Transfer of Analytical Methods
  • USP <1224> – Transfer of Analytical Procedures

9. SOP Version

Version: 2.0

10. Approval Section

Prepared By Checked By Approved By
Signature
Date
Name
Designation
Department

11. Annexures

Annexure-1: Method Transfer Initiation Log

Method ID Product Transfer To Initiated By Date
AMD-MT-105 Tablet A QC Lab – Unit II Rajesh Kumar 15/05/2025

Annexure-2: Transfer Document Checklist

Document/Item Sent? Remarks
Method SOP Yes Verified
Reference Standard Yes Batch RS-23/2025
Validation Report Yes Full validation included

Annexure-3: Receiving Lab Trial Report

Trial No. % Released (30 min) % RSD Status
Trial 1 92.1% 3.2% Pass
Trial 2 91.8% 2.9% Pass
Trial 3 92.3% 3.5% Pass

Annexure-4: Deviation and Resolution Record

No deviations reported during method transfer trials.

Annexure-5: Method Transfer Completion Log

Transfer Date Receiving Analyst Reviewed By Final Approval
18/05/2025 Sunita Reddy QA Officer Head – AMD

Revision History:

Revision Date Revision No. Details Reason Approved By
04/05/2025 2.0 Added f2 similarity factor and annexures for trial reporting Annual Review
Analytical Method Development V 2.0 Tags:Analytical Method Development SOP, SOP for analytical calculations, SOP for analytical documentation, SOP for analytical instrument calibration, SOP for analytical instrument qualification, SOP for analytical method change control, SOP for analytical method deviation handling, SOP for analytical method documentation practices, SOP for analytical method lifecycle management, SOP for analytical method optimization, SOP for analytical method risk assessment, SOP for analytical method training and competency, SOP for analytical method transfer protocol, SOP for analytical method validation, SOP for forced degradation studies, SOP for HPLC method development, SOP for limit of detection (LOD) determination, SOP for limit of quantitation (LOQ) determination, SOP for method accuracy testing, SOP for method linearity assessment, SOP for method precision evaluation, SOP for method reproducibility, SOP for method robustness testing, SOP for method transfer, SOP for method verification, SOP for qualification of working standards, SOP for reference standard handling, SOP for specificity testing in analytical methods, SOP for stability indicating methods, SOP for system suitability testing

Post navigation

Previous Post: Sterile Injectable Manufacturing: SOP for Lyophilization Process in Injectable Manufacturing – V 2.0
Next Post: Aerosol: SOP for Conducting Internal Audits for Aerosol Manufacturing – V 2.0

Standard Operating Procedures V 1.0

  • Aerosols
  • Analytical Method Development
  • Bioequivalence Bioavailability Study
  • Capsule Formulation
  • Clinical Studies
  • Creams
  • Data Integrity
  • Dental Dosage Forms
  • Drug Discovery
  • Environment, Health and Safety
  • Formulation Development
  • Gels
  • Good Distribution Practice
  • Good Warehousing Practices
  • In-Process Control
  • Injectables
  • Liquid Orals
  • Liposome and Emulsion Formulations
  • Lotions
  • Lyophilized Products
  • Maintenance Dept.
  • Medical Devices
  • Metered-Dose Inhaler
  • Microbiology Testing
  • Nanoparticle Formulation
  • Nasal Spray Formulations
  • Nebulizers
  • Ocular (Eye) Dosage Forms
  • Ointments
  • Otic (Ear) Dosage Forms
  • Pharmacovigilance
  • Powder & Granules
  • Purchase Departments
  • Quality Assurance
  • Quality Control
  • Raw Material Stores
  • Regulatory Affairs
  • Tablet Manufacturing
  • Rectal Dosage Forms
  • Transdermal Patches
  • Vaginal Dosage Forms
  • Validations and Qualifications

Read SOPs in your Language:

 - 
Bengali
 - 
bn
English
 - 
en
Gujarati
 - 
gu
Hindi
 - 
hi
Malayalam
 - 
ml
Marathi
 - 
mr
Punjabi
 - 
pa
Tamil
 - 
ta
Telugu
 - 
te

NEW! Revised SOPs – V 2.0

  • Aerosols V 2.0
  • Analytical Method Development V 2.0
  • API Manufacturing V 2.0
  • BA-BE Studies V 2.0
  • Biosimilars V 2.0
  • Capsules V 2.0
  • Creams V 2.0
  • Elixers V 2.0
  • Gels V 2.0
  • Injectables V 2.0
  • Ointments V 2.0
  • Raw Material Warehouse V 2.0
  • Tablet Manufacturing V2.0

New Publication: A must for All.

Copyright © 2026 SOP Guide for Pharma.

Powered by PressBook WordPress theme

Go to mobile version