Analytical Method Development: Flame Test Method Development – V 2.0

Posted on By

Analytical Method Development: Flame Test Method Development – V 2.0

SOP for Flame Test Method Development in Analytical Method Development Laboratory


Department Analytical Method Development
SOP No. SOP/AMD/063/2025
Supersedes SOP/AMD/063/2022
Page No. Page 1 of 14
Issue Date 19/05/2025
Effective Date 20/05/2025
Review Date 19/05/2026

1. Purpose

This SOP outlines the procedure for developing and validating flame test methods for the qualitative identification of metal ions in pharmaceutical materials by observing characteristic color emissions upon combustion.

2. Scope

This SOP applies to the Analytical Method Development (AMD) department and is intended for the identification of alkali and alkaline earth metals such as sodium, potassium, calcium, lithium, and barium in raw materials and finished drug substances.

3. Responsibilities

  • Analytical Chemist: Prepares samples and standards, performs flame tests, and documents observations.
  • Reviewer: Ensures accuracy of color observation records and proper documentation.
  • QA Officer: Confirms method compliance with GMP and GLP guidelines.
  • Head – AMD: Approves the developed method for routine use and regulatory support.

4. Accountability

The Head of AMD is accountable for the approval, integrity, and reliability of all flame test methods used in the identification of inorganic ions in pharmaceutical substances.

See also  Analytical Method Development: Moisture Analysis Method for Hygroscopic APIs - V 2.0

5. Procedure

5.1 Principle of Flame Test

  1. Flame tests are based on the excitation of electrons in metal ions by heat energy, which release visible light of specific wavelengths upon returning to their ground state.
  2. Each element emits a distinct flame color, allowing qualitative identification.
  3. The intensity and clarity of the flame color are influenced by:
    • Purity of sample
    • Presence of masking agents or impurities
    • Type of flame used (oxidizing/reducing)

5.2 Apparatus and Reagents

  1. Apparatus:
    • Bunsen burner or spirit lamp
    • Platinum or nichrome wire loop
    • Porcelain crucibles or watch glasses
    • UV-protective glasses for accurate flame color observation
  2. Reagents:
    • Concentrated hydrochloric acid (for cleaning and preparing volatile salts)
    • Standard solutions of known metal ions (Na+, K+, Ca2+, etc.)
  3. Record all materials and instruments in Annexure-1: Apparatus and Reagent Log.

5.3 Preparation of Standard and Sample

  1. Prepare 1% (w/v) solutions of reference standards in deionized water or dilute HCl.
  2. Dissolve test sample in minimal volume of water or HCl to form a clear solution.
  3. Clean wire loop by dipping in HCl and holding in flame until no color is observed.
  4. Document all solution details in Annexure-2: Sample and Standard Prep Log.

5.4 Performing the Flame Test

  1. Dip cleaned loop into sample or standard solution.
  2. Introduce the loop into the hottest part of a non-luminous Bunsen flame.
  3. Observe the flame color and compare with known standards:
    • Sodium – Yellow
    • Potassium – Violet
    • Calcium – Brick red
    • Lithium – Crimson red
    • Barium – Pale green
  4. For confirmation, use cobalt glass to filter overlapping emissions (e.g., Na in presence of K).
  5. Document flame color, duration, and other observations in Annexure-3: Flame Test Observation Log.
See also  Analytical Method Development: Development of Test Procedures for Formulations - V 2.0

5.5 Safety Precautions

  1. Use flame-resistant gloves and UV-protective goggles during testing.
  2. Handle concentrated HCl under fume hood.
  3. Ensure open flame sources are used in flame-proof enclosures where applicable.

5.6 Method Optimization

  1. Evaluate optimal sample concentration and solvent system.
  2. Compare loop types (platinum vs nichrome) for clarity of emission.
  3. Assess interference by excipients and remove using sample purification (e.g., ion-exchange or filtration).
  4. Document improvements in Annexure-4: Optimization Report.

5.7 Method Validation

  1. Specificity: Confirm that each metal ion produces a distinct color not reproducible by others.
  2. Precision: Perform triplicate tests for each ion and evaluate observer agreement.
  3. Robustness: Evaluate reproducibility under different flame intensities and loop materials.
  4. Limit of Detection (LOD): Determine minimum detectable concentration visually.
  5. Summarize findings in Annexure-5: Validation Summary.

6. Abbreviations

  • SOP: Standard Operating Procedure
  • AMD: Analytical Method Development
  • LOD: Limit of Detection
  • HCl: Hydrochloric Acid

7. Documents

  1. Apparatus and Reagent Log – Annexure-1
  2. Sample and Standard Prep Log – Annexure-2
  3. Flame Test Observation Log – Annexure-3
  4. Optimization Report – Annexure-4
  5. Validation Summary – Annexure-5
See also  Analytical Method Development: Qualification of Method Development Instruments - V 2.0

8. References

  • USP General Chapter <197> – Spectroscopic Identification
  • IP Appendix – Identification of Ions by Flame Tests
  • ICH Q2(R1) – Validation of Analytical Procedures

9. SOP Version

Version: 2.0

10. Approval Section

Prepared By Checked By Approved By
Signature
Date
Name
Designation
Department

11. Annexures

Annexure-1: Apparatus and Reagent Log

Item ID/Batch No. Preparation/Verification Date Checked By
Bunsen Burner BB-011 10/05/2025 Ajay Mehra

Annexure-2: Sample and Standard Prep Log

Material Concentration Solvent Used Prepared By
Sodium Standard 1% w/v Distilled Water Sunita Reddy

Annexure-3: Flame Test Observation Log

Sample Observed Flame Color Reference Color Status Observer
Sample A Yellow Sodium Confirmed Rajesh Kumar

Annexure-4: Optimization Report

Parameter Tested Variation Observation Conclusion
Loop Material Nichrome vs Platinum Brighter color with Platinum Platinum preferred

Annexure-5: Validation Summary

Parameter Acceptance Criteria Result Status
Specificity Distinct flame color Confirmed Pass
Precision Reproducibility in 3 trials Consistent Pass
LOD 0.01% solution Detected Pass

Revision History:

Revision Date Revision No. Details Reason Approved By
04/05/2025 2.0 Included optimization of loop material and validation section Annual SOP Update
Analytical Method Development V 2.0 Tags:Analytical Method Development SOP, SOP for analytical calculations, SOP for analytical documentation, SOP for analytical instrument calibration, SOP for analytical instrument qualification, SOP for analytical method change control, SOP for analytical method deviation handling, SOP for analytical method documentation practices, SOP for analytical method lifecycle management, SOP for analytical method optimization, SOP for analytical method risk assessment, SOP for analytical method training and competency, SOP for analytical method transfer protocol, SOP for analytical method validation, SOP for forced degradation studies, SOP for HPLC method development, SOP for limit of detection (LOD) determination, SOP for limit of quantitation (LOQ) determination, SOP for method accuracy testing, SOP for method linearity assessment, SOP for method precision evaluation, SOP for method reproducibility, SOP for method robustness testing, SOP for method transfer, SOP for method verification, SOP for qualification of working standards, SOP for reference standard handling, SOP for specificity testing in analytical methods, SOP for stability indicating methods, SOP for system suitability testing

Post navigation

Previous Post: Elixir Department: SOP for Maintaining Volume Adjustments – V 2.0
Next Post: BA-BE Studies: SOP for Emergency Medical Resuscitation Kit Use – V 2.0

Standard Operating Procedures V 1.0

  • Aerosols
  • Analytical Method Development
  • Bioequivalence Bioavailability Study
  • Capsule Formulation
  • Clinical Studies
  • Creams
  • Data Integrity
  • Dental Dosage Forms
  • Drug Discovery
  • Environment, Health and Safety
  • Formulation Development
  • Gels
  • Good Distribution Practice
  • Good Warehousing Practices
  • In-Process Control
  • Injectables
  • Liquid Orals
  • Liposome and Emulsion Formulations
  • Lotions
  • Lyophilized Products
  • Maintenance Dept.
  • Medical Devices
  • Metered-Dose Inhaler
  • Microbiology Testing
  • Nanoparticle Formulation
  • Nasal Spray Formulations
  • Nebulizers
  • Ocular (Eye) Dosage Forms
  • Ointments
  • Otic (Ear) Dosage Forms
  • Pharmacovigilance
  • Powder & Granules
  • Purchase Departments
  • Quality Assurance
  • Quality Control
  • Raw Material Stores
  • Regulatory Affairs
  • Tablet Manufacturing
  • Rectal Dosage Forms
  • Transdermal Patches
  • Vaginal Dosage Forms
  • Validations and Qualifications

Read SOPs in your Language:

 - 
Bengali
 - 
bn
English
 - 
en
Gujarati
 - 
gu
Hindi
 - 
hi
Malayalam
 - 
ml
Marathi
 - 
mr
Punjabi
 - 
pa
Tamil
 - 
ta
Telugu
 - 
te

NEW! Revised SOPs – V 2.0

  • Aerosols V 2.0
  • Analytical Method Development V 2.0
  • API Manufacturing V 2.0
  • BA-BE Studies V 2.0
  • Biosimilars V 2.0
  • Capsules V 2.0
  • Creams V 2.0
  • Elixers V 2.0
  • Ointments V 2.0
  • Raw Material Warehouse V 2.0
  • Tablet Manufacturing V2.0

New Publication: A must for All.

Copyright © 2025 SOP Guide for Pharma.

Powered by PressBook WordPress theme

Go to mobile version