Analytical Method Development: Gas Evolution Reaction Method – V 2.0

Posted on By

Analytical Method Development: Gas Evolution Reaction Method – V 2.0

SOP for Gas Evolution Reaction-Based Analytical Method in AMD Laboratory


Department Analytical Method Development
SOP No. SOP/AMD/061/2025
Supersedes SOP/AMD/061/2022
Page No. Page 1 of 14
Issue Date 19/05/2025
Effective Date 20/05/2025
Review Date 19/05/2026

1. Purpose

The purpose of this SOP is to establish a procedure for the development and validation of analytical methods based on gas evolution reactions. These methods involve quantification of analytes that release a measurable gas (e.g., CO2, O2, H2) as part of their chemical reaction with specific reagents.

2. Scope

This SOP is applicable to the Analytical Method Development (AMD) laboratory and covers classical chemical methods that rely on gas evolution (e.g., carbonate determination via CO2 evolution, peroxide determination by O2 release) for analysis of raw materials, intermediates, and drug products.

3. Responsibilities

  • Analytical Chemist: Executes method development trials, prepares reaction vessels, performs measurements, and documents observations.
  • Reviewer: Verifies calculations, consistency of results, and ensures the accuracy of validation records.
  • QA Officer: Ensures adherence to GMP principles and verifies documentation practices.
  • Head – AMD: Reviews and approves validated methods for official use.

4. Accountability

The Head of AMD is accountable for ensuring that all gas evolution methods developed are scientifically justified, properly validated, and regulatory compliant.

See also  Analytical Method Development: UV Spectrophotometric Method Development - V 2.0

5. Procedure

5.1 Method Selection and Principles

  1. Select suitable gas evolution reaction based on analyte functionality. Examples:
    • Sodium bicarbonate/carbonate → CO2 upon acid addition
    • Peroxides → O2 evolution with potassium iodide
    • Hydrazine or metal hydrides → H2 release in aqueous medium
  2. Detection may be gravimetric (absorption in lime), volumetric (displacement), or titrimetric (back-titration after gas trapping).
  3. Document rationale in Annexure-1: Method Selection Justification Log.

5.2 Apparatus and Setup

  1. Use suitable reaction vessels like Kjeldahl flasks, gas burettes, or closed titration apparatus fitted with gas traps (e.g., Ba(OH)2 or NaOH).
  2. Ensure all apparatus is airtight and fitted with drying tubes if required.
  3. For volumetric gas measurement, calibrate gas burette using known gas volume (e.g., atmospheric pressure water displacement method).
  4. Document apparatus setup in Annexure-2: Equipment Preparation Log.

5.3 Sample Preparation

  1. Weigh an accurate quantity of sample containing the analyte (e.g., 250 mg sodium bicarbonate).
  2. Dissolve or suspend in distilled water if required.
  3. Record sample weight and preparation in Annexure-3: Sample Preparation Log.

5.4 Reaction and Gas Collection

  1. Place the prepared sample in the reaction chamber.
  2. Add excess standardized reagent (e.g., HCl for carbonate analysis) through dropping funnel or septum port.
  3. Allow gas to evolve and capture it in a connected gas absorption tube or volume displacement chamber.
  4. Continue reaction until no further gas bubbles are visible.
  5. For gravimetric methods, weigh the BaCO3 formed from CO2 in Ba(OH)2.
  6. For volumetric methods, note the displaced volume in burette and correct for temperature and pressure.
  7. Record all reaction observations in Annexure-4: Gas Evolution Log.
See also  Analytical Method Development: Validation-Readiness Evaluation of Developed Methods - V 2.0

5.5 Calculation

For carbonate determination by CO2 evolution (titration method):

% Carbonate = (V × N × 0.060 × 100) / W
Where:
V = Volume of HCl consumed (mL)
N = Normality of HCl
W = Weight of sample (g)
0.060 = Equivalent weight of carbonate per mL N HCl

For gravimetric gas capture:

% Analyte = (Weight of precipitate × Conversion Factor × 100) / Sample Weight

5.6 Method Optimization

  1. Optimize reaction conditions such as:
    • Acid concentration and volume
    • Reaction temperature (room temp vs. heating)
    • Rate of reagent addition to control foaming or violent reactions
  2. Ensure complete gas capture by verifying plateau in evolution volume.
  3. Perform duplicate trials to verify reproducibility.
  4. Document outcomes in Annexure-5: Method Optimization Report.

5.7 Method Validation

  1. Specificity: Use placebo matrices and excipient blanks to confirm absence of interfering gases.
  2. Precision: Intra- and inter-day precision RSD ≤ 2.0% for six replicates.
  3. Accuracy: Spike recovery at 80%, 100%, and 120% of target analyte level should be 98–102%.
  4. Linearity: Prepare samples across 50–150% range and plot vs. gas volume evolved or titration volume.
  5. Robustness: Test method sensitivity to variations in temperature, acid concentration, and reaction time.
  6. Summarize all findings in Annexure-6: Validation Summary Report.

6. Abbreviations

  • SOP: Standard Operating Procedure
  • AMD: Analytical Method Development
  • RSD: Relative Standard Deviation
  • CO2: Carbon Dioxide
  • HCl: Hydrochloric Acid

7. Documents

  1. Method Selection Justification Log – Annexure-1
  2. Equipment Preparation Log – Annexure-2
  3. Sample Preparation Log – Annexure-3
  4. Gas Evolution Log – Annexure-4
  5. Method Optimization Report – Annexure-5
  6. Validation Summary Report – Annexure-6
See also  Analytical Method Development: Preparation of Method Development Report - V 2.0

8. References

  • USP General Chapters <541>, <721> – Titrimetry and Volumetric Analysis
  • IP Appendix 3.4 – Carbonates and Bicarbonates
  • ICH Q2(R1) – Validation of Analytical Procedures
  • AOAC Methods for Gas Evolution Analysis

9. SOP Version

Version: 2.0

10. Approval Section

Prepared By Checked By Approved By
Signature
Date
Name
Designation
Department

11. Annexures

Annexure-1: Method Selection Justification Log

Analyte Gas Evolved Detection Method Analyst
Sodium Bicarbonate CO2 Titrimetric via BaCO3 Sunita Reddy

Annexure-2: Equipment Preparation Log

Apparatus ID Calibrated On Next Due Date Checked By
Gas Burette GB-003 01/04/2025 01/10/2025 Ajay Mehra

Annexure-3: Sample Preparation Log

Sample Weight Solvent Analyst
NaHCO3 Powder 250 mg None (direct) Rajesh Kumar

Annexure-4: Gas Evolution Log

Trial Volume of HCl Used Gas Volume Evolved Reaction Time % Assay
1 25.0 mL 24.3 mL (CO2) 12 mins 99.2%

Annexure-5: Method Optimization Report

Parameter Change Applied Observation Conclusion
Acid Volume +10% Ensured full reaction Accepted

Annexure-6: Validation Summary Report

Parameter Criteria Result Status
Accuracy 98–102% 99.4% Pass
Precision RSD ≤ 2.0% 0.78% Pass
Linearity R² ≥ 0.999 0.9992 Pass

Revision History:

Revision Date Revision No. Details Reason Approved By
04/05/2025 2.0 Added validation section and expanded gas detection modalities Annual SOP Review
Analytical Method Development V 2.0 Tags:Analytical Method Development SOP, SOP for analytical calculations, SOP for analytical documentation, SOP for analytical instrument calibration, SOP for analytical instrument qualification, SOP for analytical method change control, SOP for analytical method deviation handling, SOP for analytical method documentation practices, SOP for analytical method lifecycle management, SOP for analytical method optimization, SOP for analytical method risk assessment, SOP for analytical method training and competency, SOP for analytical method transfer protocol, SOP for analytical method validation, SOP for forced degradation studies, SOP for HPLC method development, SOP for limit of detection (LOD) determination, SOP for limit of quantitation (LOQ) determination, SOP for method accuracy testing, SOP for method linearity assessment, SOP for method precision evaluation, SOP for method reproducibility, SOP for method robustness testing, SOP for method transfer, SOP for method verification, SOP for qualification of working standards, SOP for reference standard handling, SOP for specificity testing in analytical methods, SOP for stability indicating methods, SOP for system suitability testing

Post navigation

Previous Post: Aerosol: SOP for Documenting Utility Validation Data – V 2.0

Standard Operating Procedures V 1.0

  • Aerosols
  • Analytical Method Development
  • Bioequivalence Bioavailability Study
  • Capsule Formulation
  • Clinical Studies
  • Creams
  • Data Integrity
  • Dental Dosage Forms
  • Drug Discovery
  • Environment, Health and Safety
  • Formulation Development
  • Gels
  • Good Distribution Practice
  • Good Warehousing Practices
  • In-Process Control
  • Injectables
  • Liquid Orals
  • Liposome and Emulsion Formulations
  • Lotions
  • Lyophilized Products
  • Maintenance Dept.
  • Medical Devices
  • Metered-Dose Inhaler
  • Microbiology Testing
  • Nanoparticle Formulation
  • Nasal Spray Formulations
  • Nebulizers
  • Ocular (Eye) Dosage Forms
  • Ointments
  • Otic (Ear) Dosage Forms
  • Pharmacovigilance
  • Powder & Granules
  • Purchase Departments
  • Quality Assurance
  • Quality Control
  • Raw Material Stores
  • Regulatory Affairs
  • Tablet Manufacturing
  • Rectal Dosage Forms
  • Transdermal Patches
  • Vaginal Dosage Forms
  • Validations and Qualifications

Read SOPs in your Language:

 - 
Bengali
 - 
bn
English
 - 
en
Gujarati
 - 
gu
Hindi
 - 
hi
Malayalam
 - 
ml
Marathi
 - 
mr
Punjabi
 - 
pa
Tamil
 - 
ta
Telugu
 - 
te

NEW! Revised SOPs – V 2.0

  • Aerosols V 2.0
  • Analytical Method Development V 2.0
  • API Manufacturing V 2.0
  • BA-BE Studies V 2.0
  • Biosimilars V 2.0
  • Capsules V 2.0
  • Creams V 2.0
  • Elixers V 2.0
  • Ointments V 2.0
  • Raw Material Warehouse V 2.0
  • Tablet Manufacturing V2.0

New Publication: A must for All.

Copyright © 2025 SOP Guide for Pharma.

Powered by PressBook WordPress theme

Go to mobile version